10 avr. 2009
View more »
The maximum length of a computational item is 18 decimal digits, ... digits 0 through 9, plus a sign, representing a value not exceeding 18 decimal digits.
View more »
Hi,Could anyone tell me what is the maximum value that can be stored in s9(04) comp and s9(09) comp and also the method to it find out? Moving Alphanumeric to COMP - IBM Cobol - IBM Mainframe Forum how to the a binary field PIC S9(4) COMP. - IBM Cobol Representation of COMP,COMP-1 and COMP-2 in sequential file Autres résultats sur www.ibmmainframeforum.com
View more »
Is this the same for comp S9(8/9) and are those values different? ... COBOL PIC 9(9) COMP max = 999,999,999. COBOL NATIVE-4 max = ... move s9(4) to s9(4) comp problem - COBOL General discussion Byte size of COMP field - COBOL General discussion - Tek-Tips What is the largest numeric value stored in pic s(5)v999 - Tek-Tips Moving PIC S9(15)V9(02) COMP-3 to output - Tek-Tips Autres résultats sur www.tek-tips.com
View more »
S9(9)V99 comp-3 can hold values in the range of +999,999,999.99 to -999,999,999.99. Each 2 digits takes up 1 byte of a packed decimal, ...
View more »
COMP PIC S99 - (signed) can contain -32768 to +32767. ... Remembering that PROGA has a maximum value of 9999, and noting that 19998 fits ...
View more »
6 oct. 2004 · Max value possible in COMP field ?? ... It depends on the compiler, but remember that a pic 9(4) comp ... 01 WS-ACCUM-P PIC S9(8) COMP.
View more »
How many bytes does the S(8) comp field occupy and its maximum value in COBOL?
View more »
On most platforms, the maximum length of a CHARF value is 65535 (64K) bytes. ... FLOAT relates to the COBOL datatypes COMP-1 (4-byte floating point) and ...
View more »
This format places the highest-order part of the value in the leftmost ... For example, a PIC S9(9) COMP-5 data item is equivalent to a 32-bit binary word ...
View more »
The focus is on the usage of the COBOL PIC 9 COMP syntax. ... Since the binary format stores the number as an actual binary value the field will only be two ...
View more »
26 sept. 2011 · If compiler option ARITH is EXTEND, then can move maximum value of 31-9's to COMP-5. E.g 01 ws-a PIC S9(10) COMP-5.
View more »
Zoned decimal, PIC S9( n )[V9( m )], N n [, m ], Unpacked decimal, 2,4,8. Packed decimal, PIC 9( n ) [V9( m )] COMP[UTATIONAL]-3 ...
View more »
Have you ever thought/checked/observed what maximum value PIC S9(0N) COMP (N ... Similarly, PIC S9(09) COMP, even though seemingly shows to have 9 digits ...