Ground Fault Circuit Interrupters, GFCI Test Procedure How To Test A ...

InspectAPedia® - Search InspectApedia

InspectAPedia®

FREE Encyclopedia of Building & Environmental Construction, Diagnosis, Maintenance & Repair The accuracy & trustworthiness of every article or Q&A is researched by human experts. See WHO ARE WE?

Question? Just ask us!

Google InspectAPedia
  • HOME
  • SEARCH
  • AGE OF BUILDING +
    • AIR CONDITIONER & HEAT PUMP
    • BUILDING AGE- home
    • ARCHITECTURE - home
    • BULBS & CONNECTORS
    • CHIMNEYS & FIREPLACES
    • DOOR HARDWARE
    • DRYWALL, FIBERBOARD, PLASTER - home
    • ELECTRICAL RECEPTACLES
    • ELECTRICAL SYSTEMS
    • ELECTRICAL WIRING
    • FLOORING
    • FOUNDATION
    • FRAMING
    • HEATING EQUIPMENT
    • HEATER, BOILER, FURNACE
    • HISTORIC BUILDINGS
    • HVAC
    • INSULATION
    • KIT HOMES
    • LOG CABIN
    • NAILS SPIKES BOLTS - home
    • PLASTER
    • PLUMBING
    • PORCHES
    • ROOFING MATERIALS
    • SAW & AXE CUTS
    • SEPTIC SYSTEM
    • SIDING MATERIAL
    • WATER HEATER
    • WINDOWS & DOORS
  • AIR CONDITIONING +
    • A/C WON'T START
    • AGE of HVAC
    • AIR FILTERS - home
    • AIR HANDLER - home
    • BLOWER FAN
    • COMPRESSOR / CONDENSER - home
    • CONTROLS & SWITCHES
    • DIAGNOSTIC GUIDES
    • DUCT SYSTEM - home
    • EDUCATION COURSES
    • EVAPORATIVE COOLING
    • HARD START COMPRESSOR
    • HEAT PUMP
    • HEATING SYSTEM - home
    • MANUALS & PARTS - home
    • OPERATING COST
    • OPERATING TEMPERATURE
    • REFRIGERANT
    • REPAIR GUIDES- home
    • SPLIT SYSTEM - home
    • THERMOSTATS- home
    • VENTILATION - home
  • APPLIANCES +
    • ASBESTOS
    • CLOTHES DRYER
    • CLOTHES DRYER VENT
    • COFFEE MAKER
    • DISHWASHER
    • DOORBELL
    • EFFICIENCY RATINGS
    • ELECTRIC MOTOR
    • EXHAUST FAN
    • GARBAGE DISPOSER
    • GAS FIREPLACES LOGS
    • MICROWAVE
    • NOISE
    • OVEN DOOR
    • RANGE COOKTOP OVEN - home
    • REFRIGRATOR
    • THERMOCOUPLE
    • THERMOSTATS
    • TRASH COMPACTOR
    • VACUUM CLEANER
    • WASHING MACHINE
    • WASHING MACHINE vs SEPTIC
    • WATER HEATER
    • WINDOW / WALL AIR CONDITIONER
  • ARCHITECTURE +
    • AGE of a BUILDING
    • ARCHITECTURE ID - home
    • ARCHITECTURE STYLE & AGE
    • BUILD YOUR DREAM HOME
    • CHIMNEY
    • DEFINITIONS
    • DICTIONARY
    • HISTORIC & OLD BUILDINGS
    • HOUSE PARTS
    • KIT HOMES
    • MANUFACTURED HOME, DOUBLEWIDE
    • MOBILE HOME
    • MODULAR HOME
    • ROOF STYLE
    • ROOF DORMER
    • SIDING
    • WINDOWS
  • CODES +
    • ACCESS RESTRICTIONS
    • AFCI GFCI
    • CONCEALED SPACE FIRE
    • CRAWL SPACE VENTILATION
    • DANGEROUS CONDITIONS
    • ELECTRICAL
    • ELEVATOR & STAIR LIFT
    • FIRE RATING ROOF SURFACES
    • FRAMING TABLES, SPANS
    • GRABRAIL GRAB BAR
    • HANDRAIL
    • LIGHTING
    • MOBILE HOME
    • MOBILE OFFICE
    • RAILING - home
    • RETAINING WALL GUARDRAIL
    • ROOFING
    • SAFETY HAZARDS
    • STAIRS - home
    • SEPTIC DESIGN U.S.A.
    • SEPTIC & SEWAGE CODES
    • VENTILATION
  • CHIMNEY +
    • ABANDONED
    • BRACKET & GALLOWS
    • CRACK
    • DIRECT / SIDE WALL VENTS
    • DRAFT
    • FIRE CLEARANCES
    • FIREPLACES & HEARTHS - home
    • FLASHING
    • FLUE INSPECTION
    • FLUE SIZE
    • FLUE TILE DAMAGE
    • HEIGHT
    • INSPECTION
    • LEANING, MOVEMENT
    • MASONRY CHIMNEY - home
    • METAL CHIMNEYS & FLUES - home
    • RAIN CAP
    • RE-LINING
    • REPAIR
    • STAINS & LEAKS
    • UNLINED FLUES
    • WOOD STOVES - home
  • DAMAGE +
    • ANIMAL DAMAGE
    • DISASTER INSPECT REPAIR - home
    • EARTHQUAKE - home
    • FLOOD - home
    • FLOOD REPAIR PRIORITIES
    • HURRICANE DAMAGE
    • MOLD PREVENTION
    • ROOF DAMAGE, WIND
    • SALVAGE BUILDING CONTENTS
    • SINKHOLES, WARNING SIGNS
    • STORM-RESISTANT WINDOWS
    • STRUCTURAL INSPECTIONS
    • WILDFIRE DAMAGE
    • WIND DAMAGE
  • ELECTRIC +
    • AFCIs
    • ALUMINUM WIRING - home
    • AMPS VOLTS
    • BACK-WIRED DEVICES - home
    • BACKUP GENERATORS
    • BATHROOM FAN
    • BULBS - home
    • BX WIRING
    • CAPACITORS for MOTORS
    • CEILING LIGHT
    • CIRCUIT BREAKER FAILURE
    • CIRCUIT BREAKER / FUSE INSPECT
