Australasia Taking care of our customers in Australia and New Zealand Americas Taking care of our customers in America, Canada, Central & South America South East Asia Taking care of our customers in Southeast and East Asia China Taking care of our customers in China +61 (0) 7 3256 0534 About Contact News & Blogs Events site logo +61 (0) 7 3256 0534
  • Products Products View all Products High Voltage Solutions Low Voltage Solutions Software Solutions
  • Services Services View all Services Condition Assessment of Electrical Assets Network Strategy and Transformation Asset Management Training
  • Sectors
  • Resources
  • More
    • More
    • About
    • Contact
    • News & Blogs
    • Events
  • Search
Ensuring Reliable Switchgear Performance with Circuit Breaker Testing
  1. Home
  2. Services
  3. Condition Assessment of Electrical Assets
  4. Switchgear Condition Assessment
  5. Circuit Breaker Testing

Circuit Breaker Testing

Circuit Breaker Testing (also known as ‘Trip Profiling’) is essential for ensuring the safety and reliability of the circuit breaker, a key link in the power asset chain. This testing is crucial for maintaining electrical safety and preventing electrical shock.

  • Quick and easy to perform on-site
  • Circuits can be tested on or offload
  • Tests performance of whole tripping cycle
  • Tests overall timing of the tripping system
  • Identifies need for maintenance

Circuit breakers perform a vital role in protecting expensive equipment from damage through faults. They are designed to protect electrical circuits from damage caused by short circuits and fault conditions. Testing the performance of your circuit breakers regularly is, therefore, an essential and cost-effective part of any maintenance strategy, ensuring both circuit protection and electrical safety.

  circuit breaker testing

EA Technology’s circuit breaker testing service consists of two tests to assess the condition and performance of the tripping system:

Circuit Breaker Trip Test

By analysing the current consumed by the trip coil during the circuit breaker’s operation, it is possible to determine whether there are mechanical or electrical issues present. In many cases, such issues can be localised to aid in finding the root cause. Monitoring the tripping supply’s voltage during the operation can detect issues arising with tripping batteries.

Secondary Injection of Overcurrent and Earth Fault Relays

Proper coordination of the protection schemes on a network is essential to minimise the disruption caused by a fault. Secondary injection testing ensures that protection relays operate as intended, safeguarding the electrical circuit.

In addition to these primary tests, dynamic contact resistance tests and primary injection tests can provide further insights into the condition and reliability of circuit breakers. These tests are particularly important in industrial applications where the reliability of the electric power system is paramount. EA Technology also offers testing services for miniature circuit breakers and single pole breakers, ensuring comprehensive coverage of all types of protection devices.

Test your circuit breakers with us today to ensure your protection devices are functioning correctly and maintaining electrical safety.  Get in touch!

 

Image Brad Monaghan Head of Technical Services Brad Monaghan

Head of Technical Services

Brad is the Head of Services at EA Technology Australia.

With over 20 years in the energy sector, 5 of which at EA Technology, Brad has a versatile, technical skillset established through his experience with electrical distribution companies, industrial and renewables across a range of trades and field teams.

Through his early career at a DNO, Brad has a core knowledge and capability in technical, operational and test procedures within the electrical industry. He works predominantly with high voltage (HV) assets and plays a key role in condition monitoring, diagnosing and managing partial discharge defects, conducting PD surveys, training, technical support and data interpretation.

  • Email us

Related Services

Man holding an equipment - switchgear assessment

Partial Discharge Surveys

Have one of our electrical engineers perform a partial discharge (PD) survey to determine the condition of your electrical assets....

Find out more Hero Cable rating service: CRATER

Hipot Testing

Need Offline High Voltage testing for withstand or partial discharge? EA Technology has the electrical experts you need to make su...

Find out more Man doing a thermographic survey

Infrared Thermographic Surveys

Have one of our electrical engineers perform an infrared thermographic survey to determine problem areas in your electrical system...

Find out more

Safer, stronger, smarter networks

+61 (0) 7 3256 0534 [email protected] Newsletter - Sign Up
  • Products
  • Services
  • Sectors
  • Resources
  • About
  • News & Blogs
  • Events
© EA Technology Pty Ltd 2026 All Rights Reserved
  • Cookies & Privacy
  • Terms & Conditions

Tag » How To Test A Circuit Breaker