Master electrician Rex Cauldwell offers some insight into the controversial topic of which way you should orient wall receptacles when wiring a circuit in a house.
By Rex Cauldwell Issue 193Q:
The outlets in my house are installed with the grounding prongs above the slots for the paired plug blades. Is this wrong?
Mary Walsh, Lawrence, KS
A:
Rex Cauldwell, a master electrician in Rocky Mount, Va., replies: There is no official right or wrong way to orient a receptacle—the National Electrical Code doesn’t specify—but you can decide by using logic and common sense. Clothes washers, refrigerators, and window air conditioners typically have cords with immediate-turn plugs. For appliances with this type of plug, orient the receptacle so that the plug inserts without having to loop over itself. Otherwise, the downward pull of the cord tends to tug the plug from the receptacle.
For immediate-turn plugs, orient the outlet with the ground slot on the bottom.
For all other plugs, I put the grounding slot on top. If a plug is partially pulled from the receptacle, exposing the hot and neutral blades, and something metal falls on it (like a knife or a picture frame), a direct short won’t occur because the grounding pin deflects the item from the terminals.
For horizontal receptacles, place the grounding slot to the left and the wide neutral slot on top. This way, if something metal falls on the partially exposed blades, the item will hit the grounded neutral blade instead of the hot blade.
More about residential wiring:
Electrical Outlets by the Numbers – Building codes dictate specific height and spacing measurements for receptacles and switches. Learn what the most common dimensions are and why.
9 Common Wiring Mistakes and Code Violations – Some are illegal, some are dangerous, and some are both—but all are simple to avoid.
Is Your Old Wiring Safe? – Inspect the electrical panel and exposed wiring throughout your house to identify safety risks, fire hazards, and upgrade options.
From Fine Homebuilding #193
Sign up for eletters today and get the latest how-to from Fine Homebuilding, plus special offers.
Sign UpSigning you up...
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply. See all newsletters See all newsletters Previous: Should I Upgrade Ungrounded Outlets? Next: A Bad Splice Might Indicate More Problems View 10 commentsView Comments
-
jbouwer | Mar 15, 2019 06:39pm | #1 Ground pin down. The ground pin up were mainly installed in hospitals, as it was possible for a thin metallic object to fall on the live blades.
-
user-6810696 | Jan 15, 2020 05:48pm | #2 I'd be pissed if an electrician installed receptacles with the ground pin up. I would have to redo all of them.
-
davehomeimp | Apr 09, 2020 12:12am | #3 Years ago I worked for two different cousins who were electrical contractors. One installed the ground up, one installed them down. Neither could say why they did it their preferred way.i think the idea that some “metal” thing falling on a plug is a long shot and an old electricians tale. From personal experience I have seen dozens of outlets broken when cords were unplugged roughly and the ground prong was on the top. Try it. Plug a three prong plug into one mounted at 15 inches high and pull the cord in an upward direction. I would never install or recommend anyone put the ground prong up on normal lower level outlets. Plus, they look funny.
-
timmer2 | Jan 21, 2021 01:29pm | #4 This article ignores the fact that in many new homes vertical receptacles that have the ground up are switch-controlled and receptacles with the ground down are not switch-controlled.
-
ktkcad | Jan 21, 2021 02:32pm | #5 When I questioned the electrican at our world headquarters build why he installed all the outlets ground up, he jumped into a rant and spewed the line about metal object falling. In an office that might be more reasonable. I'm also wondering if babies/toddlers would be less enamored by that view rather than all the winking wide-mouth emoticons, right at their level, begging for something to be put into them. But then it might have taken another 100 years to come up with tamper proof outlets.
-
FBaldwin | Mar 21, 2021 10:42am | #6 Nope, I will continue to put the ground down. Ive never seen a metal object fall and stay connected to the plug pins. Otherwise I agree with everything Rex writes.
-
SteveHallArchitecture | May 22, 2021 04:53pm | #7 The point of ground pin down is to minimize danger when plugging in or pulling out a cord. There's only one thumb on the top where you can see the dangerous prongs. But on the bottom of a plug, you have multiple fingers which are more likely to contact one of the two unseen positive prongs, and that are more likely to contract even tighter when shocked.
-
gchdrake | Jan 27, 2022 08:59am | #8 I have no logic for why I have ALWAYS installed ground pin down (but I was trained that way) but as a result of that practice I am annoyed when I walk in a house and see it on top. As a renovator of historic homes I am constantly changing out non-grounded outlets and I have NEVER had a client ask for ground up. One reasonable excuse I have heard from ground pin up folks is that the military does it that way so they do. I have never had the opportunity to investigate that but it would be interesting to know if it is true.
-
Wranglerrick | Feb 21, 2024 10:46am | #9 Rex, Your answer is correct. The NEC does not specify directions. You picture labeling of "correct" or "incorrect" can be mis leading since either could be correct. 44 Years Electrician. 3 cycles CMP-18 dealing with Article 406. CMP-9 and 1CMP-8
-
seh0041 | Sep 30, 2024 11:00am | #10 Homeowner here. I can't tell you how irritating it is that our builder installed our bathroom and kitchen outlets horizontally, ground pin to the left. Actually, I learned from this article that one on a bathroom wall to the left is actually incorrectly installed (hot on top). Especially in the bathroom, this grates on my last nerve because the thick cord for my hair dryer is pulled backward (overlapping itself) while in use. Plus, needing a dryer, curling iron, plug-in clock, and phone charger at one outlet, I'm constantly rotating all my plugs. There are very few multi-outlets that rotate, so I tried a short extension cord surge protector, but it also gets pulled backward and is too heavy for the wall outlet (it's always sagging sideways). The kitchen situation is the same; blender, toaster oven, stand mixer, etc. to plug in/unplug all the time, with most of them being so heavy that they aren't held in well. I've been in this house for 3 years and I'm still looking for a good solution. I stumbled upon this article when looking to see how difficult it is to re-install these outlets vertically. Please keep the logical use of these outlets in mind when installing them for your customers, e.g., plugging in & unplugging multiple tools daily.