    • CIRCUIT ID, MAP & LABEL
    • CLEARANCES
    • COMPRESSOR MOTOR CAPACITOR
    • CONDUIT
    • COPPER-CLAD ALUMINUM WIRE
    • DEFINITIONS
    • DISTRIBUTION PANEL
    • DMM MULTIMETER
    • ELECTRICAL BOX
    • ELECTRICAL CODE BASICS
    • ELECTRICITY LOSS / FLICKERING LIGHTS
    • FEDERAL PACIFIC FPE- home
    • FLUORESCENT LIGHT
    • GENERATORS
    • GFCI
    • GROUND SYSTEM - home
    • KNOB & TUBE WIRING
    • LIGHTING, EXTERIOR - home
    • LIGHTING, INTERIOR - home
    • LOW VOLTAGEWIRING
    • METERS & BASES
    • MOTOR REPAIR - home
    • MOTOR WIRE SIZE
    • MULTI-WIRE CIRCUITS
    • NOISES, ELECTRICAL
    • OLD HOUSE ELECTRIC- home
    • OUTLET, WIRE - home
    • PANEL- home
    • RELAY SWITCHES
    • SAFETY
    • SERVICE ENTRY- home
    • SPLICE
    • THERMAL IMAGING
    • TURN BACK ON
    • ZINSCO SYLVANIA
  • ENERGY +
    • AIR CHANGE RATE
    • AIR LEAKS - home
    • AIR LEAKS RETURN DUCTS
    • AIR LEAKS SUPPLY DUCTS
    • BASEMENT HEAT LOSS
    • BIO-FUEL
    • BLOWER DOORS
    • DUCT SYSTEM
    • ENERGY AUDIT
    • ENERGY RETROFIT
    • ENERGY SAVINGS PRIORITY
    • ENERGY USE MONITOR
    • HEAT COST SAVINGS
    • HEAT LOSS INDICATORS
    • HIGH MASS TRADEOFFS
    • ROOF COLOR
    • R U & K VALUE
    • SEER RATING
    • SOLAR ENERGY
    • TIMERS
    • VENTILATION, HEAT COST
    • WATER HEATER TIMER
    • WIND ENERGY
    • WINDOW EFFICIENCY
  • ENVIRONMENT +
    • AIR POLLUTANTS
    • ALLERGENS +
    • ALLERGEN TESTS
    • ARSENIC HAZARDS
    • ASBESTOS HAZARDS
    • ASBESTOS IDENTIFICATION - home
    • ASBESTOS in THIS MATERIAL?
    • ASBESTOS LIST of PRODUCTS
    • ASBESTOS PHOTO GUIDE
    • BACKUP, SEPTIC-SEWAGE
    • BACTERIA, MOLD, POLLEN
    • BANNED ASBESTOS PRODUCTS
    • BEDBUGS
    • BIOLOGICAL POLLUTANTS
    • CEILING TILE ASBESTOS ID
    • CELL PHONE RADIATION
    • CHINESE DRYWALL
    • DISINFECTANTS, SANITIZERS, SEALANTS
    • ELECTROMAGNETIC FIELDS
    • FIBERGLASS HAZARDS
    • FIBERGLASS INSULATION MOLD
    • FIBERGLASS SHEDDING
    • FIBERGLASS CONTAMINANTS
    • FLOOR TILE ASBESTOS
    • FORMALDEHYDE HAZARDS
    • GAS DETECTION
    • HAZARD vs RISK
    • HOUSE DUST
    • INDOOR AIR QUALITY IAQ
    • MOLD CONTAMINATION
    • MOLD / ENVIRONMENT EXPERT
    • MORGELLONS SYNDROME
    • MYCOTOXIN EFFECTS
    • NOISE DIAGNOSIS
    • ODOR DIAGNOSIS
    • PESTICIDE EXPOSURE
    • POPCORN CEILING ASBESTOS
    • SEWAGE CONTAMINATION
  • EXTERIOR +
    • BRICK WALL WEEP HOLES
    • DECK & PORCH CONSTRUCT - home
    • DOORS, EXTERIOR
    • FIBER CEMENT SIDING - home
    • FLASHING on BUILDINGS - home
    • PAINT FAILURE
    • LIGHTNING PROTECTION
    • PAINT FAILURE - home
    • RAMPS, ACCESS - home
    • SHEATHING, FIBERBOARD
    • SLIP TRIP & FALL HAZARDS
    • STAIR CONSTRUCTION - home
    • STAIR DIMENSIONS
    • STUCCO WALL METHODS
    • WINDOWS & DOORS, AGE, TYPES
  • HEAT +
    • AGE of A/C & HEAT PUMPS
    • AGE of HEATER, BOILER, FURNACE
    • AIR FILTERS f- home
    • AIR HANDLER / BLOWER UNIT - home
    • AQUASTAT CONTROL - home
    • BACKDRAFTING
    • BACKUP HEAT for HEAT PUMPS
    • BANGING HEAT SYSTEM NOISES
    • BANGING HEAT ZONE VALVES
    • BANGING PIPES RADIATORS
    • BUZZING NOISE
    • BASEBOARD HEAT REPAIR - home
    • BLOWER FAN
    • BOILERS - home
    • CAD CELL RELAY
    • CHECK VALVES
    • CIRCULATOR PUMPS- home
    • CLEARANCE DISTANCES
    • COMBUSTION AIR
    • CONDENSING BOILERS/FURNACES
    • CONTROLS & SWITCHES
    • CONVECTOR HEATERS
    • DAMPERS & DRAFT REGULATORS
    • DATA TAGS
    • DIAGNOSE & FIX A/C / HEAT PUMP
    • DIAGNOSE & FIX BOILER - home
    • DIAGNOSE & FIX FURNACE - home
    • DIRECT VENT / SIDE WALL VENT
    • DRAFT REGULATORS / HOODS, GAS
    • DRAFT MEASUREMENT
    • DRAFT REGULATOR
    • DUCT SYSTEM - home
    • ELECTRIC HEAT - home
    • EVAPORATIVE COOLING SYSTEM
    • EXPANSION TANK, BOILER - home
    • FAN, AIR HANDLER BLOWER - home
    • FAN LIMIT SWITCH - home
    • FILTERS, AIR
    • FILTERS, OIL
    • FIRE SAFETY CONTROLS
    • FIREPLACES & HEARTHS - home
    • FLUE SIZE
    • FURNACE CONTROLS
    • FURNACES, HEATING - home
    • GAS BURNER FLAME & NOISE
    • GAS BURNER PILOT LIGHT
    • GEOTHERMAL HEAT
    • HEAT PUMP REPAIR - home
