Digital Image Correlation (DIC)

Digital Image Correlation (DIC) effectively tracks the movement of the naturally occurring, or applied surface pattern during the test or experiment. This is done by analyzing the displacement of the patterns within discretized subsets or facet elements of the whole image. The maximum correlation in each window corresponds to the displacement, and this gives the vector length and direction for each window. Advanced algorithms use multi-pass processing, window deformation, and the possibility of non-square subsets to maximize the sub-pixel accuracy.

no-img The user acquires a series of images during a material testing experiment, with the first image normally being the case of zero applied load. With standard single camera or stereoscopic multi camera setups, 2D in-plane deformation or full 3D surface measurements are achieved. Local derivative calculations give the strain tensors across the entire surface, and a standard feature of StrainMaster is the ability to place a virtual strain gauge anywhere on the sample surface after the test, giving incredibly accurate strain data. Digital Volume Correlation (DVC)

Digital Volume Correlation (DVC) is a novel technique for full 3D strain and deformation measurements. The technique imports volume images of the component in reference and deformed states and is able to calculate the full 3D displacement and strain map. Images are typically acquired from X-ray Computed Tomography (X-ray CT) systems, but can equally be obtained by Magnetic Resonance Imaging (MRI) systems for biological subjects, or via optical tomography for transparent media; for which LaVision offer our tomographic reconstruction algorithms as an add-on. DVC is a powerful non-intrusive technique for the identification of sub-surface material deformation and is capable of identifying defects, discontinuities or other material characteristics. In order for Digital Volume Correlation to be successful the volume images must contain a random pattern. That random pattern is seen as changes in local contrast. In the case of X-ray CT scans the pattern will be produced by changes in material density such as air voids in concrete, or particles of different material type within the main body matrix, such as Digital Volume Correlation (DVC) tin particles distributed in an aluminium powder. The volume image is sub-divided into interrogation volumes within which robust and highly accurate algorithms calculate the displacement of the pattern, which represent the material shift. Digital Volume Correlation is capable of yielding over one million displacement vectors per volume image pair.

Related Products

  • StrainMasterDeformation and Strain
  •  Visit us on Facebook
  •  Visit us on YouTube
  •  Visit us on LinkedIn
  • RMA Policy
  • |
  • Terms & Conditions
  • |
  • Terms & Conditions of Purchase
  • |
  • Imprint
  • |
  • Privacy Policy
  • |
  • Code of Conduct
  • |
  • Cookie settings
  • |
LAVISION - we count on photons
  • English
  • Deutsch
  • Français
  • Contact
  • Company
  • News & Events
  • Careers
  • Contact
  • Support
  • Login
  • Products
    • FlowMaster
      • Pressure from PIV
      • 2D-/ Stereo PIV
      • Tomographic PIV
      • Time-Resolved PIV
      • PTV / Shake-the-Box
      • Fluid-Structure Interaction
      • Thermographic PIV
      • Micro-PIV
      • Underwater PIV
      • Endoscopic PIV
      • Educational PIV
      • PIV System Components
      • Laser Doppler Velocimetry
    • FluidMaster
      • Mixing Fluids
      • Thermal Flows
      • Multiphase Flows
      • Scalar Imaging Software
    • FlowBOS
      • BOS
      • Hydrogen Visualization
    • FlameMaster
      • Inspex
      • Multifunctional
      • Raman
      • Tunable LIF
      • High-Speed
      • 3D Flame Imaging
      • PIV in Flames
      • Multi-Parameter Imaging
      • Soot Sensor
      • Hydrogen Combustion
      • Ammonia Combustion
      • Scalar Imaging Software
    • Automotive Imaging / EngineMaster
      • Glass-SFR inspex
      • Laser Imaging in Engines
      • Inspex
      • ICOS
      • Endoscopes
      • Aerodynamic Testing
      • Materials Testing
    • SprayMaster
      • Spray Geometry
      • Inspex
      • Laser Imaging in Sprays
      • Dense Sprays, SLIPI
      • PDI
    • ParticleMaster
      • Inspex
      • Inspex online
      • Shadow Imaging
    • StrainMaster
      • 2D-/ Stereo DIC
      • DVC
      • Systems
      • System Components
    • Imaging Inspection Systems
      • Spray Imaging
      • Particle and Droplet Imaging
    • Cameras and more
      • Cameras for PIV
      • Cameras for DIC
      • Intensified Cameras
      • High-Speed Cameras
      • Programmable Timing Unit PTU
      • Camera- and Illumination Endoscopes
    • DaVis Software
    • Sensor Systems
      • Optical Engine Indication - ICOS
      • Doppler Interferometer
      • Soot Sensor
      • Leakage Sensor
    • Contract Measurements
  • Applications
    • Fluid Mechanics
    • Mixing & Thermal Flows
    • Gas Flow Imaging
    • Industrial Process Imaging
    • Fluid-Structure Interaction
    • Materials Testing
    • Combustion
    • Automotive
    • Particle Characterization
    • Sprays
    • Sustainable Combustion
  • Techniques
    • Laser Imaging
    • PIV / PTV
    • LIF / PLIF
    • LII
    • Mie/Rayleigh/Raman
    • Shadow, IMI
    • Planar Droplet Sizing
    • LDV, PDI
    • Schlieren, BOS
    • Emission, Absorption
    • DIC, DVC
  • Download
    • Media
      • Poster
      • Webinars
      • Online-Seminar
    • Brochures
    • Flyer
    • Application Notes
    • Datasheets
    • Publications
      • Other Application Areas
    • Software
      • IRO App
      • Python Add-Ons
      • Matlab Add-Ons
      • Tecplot Add-Ons
      • DaVis Legacy Add-Ons
    • Manuals
    • Driver
      • Miscellaneous
  • Industry
LaVision EN DE FR

Tag » What Is Digital Image Correlation