Log in or create an account to post a comment.
Sign up Log inBecome a member and get full access to FineHomebuilding.com
Wiring
Trusted, code-compliant guidance from the pros for working safely on any wiring project
View Project Guide
View All Project Guides »
Become a member and get unlimited site access, including the Wiring Project Guide.
Start Free Trial
Working with Electricity
- Basics
- Safety
- Troubleshooting and Upgrades
Tools and Materials
- Electrical Tools
- Electrical Boxes
- Cables and Wires
Receptacles and Switches
- Materials
- Wiring Receptacles
- Wiring Switches
Lights and Fans
- Lighting Design
- Installing Lights
- Fans
Rough-In
- Planning
- Installing Electrical Boxes
- Running Cable
- Retrofit Work
- Making Connections in Boxes
- Electrical Conduit
Outdoor Wiring
- Basics
- Outlets
- Installing Lighting
Panels and Subpanels
- Understanding Panels
- Circuits
- Installing a Subpanel
Fine Home Building
Newsletter Sign-up
-
Fine Homebuilding
Home building tips, offers, and expert advice in your inbox.
-
Green Building Advisor
Building science and energy efficiency advice, plus special offers, in your inbox.
-
Old House Journal
Repair, renovation, and restoration tips, plus special offers, in your inbox.
Signing you up...
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply. See all newslettersFollow
-
Fine Homebuilding
Dig into cutting-edge approaches and decades of proven solutions with total access to our experts and tradespeople.
Start Free Trial Now- X
-
GBA Prime
Get instant access to the latest developments in green building, research, and reports from the field.
Start Free Trial Now- YouTube
-
Old House Journal
Learn how to restore, repair, update, and decorate your home.
Subscribe Now- X
Membership & Magazine
- Online Archive
- Start Free Trial
- Magazine Subscription
- Magazine Renewal
- Gift a Subscription
- Customer Support
- Privacy Preferences
- About
- Contact
- Advertise
- Careers
- Terms of Service
- Site Map
- Do not sell or share my information
- Privacy Policy
- Accessibility
- California Privacy Rights
© 2025 Active Interest Media. All rights reserved.
Fine Homebuilding receives a commission for items purchased through links on this site, including Amazon Associates and other affiliate advertising programs.
X X This is a dialog window which overlays the main content of the page. The modal window is a 'site map' of the most critical areas of the site. Pressing the Escape (ESC) button will close the modal and bring you back to where you were on the page. SearchMain Menu
- How-To
- Design
- Tools & Materials
- Restoration
- Video
- Blogs
- Forum
- Project Guides
- Reader Projects
- Magazine
- Members
- FHB House
Podcasts
- FHB Podcast
- ProTalk
Webinars
- Upcoming and On-Demand
Podcasts
- FHB Podcast
- ProTalk
Webinars
- Upcoming and On-Demand
Popular Topics
- Kitchens
- Business
- Bedrooms
- Roofs
- Architecture and Design
- Green Building
- Decks
- Framing
- Safety
- Remodeling
- Bathrooms
- Windows
- Tilework
- Ceilings
- HVAC
Magazine
- Current Issue
- Past Issues
- Magazine Index
- Subscribe
- Online Archive
- Author Guidelines
All Access
- Member Home
- Start Free Trial
- Gift Membership
Online Learning
- Courses
- Project Guides
- Reader Projects
- Podcast
More
- FHB Ambassadors
- FHB House
- Customer Support
Account
- Log In
- Join
Newsletter
Get home building tips, offers, and expert advice in your inbox
GoSigning you up...
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply. See all newsletters See all newslettersFollow
- X
- YouTube
- Tiktok
Join All Access
Become a member and get instant access to thousands of videos, how-tos, tool reviews, and design features.
Start Your Free TrialSubscribe
Start your subscription today and save up to 71%
Subscribe Toggle Caption Previous NextMembers get unlimited site access.
To unlock this page, Start a Free Trial
Already a member? Log in
Tag » Why Are Outlets Upside Down
-
Why Are Outlets Upside Down In Commercial Buildings?
-
Why Are Electrical Outlets Sometimes "upside Down?"
-
Why Are Some Outlets Installed Upside Down?
-
Eli5: Why Is It Now Code To Install Outlets Upside Down? - Reddit
-
Why Are Outlets And Receptacles In Hospitals Upside Down?
-
How To Fix An Upside-Down Outlet - The Spruce
-
Why Are Outlets Upside Down? - Quora
-
Why Is My Electrical Outlet Upside Down? - Marty Ringham - LinkedIn
-
Why Are My Outlets Upside Down? - YouTube
-
Why Are All The Electrical Outlets In Hospitals Upside Down?
-
Why Are Some Electric Receptacle Outlets Upside Down (ground Slot ...
-
Les Perreaux On Twitter: "Why Are Quebec Power Outlets Upside ...
-
More Content - Facebook
-
Upside-down Outlets? - YouTube