    • HEAT LOSS DIAGNOSIS-BOILERS
    • HEAT LOSS DIAGNOSIS-FURNACES
    • HEAT WON'T TURN OFF
    • HEAT WON'T TURN ON
    • HEATING COST SAVINGS
    • HEATING OIL- home
    • HEATING SYSTEM NOISE
    • HUMMING NOISE
    • LIFE EXPECTANCY A/C / HEAT PUMP
    • LIFE EXPECTANCY FAN / WALL CONVECTOR
    • LIFE EXPECTANCY FURNACE
    • LOW VOLTAGE WIRING
    • MANUALS
    • MINI SPLIT A/C & HEAT PUMPS
    • MOBILE HOME HEAT
    • NO HEAT - BOILER
    • NO HEAT - FURNACE
    • OIL STORAGE TANKS
    • OPERATING TEMPERATURES
    • PORTABLE ELECTRIC HEATER
    • RADIANT HEAT
    • STEAM HEAT
    • THERMOSTATS - home
    • THERMOSTAT WIRING
    • ZONE VALVES
  • INSPECTION +
    • ADVANCED METHODS
    • CARPENTER ANTS
    • CARPENTER BEES
    • DISASTER INSPECTION- home
    • DUST SAMPLING
    • FEAR-O-METER: Dan's 3 D's SET REPAIR PRIORITIES
    • FIBER & HAIR IDENTIFICATION
    • FIBERGLASS PARTICLE
    • FIRE OFF-GASSING
    • FORENSIC INVESTIGATION
    • GAS TEST PROCEDURES
    • HISTORIC & OLD BUILDINGS
    • HOUSE DUST ANALYSIS
    • INSECT INFESTATION - home
    • LIGHT, GUIDE to FORENSIC USE
    • LIGHT, UV BLACK LIGHT USES
    • MICROSCOPY
    • STRUCTURAL DAMAGE PROBING
    • TERMITE DAMAGE
    • THERMAL EXPANSION
  • INDOOR AIR +
    • AIRBORNE MOLD LEVEL
    • AIRBORNE PARTICLE ANALYSIS
    • ALLERGEN TESTS
    • ANIMAL ALLERGENS DANDER
    • CARBON DIOXIDE
    • CARBON MONOXIDE
    • CARPETING
    • CAT DANDER
    • COMBUSTION GASES
    • DUST SAMPLING
    • EMERGENCY RESPONSE, IAQ, GAS, MOLD
    • FIBERGLASS - home
    • HUMIDITY
    • IAQ & HOUSE TIGHTNESS
    • INDOOR AIR HAZARDS
    • ODORS GASES SMELLS- home
    • VENTILATION
  • INSULATION +
    • ATTIC
    • BASEMENT
    • FIBERGLASS
    • FRAMING DETAILS
    • HOT ROOF PROBLEMS
    • INSULATION AIR & HEAT LEAKS
    • INSULATION CHOICES
    • INSULATION FACT SHEET- DOE
    • INSULATION GREENHOUSE
    • INSULATION ID
    • INSULATION LOCATION
    • INSULATION MOLD
    • INSULATION R-VALUES
    • POLYSTYRENE FOAM
    • RIGID FOAM
    • UFFI UREA FORMALDEHYDE FOAM
  • INTERIOR +
    • ASBESTOS in DRYWALL
    • BATH & KITCHEN DESIGN - home
    • CABINETS & COUNTERTOPS - home
    • CARPETING - home
    • CARPET STAIN ID
    • CEILING STAIN DIAGNOSIS
    • CERAMIC TILE FLOOR, WALL
    • CONDENSATION
    • COUNTERTOPS
    • DRYWALL FIBERBOARD PLASTER- home
    • EFFLORESCENCE WHITE DEPOSIT
    • FIBERBOARD- home
    • FIREPLACES & HEARTHS
    • FLOOR, CONCRETE SLAB
    • FLOOR TYPES & DEFECTS - home
    • INTERIOR FINISHES
    • KITCHEN DESIGN
    • MOISTURE CONTROL
    • PAINT FAILURE - home
    • PLASTER METHODS
    • RESILIENT SHEET FLOORING - home
    • SHEATHING, FIBERBOARD
    • SHEET FLOORING ID
    • SLIP TRIP & FALL
    • STAIR CONSTRUCTION
    • STAIN DIAGNOSIS
    • STUCCO WALL METHODS
    • THERMAL TRACKING
    • TILED SURFACES
    • TRIM, INTERIOR
    • WALL FINISHES
    • WOOD STOVE OPERATION - home
    • WOOD FLOOR DAMAGE
  • MOBILE HOME +
    • BUYERS ADVICE
    • CODES & MANUALS
    • COMBUSTION AIR SAFETY
    • CONNECTIONS, MULTI-WIDE
    • COOLING SYSTEM
    • CRAWL SPACES
    • CROSSOVER CONNECTORS
    • DATA TAGS & LABELS
    • DEMOLISH REMOVE MOVE
    • ELECTRICAL POWER LOST
    • ELECTRICAL SYSTEM
    • EMERGENCY EGRESS WINDOWS
    • ENERGY ZONES
    • EXTERIOR DEFECTS
    • FLICKERING LIGHTS
    • FOUNDATIONS
    • GFCI DIAGNOSIS
    • HEALTH DEPARTMENT HELP
    • HEATING SYSTEM
    • INSPECTIONS
    • INSULATION & VENTILATION
    • INTERIOR DEFECTS
    • LEAKS
    • MODULAR CONSTRUCTION
    • MOLD CONTAMINATION
    • PIERS
    • PLUMBING
    • ROOF
    • SAFETY
    • SKIRTING
    • STABILIZING & TIE DOWNS
    • STRUCTURE
    • TEMPORARY OFFICE TRAILER
    • WALL DEFECTS
    • WATER HEATERS
    • WIND RATINGS
    • WINTERIZE
  • MOLD +
    • ACTION GUIDE
    • AIRBORNE MOLD COUNT - home
    • AIRBORNE PARTICLE LEVEL- home
    • ASPERGILLOSIS
    • ATTIC MOISTURE or MOLD
    • BLACK MOLD, HARMLESS
    • BLEACHING MOLD
    • BOOK / DOCUMENT MOLD
    • CABINET MOLD
    • CACTUS FUNGI / MOLD
    • CAR MOLD CONTAMINATION
    • CARPET MOLD / ODOR TESTS
    • CAR MOLD CONTAMINATION
    • CEILING STAIN DIAGNOSIS
    • DIRT FLOOR MOLD
    • DRYWALL MOLD
    • DUST / MOLD SAMPLING
