Air-Conditioner Error Code List - Sharp Global
Maybe your like
- Please unplug the AC code and perform following step.
- - Please check the air-filter dirt.
- - Please check if there are nothing covering the wind inlet/outlet of the indoor/outdoor unit.
- - Please check if there are any papers, leafs or other dusts clogging the alminum fin of the outdoor unit.
- After more than one minute past, please plug the AC code again and start operation.If the error still occurs, please contact customer service and tell the error number and the phenomenon.
- For North American air conditioner models, contact your local installer.
| Phone number | URL | |
|---|---|---|
| Indonesia | 0800-1-225588 | https://www.id.sharp/contact_us |
| Malaysia | 1800-888-678 | https://my.sharp/contact_us |
| Philippines | 1-800-1-888-4952 | https://ph.sharp/contact_us/ |
| Singapore | 64195222 | https://sg.sharp/contact_us |
| Thailand | 02-855-8888 | https://www.th.sharp/en/contact_us |
| Vietnam | 1-800-1599 | https://vn.sharp/lien-he |
| India | 0120 - 3358886 | http://in.sharp/b2b/contact-us/ |
| Bangladesh | 961-000-1010 | https://esquireelectronicsltd.com/contact-service-center/ |
| Error Code | Content of Diagnosis |
|---|---|
| 1-0 | Heat exchanger thermistor short circuit error |
| 1-1 | Outdoor temperature thermistor short circuit error |
| 1-2 | Suction thermistor short circuit error |
| 1-3 | 2-way valve thermistor short circuit error |
| 1-4 | Heat sink thermistor short circuit error |
| 2-0 | Compressor high temperature error |
| 2-1 | Compressor discharge overheat |
| 2-2 | Outdoor unit heat exchanger overheat |
| 2-3 | Indoor unit heat exchanger overheat |
| 2-4 | IPM high temperature error |
| 2-5 | IPM high temperature error |
| 3-0 | Temporary stop due to dehumidifying operation |
| 5-0 | Heat exchanger thermistor open circuit error |
| 5-1 | Outdoor temperature thermistor open circuit error |
| 5-2 | Suction thermistor open circuit error |
| 5-3 | 2-way valve thermistor open circuit error |
| 5-4 | Discharge thermistor open circuit error |
| 5-5 | Heat sink thermistor open circuit error |
| 6-0 | DC over current error |
| 6-1 | IPM pin level error |
| 7-0 | AC over current error |
| 7-1 | AC current error when OFF |
| 7-2 | AC maximum current error |
| 7-3 | AC current deficiency error |
| 9-0 | Thermistor installation error or 4-way valve error |
| 9-3 | Compressor torque control error |
| 9-4 | 4 way valve error or Gas leak error |
| 9-5 | 2-way valve and 3-way valve close error |
| 9-6 | Solenoid valve error |
| 10-0 | EEPROM (Outdoor) data error |
| 10-1 | EEPROM (Outdoor) data error |
| 10-2 | CPU (Outdoor) RAM data error |
| 11-0 | Outdoor unit DC fan rotation error |
| 11-1 | Outdoor unit DC fan driver IC error |
| 11-2 | Outdoor unit DC fan lock error |
| 11-3 | Detection error of DC fan negative rotation before compressor is driven |
| 11-4 | Detection error of inverter current for DC fan |
| 11-5 | Outdoor unit DC fan open connector error |
| 12-0 | Thermal fuse error in terminal board (for power supply) |
| 13-0 | Compressor startup error |
| 13-1 | Compressor rotation error (At 120°energizing) |
| 13-2 | Compressor rotation error (At 180°energizing) |
| 13-3 | Detection error of inverter current |
| 14-0 | PAM over voltage error |
| 14-1 | PAM clock error |
| 14-2 | PAM under voltage error |
| 14-4 | PFC Module error |
| 17-0 | Serial open-circuit |
| 18-0 | Serial short-circuit |
| 18-1 | Serial erroneous wiring |
| 18-2 | High speed serial communication error |
| 19-0 | Indoor unit fan error |
| 19-1 | Indoor unit fan error - Low rotation |
| 19-2 | Indoor unit fan error - Rotation during stop |
| 19-3 | Indoor unit fan error - High rotation |
| 20-0 | EEPROM data error |
| 20-1 | External EEPROM initial data reading error |
| 20-2 | External EEPROM verify error |
| 20-3 | External EEPROM communication error |
| 21-0 | Incomplete closing of louver cover or louver closing lever |
| 22-0 | Plasmacluster connecting error |
| 22-1 | Lock On Sensor error |
| 22-2 | Over time of accumulated plasmacluster operation time |
| 23-0 | Wrong connect to 200V AC |
| 23-1 | Incorrect voltage during operation |
| 24-0 | Wireless lan module communication error |
| 24-1 | Connecting error with wireless lan router |
| 24-2 | Internet condition error |
| 24-3 | Connecting error with server |
| 25-1 | AC clock error |
| 26-1 | Indoor unit room temperature thermistor |
| 26-2 | Indoor unit pipe temperature thermistor |
| 26-3 | Gas sensor error |
| 26-4 | Dust sensor error |
| 28-0 | Initial error filter cleaning operation |
| 28-1 | Error during filter cleaning operation |
| 28-2 | Incomplete closing of open panel or front panel, or air filter installation error |
| 28-3 | Filter detachment error |
| 29-0 | Panel cannot open |
| 29-1 | Panel cannot close |
| 31-0 | Sub microcomputer error |
| 31-6 | Sub microcomputer error |
| 31-7 | Sub microcomputer error |
Tag » Codigo U1-01 Sharp
-
Error Codes > Sharp > MXM264N > Code U1-01 - PrintCopy .info
-
Error Codes > Sharp > MXC301 > Code U1-01 - PrintCopy .info
-
Comment Corriger Le Code Erreur U1-01 Avec Sharp MX ... - YouTube
-
SHARP MXN264N ERROR CODE U1-01.HOW TO SOLVE IT - Fixya
-
Error Code MX2640 U1-01 - Copytechnet
-
Sharp MX4112N Error Code U1-01
-
Sharp MXC300A Error Codes
-
I Have A Sharp SF-7900 Copier With An Error Code "U1". Machine
-
Details Of Trouble Codes - Sharp AL-2051 Service Manual [Page 108]
-
Sharp AR-M550N Trouble Error Codes - Manualzz
-
MX-2614N/MX-3114N Error Code List | CORONA TECHNICAL
-
Sharp Error Code H5-01 Reset · PDF FileTrouble Error Codes
-
Codes Erreur SHARP - Sharp Photocopieur
-
[PDF] SHARP TROUBLE & ERROR CODES AR-M550N, AR-M550U, AR ...