This paper discusses how data is stored in COBOL comp-3, ... If the size of the field is specified as an even number of digits, as in "PIC S9(6) comp-3.
View more »
This exit DATEFBE processes a date field defined as PIC S9(9) COMP-3. There are 6 significant digits in the date, which has a picture string of YYMMDD.
View more »
9: One or more numeric character positions; S: One operational sign ... COMPUTATIONAL-3 or COMP-3 (internal decimal): This is the equivalent of ...
View more »
1234, PIC S9(5) COMP, 00 01 02 03 04 0B ... The RM/COBOL system represents COMP-3 data in packed decimal format with the ... 1234, PIC 9(5) COMP-3, 00 23 4F.
View more »
The RM/COBOL system represents COMP-3 data in packed decimal format with the least significant half-byte holding the ... 1234, PIC S9(5) COMP-3, 00 23 4F.
View more »
As you were told, V is implied Decimal point. When you display, '.'(dot) won't print. try to move COMP-3 values to other variable with PIC ...
View more »
COBOL Programming: Is this possible to move an alphanumeric X(6)to s9(5)comp-3 value If we can't then how can i move this 6 byte value to...
View more »
Example : 01 WS--DS-HDR-LEN PIC S9(02) COMP.Which occupies 2 bytes and data stored as Pure binary format internally. Data name length Length in COBOL 9(01) to 9 ...
View more »
01 COMP3-NM2 PIC S9(04) USAGE COMP-3 VALUE '2561'. PROCEDURE DIVISION. DISPLAY 'COMPUTATION-3..'. DISPLAY 'COMPUTATION3 - NUMERIC [9(04)-> 2 BYTES]'.
View more »
Similar questions have been answered multiple times already on Stack overflow. For s9(5)V9(4) comp-3, 123.45 is represented in byte format ...
View more »
27 sept. 2021 · Difference between COMP and COMP3 ; Example: 02 CompVariable PIC 9 USAGE IS COMP. 02 CompVariable1 PIC S9(5) USAGE IS COMP. Example: 02 Variable ...
View more »
All CA IDMS data types can be supported in a COBOL program. This table shows types of COBOL ... PIC S9(p-s)V9(s) USAGE COMP-3. DECIMAL(p,s) ... (where n>9).
View more »
(n/2+1)(when the number is even) for instance pic s9(4) comp-3 ,so ... is in my COBOL program one variable is declared as S9(9)V99 COMP-3.
View more »
5 mars 2009 · Valeur "123456" dans une zone signée de 7 chiffres au format packé (PIC S9(7) COMP-3 --> "01.23.45.6F"). Cette zone n'occupe en fait que 4 ...