    • EFFLORESCENCE & WHITE DEPOSITS
    • EMERGENCY RESPONSE
    • FEAR of MOLD - MYCOPHOBIA
    • FIBERBOARD SHEATHING MOLD
    • FIBERGLASS INSULATION MOLD
    • FIND MOLD, ESSENTIAL STEPS
    • FOXING STAINS
    • HARD TO SEE MOLD, SPOTTING
    • HIDDEN MOLD
    • HUMIDITY CONTROL & TARGETS
    • LIGHT, USE TO FIND MOLD
    • MERULIPORIA FUNGUS
    • MILDEW
    • MOBILE HOME MOLD
    • MODULAR HOME MOLD
    • MOLD A COMPLETE GUIDE - home
    • MOLD SAFETY ADVICE for TENANTS
    • MOLD CLEANUP
    • MOLD AGE
    • MOLD APPEARANCE
    • MOLD CLEARANCE INSPECTION
    • MOLD COUNT NUMBERS
    • MOLD CULTURE SAMPLING
    • MOLD DETECTION
    • MOLD DOCTOR
    • MOLD ENVIRONMENTAL EXPERTS
    • MOLD EXPOSURE STANDARDS
    • MOLD FREQUENCY
    • MOLD INVESTIGATION PROCEDURE
    • MOLD ODORS, MUSTY SMELLS
    • MOLD PREVENTION - home
    • MOLD RELATED ILLNESS
    • MOLD SANITIZER, SPRAY, BIOCIDE
    • MOLD TEST PROCEDURES
    • MVOCs & MOLDY MUSTY ODORS
    • MYCOTOXIN EFFECTS
    • OZONE TREATMENT WARNING
  • NOISE +
    • BANGING BOOMING NOISES - home
    • ELECTRICAL SYSTEM NOISE
    • FAN NOISES
    • HEATING SYSTEM NOISE
    • HVAC SYSTEM NOISE
    • NOISE CONTROL for ROOFS
    • PLUMBING SYSTEM NOISE - home
    • RELAY SWITCH NOISE
    • ROOF IMPACT NOISE
    • ROOF NOISE TRANSMISSION - home
    • SOUND CONTROL
    • TEMPERATURE CHANGE & ROOF NOISE
    • WATER HAMMER NOISE
  • ODOR +
    • AIR CONDITIONING
    • ANIMAL or URINE
    • CAR ODORS, ANIMALS
    • FLOOR DRAIN / TRAP
    • METHANE & SEWER GAS
    • MOLD ODORS
    • MVOCs MOLDY MUSTY
    • ODOR CONTROL for SEPTIC
    • ODORS FROM HEATING SYSTEMS
    • ODORS, PLUMBING SYSTEM
    • ODORS, SEPTIC or SEWER
    • ODOR SENSITIVITIY
    • OZONE MOLD / ODOR TREATMENT
    • PLUMBING SYSTEM - home
    • SMELL PATCH FIND ODOR SOURCE
    • URINE ODOR SOURCE
    • WATER ODOR CURE
  • PLUMBING +
    • AIR DISCHARGE at FAUCETS
    • CHECK VALVES
    • CLEARANCE DISTANCES
    • CLOGGED DRAIN REPAIR
    • COMPOSTING TOILETS
    • DISPOSABLE WET WIPE CLOGS
    • DRAIN CLEANOUTS
    • FLOOR DRAIN / TRAP ODORS
    • GAS TANKS & PIPING
    • OIL TANKS & PIPING
    • PLUMBING TRAPS
    • PLUMBING VENTS - home
    • SEPTIC SYSTEMS
    • SEWAGE PUMPS - home
    • TANKLESS COIL HOT WATER
    • TOILETS - home
    • WATER HEATERS, ELECTRIC - home
    • WATER PIPE CLOG
    • WATER PRESSURE DIAGNOSE
    • WATER PRESSURE IMPROVE
    • WATER PRESSURE LOSS- home
    • WATER PUMPS & WELLS
    • WATER SHUTOFF VALVE
    • WATER SOFTENERS - home
    • WATER PIPING - home
    • WATER TANK - home
    • WINTERIZE A BUILDING
  • ROOF +
    • AGE
    • ASBESTOS & FIBER CEMENT - home
    • ASPHALT SHINGLES - home
    • CLAY TILE - home
    • CLEANING
    • COLOR
    • CONCRETE
    • CONTRACTOR, CHOOSE
    • CORRUGATED
    • DEBRIS STAINING
    • DISPUTE RESOLUTION
    • EPDM, RUBBER, PVC
    • EXTRACTIVE BLEEDING SHINGLES
    • FELT UNDERLAYMENT - home
    • FIBER CEMENT ROOFING - home
    • FIBERBOARD & FIBER-WOOD
    • FIRE RATINGS
    • FLASHING on BUILDINGS - home
    • FLAT ROOF LEAKS
    • HAIL DAMAGE
    • ICE DAM
    • INSPECTION
    • LEAD ROOFING & FLASHING
    • LEAK REPAIR - home
    • LOW SLOPE - home
    • MATERIALS, AGE, TYPES
    • MEMBRANE & SINGLE PLY
    • METAL- home
    • PLASTIC ROOFING TYPES
    • PVC, EPDM, RUBBER MEMBRANE
    • ROLL ROOFING, ASPHALT & SBS
    • RUBBER SHINGLES SLATES
    • SBS ROOFING ROLL & BUR ROOFS
    • SEALANTS & MASTICS
    • SHINGLE STORAGE
    • SLATE - home
    • SLOPE CALCULATIONS
    • STAINS - home
    • STANDARDS
    • STONE ROOF
    • THATCH ROOF
    • TILE, CLAY - home
    • TILES, CONCRETE
    • VENTILATION - home
    • WALKABLE
    • WARRANTIES
    • WHITE STAINS - home
    • WIND DAMAGE
    • WIND NOISES
    • WIND DAMAGE RESISTANT
    • WOOD SHAKE & SHINGLE - home
    • WORKMANSHIP & DAMAGE
  • SEPTIC +
    • AEROBIC ATUs - home
    • AGE of SEPTIC SYSTEM
    • BACKUP PREVENTION
    • BIOMAT FORMATION & SEPTIC LIFE
    • BOD WASTEWATER TEST
    • CAMERAS, SEWER / SEPTIC
    • CARE - home
    • CESSPOOLS
    • CHAMBER SEPTIC SYSTEMS
    • CLEARANCE DISTANCES
    • CLOGGED DRAIN REPAIR
    • CLOGGED DRAIN FIELD
    • CODES - home
    • COMMERCIAL SEPTIC
    • COMPONENT LOCATIONS - home
    • D-BOX INSTALL REPAIR
    • DESIGN ALTERNATIVES - home
    • DESIGN BASICS - home
    • DESIGN PREVENT FLOOD DAMAGE
    • DIFFICULT SEPTIC SITE
    • DISPERSAL METHODS
    • DISPOSAL vs TREATMENT
    • DRAINFIELD TEST - home
    • DRIVING OVER SEPTIC
    • DRYWELL
    • EFFLUENT DISTRIBUTION
    • EFFLUENT RETENTION TIME
    • FAILURE SIGNS
    • FILTERS
    • FLOODED SYSTEM REPAIR
    • FREEZE PROTECTION
    • FREEZE-UP SOLUTIONS
    • FROZEN AEROBIC SEPTIC
    • GARBAGE DISPOSAL vs SEPTICS
    • GRAVELLESS SEPTIC
    • GREYWATER SYSTEMS
    • HOOT AEROBIC SEPTIC
    • HOME BUYERS GUIDE
    • HOME SELLERS GUIDE
    • HOW SEPTIC SYSTEMS WORK
    • INSPECT & TEST - home
    • INSPECT & TEST LAWS
    • LAUNDROMAT WASTEWATER
    • LIFE EXPECTANCY
    • LOADING & DYE TEST - home
    • LOW COST SYSTEMS
    • MAINTENANCE - home
    • MEDIA FILTER SYSTEMS - home
    • ODOR CONTROL
    • ODORS, SEWER GAS
    • PLANTS OVER SEPTIC SYSTEMS
    • PUMPING the SEPTIC TANK
    • PUMPS
    • REPAIR - home
    • SAFETY
    • SANDY SOIL SYSTEMS
    • SEEPAGE PITS
    • SEWAGE BACKUP
    • SEWAGE CONTAMINANTS
    • SEWAGE TREATMENT PLANTS
    • SEWER CONNECTION? - home
    • TANKS - home
    • TANK CLEANING
    • TANK COVERS
    • TANK DEPTH
    • TANK, HOW TO FIND
    • TANK PUMPING
    • TANK PUMPING SCHEDULE
    • TANK TEES
  • STRUCTURE +
    • ADOBE CONSTRUCTION
    • BASEMENT WATERPROOFING
    • BLOCK FOUNDATION / WALLS - home
    • BRICK FOUNDATIONS & WALLS - home
    • BUILDING DAMAGE REPAIR
    • BULGED vs. LEANING FOUNDATIONS
    • CARPENTER ANTS
    • CHIMNEY REPAIR - home
    • CLAY HOLLOW TILE
    • CLEARANCE DISTANCES - topic home
    • COLUMNS & POSTS, DEFECTS
    • CONCRETE FOUNDATION, WALL, SLAB
    • CONTROL JOINT CRACKS
    • CRAWL SPACES
    • DAMAGE ASSESSMENT
    • DECK & PORCH - home
    • EARTHQUAKE, FLOOD, DISASTER
    • FIBERBOARD SHEATHING - home
    • FIRE ESCAPES & STAIRS
    • FIRE STOPPING
    • FOUNDATION TYPES
    • FOUNDATION CRACKS & DAMAGE- home
    • FOUNDATION REPAIR - home
    • FRAMING AGE, SIZE, SPACING, TYPES
    • FRAMING CONNECTORS
    • FRAMING DAMAGE REPAIR - home
    • FRAMING FASTENERS
    • FRAMING SQUARE - home
    • FRAMING TABLES, SPANS
    • HOUSEWRAP
    • INSECT DAMAGE - home
    • LOG HOME REPAIR
    • MOBILE HOMES
    • MODULAR CONSTRUCTION
    • MOISTURE CONTROL
    • PANELIZED CONSTRUCTION
    • PORCH CONSTRUCTION
    • ROOF BEND SAG COLLAPSE
    • ROOF FRAMING TIES & BEAMS
    • ROOF TRUSS UPLIFT
    • ROT TYPES
    • SHIPPING CONTAINER HOUSING
    • SINKHOLES / SUBSIDENCES
    • STAIRS, RAILINGS, LANDINGS, RAMPS - home
    • STRESS SKIN / SIPS
    • STRUCTURAL DAMAGE PROBING
    • TERMITE INSPECTION & DAMAGE
    • TIMBER FRAMING, ROT
    • TRUSSES, FLOOR & ROOF
    • TRUSS UPLIFT, ROOF
    • WATER ENTRY, LEAKS
    • WOOD STRUCTURE ASSESSMENT
  • VENTILATE +
    • ATTIC VENTILATION
    • BALANCED VENTILATION
    • BATHROOM VENT CODES - home
    • BATHROOM VENT DUCT ROUTING
    • KITCHEN VENT DESIGN
    • HIP ROOF VENTILATION
    • HOT ROOF PROBLEMS
    • ICE DAM PREVENTION
    • ROOF ICE DAM LEAKS
    • ROOF VENTILATION CODE- home
    • SKYLIGHT VENTILATION
    • SOFFIT VENTILATION
  • WATER +
    • AIR VOLUME CONTROLS
    • ARTESIAN WELLS, SPOOLS
    • CHECK VALVES
    • CHEMICAL CONTAMINANTS
    • CISTERNS
    • FOOT VALVES
    • GREYWATER SYSTEMS - home
    • NO WATER PRESSURE
    • ODORS
    • PUMP PRESSURE CONTROL
    • PUMPS
    • SPRINGS
    • SWIMMING WATER
    • WATER CONSERVATION- home
    • WATER CONTAMINATION - home
    • WATER FILTERS
    • WATER METERS
    • WATER ODORS
    • WATER POLLUTANTS
    • WATER PRESSURE BOOSTER
    • WATER PRESSURE LOSS - home
    • WATER PRESSURE REDUCER / REGULATOR
    • WATER PUMP PRESSURE CONTROL
    • WATER PUMP PRIMING
    • WATER PUMP REPAIR - home
    • WATER TANK REPAIR - home
    • WATER TESTS - home
    • WATER TREATMENT - home
    • WELLS CISTERNS & SPRINGS - home
  • CONSULT
  • ESTIMATE
  • CONTACT
Siemens GFCI circuit breaker at InspectApedia.comGround Fault Circuit Interrupters, GFCI Test Procedure How to Test a GFCI
  • POST a QUESTION or COMMENT about ground fault circuit interrupters

Ground Fault Circuit Interrupters, GFCI testing:

Here we cite expert sources' description of the proper way to test a ground fault circuit interruptor GFCI for proper and safe operation.

We include additional notes on situations in which proper testing is impossible even though the device might actually work if a current leak to ground or neutral occurs on the circuit.

This article series GFCIs and AFCIs as well as safe GFCI & AFCI installation, wiring, testing, and inspection.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

GFCI Testing Instructions

GFCI wall receptacle or A GFCI or Ground-Fault Circuit Interrupter is a safety device intended to prevent electrical shock by detecting an improper flow of electrical current and shutting the electrical circuit off very quickly - in milliseconds.

The GFCI is designed to protect people from severe or fatal electric shocks by quickly detecting a small flow of electrical current between the electrical circuit (wires, switch, electrical receptacle or something plugged-in to the receptacle) and "ground" or the earth.

A GFCI also can protect against some electrical fires by detecting arcing and other faults to ground but a GFCI cannot detect hazardous across-the-line arcing faults that can cause fires.

[Click to enlarge any image]

The photo also shows an independent GFCI test tool plugged into the lower receptacle openings.

On the GFCI tester the round black button on the top of the devicve is an independent test button that attempts to simulate a short to ground or neutral. If the device tester trips the GFCI the RED RESET button will pop out as above.

GFCI Test Procedure for Receptacles: Using the Receptacle Built-In Test & Reset Buttons

Red and black test & reset buttons on a GFCI receptacle (C) Daniel Friedman at InspectApedia.com

On many GFCI wall receptacles the TEST button is red and the RESET button is black (photo above), but as you can see in our earlier photo above and in a closer view below, on other models there is no color code.

You'll notice in our photo below that one button is emossed with the word TEST (our red arrow) and the other with the word RESET (our black arrow).

In these photos the GFCI TEST button on the wall receptacle itself checks the wiring connections at the GFCI receptacle.

The RESET button on the electrical GFCI receptacle will pop out if the device is tripped off. Pushing the RESET button all the way in should re-set the device and restore electrical power.

Identify the TEST & RESET buttons on a GFCI wall receptacle (C) Daniel Friedman at InspectApedia.com

The following GFCI test details are adapted from advice from Eaton CH cited just below.

(a) Turn the power ON at the service panel. Press the RESET button fully. Plug a lamp or radio into the GFCI (and leave it plugged-in) to verify that the power is ON. If there is no power, go to Troubleshooting. (b) Press the TEST button in order to trip the device.

This should stop the flow of electricity, making the radio or lamp shut OFF and the yellow Correct Wiring/Trip Indicator come on. To restore power, press the RESET button. (c) Test Downstream receptacles: If you installed your GFCI using step 7B, [that stepincludes wiring to protect downstream or surrounding receptacles - Ed.] now plug a lamp or radio into surrounding receptacles to see which one(s), in addition to the GFCI, lost power when you press the TEST button.

Do not plug life saving devices into any receptacles that lost power.

Place a “GFCI Protected” sticker on every receptacle that lost power. (d) Press the TEST button (then RESET button) every month to assure proper operation. (e) Note that this Eaton GFCI is shipped in the Tripped state and cannot be Reset until it is wired correctly and powered from it’s Line terminals. (f) Note that the RESET button will pop-out. If the power goes OFF and the correct wiring/trip indicator stays on, you have installed the GFCI receptacle correctly. (g) LINE/LOAD reversal will be indicated by the reset button not staying in after being pressed.

Such LINE/LOAD reversal will also be indicated by failure of the Correct Wiring/Trip Indicator to be on while the GFCI is tripped.

- source: Eaton, INSTALLING & TESTING a GFCI RECEPTCLE [PDF], Eaton, Website: www.eaton.com or www.cooperwiringdevices.com retrieved 2018/07.27,original source: http://www.cooperindustries.com/content/dam/public/wiringdevices/products/documents/instruction_sheets/EIS-0018-E.pdf Excerpt: Watch out: If you miswire the GFCI, it may not prevent personal injury or death due to a ground fault (electric shock). Upon initial installation, if you mistakenly connect the LINE wires to the LOAD terminals, this Eaton GFCI will not be able to be reset, and will therefore not provide power to it’s receptacle face or load terminals.

Watch out: the integral test buttons on a GFCI device installed on an electrical circuit that has no ground, such as on a knob and tube circuit will generally not work because the device expects the GFCI device to be connected to an electrical ground (used to simulate a current leak.

However the device might still work properly if there is an actual current leak between the GFCI device or receptacle, or something plugged into-it, and ground or neutral.

More about this test limitation including a discussion of testing GFCI devices installed on knob-and-tube electrical circuits or un-grounded circuits is found

at AFCI GFCI WIRING, TESTING & SAFETY .

GFCI Receptacle Test Procedure using a Plug-In Receptacle Tester

Using a receptacle tester to test a GFCI operation (C) Daniel Friedman at InspectApedia.comIn our photo above, you can see the built-in red TEST and black RESET buttons on this GFCI wall receptacle, but we're going to use an independent test device, the plug-in GFCI receptacle tester that wev'e inserted into the lower openings of the receptacle.

While the wall receptacle's built-in test and reset buttons are useful, this test is less complete than the test made using an external, plug-in test device.

Our photo shows a GFCI tester: the red light is off and the two yellow lights are on, indicating that this receptacle is wired properly.

When we push the black "test" button on our test device the GFCI receptacle should trip OFF.

GFCI Receptacle Test Procedure Details using a plug-in tester

  • Correct GFCI wiring: Plug this receptacle tester into a ground fault circuit interrupter GFCI outlet (which you should have or want in lots of locations in your home such as baths, kitchen, garage, basement, outdoors). Just by plugging it in the device without pushing its test button (under my finger in the photo) tests to see not only if the GFCI is wired properly.
  • Nuisance tripping: Just plugging in the device will also detect if the GFCI is going to trip unnecessarily - nuisance tripping - because the tester includes a built-in but very tiny current leak to ground - less than 14 mA, a current level below that at which the GFCI should trip.
  • Ground fault detection: now push the test button Then if you push the black test button the tester will put a 14 mA current leak on to the GFCI to see that the GFCI will trip if a ground fault occurs. That is, the test checks to see if the GFCI is doing its job. ( Watch out: you can perform the first group of tests above but you cann NOT heck for the presence of a proper electrical ground nor test a GFCI with this device IF the GFCI outlet is connected to a two-wire circuit that lacks a ground path. The GFCI might still trip when it should to protect someone from an electric shock but you can't easily test for that condition.

See ELECTRICAL TOOLS BASIC for details of the meaning of the all combinations of indicator lights on plug-in type wall receptacle testers including GFCI testers in our dicsussion titled " Electrical receptacle tester and GFCI tester (outlet tester)".

How To Re-Set a Tripped Receptacle Type GFCI

Un-Plug any tools or devices that are connected to the receptacle circuit whose GFCI tripped off.

Press and hold the RESET button on the device.

That should re-set the GFCI.

This procedure will usually apply as well to portable GFCI devices such as those discussed

at GFCI DEVICE SELECTION & WIRING

Watch out: If the GFCI will NOT re-set when you press the RESET button it's likely that there is an unsafe condition on the circuit or circuit wiring itself.

In that case leave the circuit switched OFF at the electrical panel and ask for help from a licensed electrician. She will trace the circuit to find the problem such as a short to ground or a short to neutral in circuit wiring.

An example that we encountered was a short to neutral when the screw tightening a clamp that connected flexible metal cable conduit to a metal electrical box was screwed-in too tightly and where the normal plastic bushing inside the fitting had been omitted.

The sharp metal edge of the BX armored cable cut into and shorted the hot and neutral wires together.

More help is at CIRCUIT BREAKER RESET STEPS

GFCI Test Procedure for GFCI Circuit Breakers

GFCI circuit breakers in an electrical panel (C) Daniel Friedman at InspectApedia.com

As our illustration shows, a GFCI circuit breaker also has a "TEST" button that is depressed to test the device.

How to Re-Set a Circuit-Breaker Type GFCI

Instead of a reset button such as is found on a GFCI receptacle, on the GFCI circuit breaker the test function will trip the breaker toggle.

You will need to re-set the circuit breaker by

  • first moving the toggle first to OFF or on some models past OFF,
  • then move it to the ON position.

More help is at CIRCUIT BREAKER RESET STEPS

GFCI Test Procedures, Standards, Documents

  • Eaton, INSTALLING & TESTING a GFCI RECEPTCLE [PDF], Eaton, Website: www.eaton.com or www.cooperwiringdevices.com retrieved 2018/07.27,original source: http://www.cooperindustries.com/content/dam/public/wiringdevices/products/documents/instruction_sheets/EIS-0018-E.pdf
  • Hubbell, INSTALLING & TESTING a GFCI RECEPTACLE [PDF] , Hubbel Corporation, 40 Waterview Dr., Shelton CT 06484 USA, Website: retrieved 2018/07/27, original source: http://www.arrl.org/files/file/Technology/GroundingAndBonding/Installing%20and%20Testing%20a%20GFCI%20Receptacle.pdf
  • Craftsman GFCI RECEPTACLE TESTER INSTRUCTIONS [PDF] Craftsman, Sears brands Management, Hoffman Estates IL 60179 USA, Tel: 800-326-1006 Website: www.craftsman.com,
  • Gardner Bender GFCI RECEPTACLE TESTER INSTRUCTIONS [PDF] Gardner Bender Milwaukee WI 53201, Web: www.gardnerbender.com (made in China)
  • Ideal, GFCI RECEPTACLE TESTER INSTRUCTIONS [PDF] Ideal Industries
  • Klein GFCI RECEPTACLE TESTER INSTRUCTIONS [PDF] Klein Tools, Inc., 450 Bond St., Lincolnshire IL 60089 USA Tel: 800-553-4676, web: www.kleintools.com Email: [email protected]
  • Larson Electronics, Tel: 1-877-432-0861 / International: 1-903-498-3363 Email: [email protected], Website: larsonelectronics.com Larson provides GFCI protected linecords and other electrical equipment.
  • Legrand, INSTALLING and TESTING a GFCI RECEPTACLE [PDF] Pass & Semour Legrand, PO Box 4822, Syracuse NY 13221 USA, Tel: 800-223-4185, Website: www.legrand.us, retrieved 2018/07/27, original source: Excerpt: This is a Self-Test GFCI Receptacle with SafeLock Protection™; it conducts an automatic test every three seconds, ensuring it’s always ready to protect. If the device fails the test, the indicator light flashes to signal that the GFCI should be replaced. It also has our proven SafeLock Protection feature: if critical components are damaged and protection is lost, power to this receptacle, and any downstream receptacles, will be disconnected.
  • Leviton, GFCI INSTALLATION & TEST PROCEDURES [PDF], retrieved 2018/07/27, original source: https://www.leviton.com/en/docs/guidelight.pdf
  • Novatech GFCI RECEPTACLE TESTER INSTRUCTIONS [PDF] Novatech, Internatibal, Cole-Parmer & Davis Instruments, Tel: (866) 433-6682 Email: [email protected] Web: www.novatech-usa.com
  • Siemens GFCI CIRCUIT BREAKER DATA SHEET & WIRING DIAGRAMS [PDF] retrieved 2018/09/07, original source: siemens.com/gfci
  • Siemens CIRCUIT BREAKER & GROUND FAULT CIRCUIT INTERRUPTER Specifications Sheet [PDF] retrieved 2018/09/07, original source: https://gfiwarehouse.com/~gfiwareh/siemensdatasheet.pdf
  • Southwire GFCI RECEPTACLE TESTER INSTRUCTIONS [PDF] (2016) Southwire Tools, One Southwire Dr., Carrolton GA 30119 USA (made in China)
  • Sperry GFCI RECEPTACLE TESTER INSTRUCTIONS [PDF] Sperry Instruents,
  • GFCI WORKPLACE TEST REQUIREMENTS OSHA U.S. OSHA, - retrieved 2018/07.27, original source: www.osha.gov/laws-regs/standardinterpretations/1992-02-10
  • U.S. CPSC, What is a GFCI, [PDF] U.S. Consumer Product Safety Commission, retrieved 2018/07.27, original source: https://www.cpsc.gov/s3fs-public/099_0.pdf
  • Also see AFCI GFCI WIRING, TESTING & SAFETY

Reader Comments &

On 2021-07-29 by inspectapedia.com.moderator (mod)

@Mack, The typical plug-in GFCI receptacle tester works by making an internal short to ground - that should work on a conventional receptacle that has GFCI or ground-fault circuit interrupter) protection anywhere upstream from the test point. That protection can be a GFCI receptacle or it can be a GFCI circuit breaker. Really? It's interesting (perhaps significant) that the test of GFCI circuit breakers using these tools is NOT mentioned explicitly in any of the receptacle-type GFCI receptacle tester instructions that we provide above on this page - from 7 different sources. Here are two examples: GFCI TESTER INSTRUCTIONS, SOUTHWIRE [PDF] https://inspectapedia.com/electric/GFCI-Receptacle-Tester-Instructions-Southwiretools.pdf GFCU TESTER INSTRUCTIONS, KLEIN TOOLS [PDF] https://inspectapedia.com/electric/GFCI-Receptacle-Tester-Instructions-Kleintools.com.pdf

On 2021-07-29 by Mack

Can a gfci breaker be tested by using a plug tester with the test button

On 2020-03-10 by (mod)

Alan Thanks for the interesting points - ones that we'll be sure to keep with the article. Indeed there is probably no GFCI tester on the market that is designed for in-field use that considers trip time. The good news is that the most-essential, most-common GFCI faults - the ones most-likely to cause a failure and perhaps injury or worse - are not trip times but rather no-trips - a mis-wired GFCI that simply won't trip in response to a current leak to neutral or to ground. It's also worth noting that the internal test exercised by pushing the test button on a GFCI depends on a proper local ground connection that may be absent entirely in some GFCI installations (such as on 2-wire circuits) - those GFCI's cannot be tested by normal means, even if the GFCI would trip in response to a short to neutral or to some other ground.

On 2020-03-10 by Alan

Before I worked at the mine I worked for an Electrical OEM where we did breaker and ground fault testing.

Anyone who had done breaker testing with current knows the expensive equipment that it takes to do this job. Does not really matter if it is primary or secondary injection. I was working at a open pit mine in NW when this first reared its ugly head. We were instructed to put a gfci in every location there was water/liquid.

So a coffee pot on a cabinet without a sink qualified. We installed gcfi's by the 100's. Then the inspector came back and said he wanted a testing record for all of the gfci's.

At the time there was no REAL gfci testing equipment out there. I objected to the concept of self testing. We tested grounding in the process building records for all equipment. Required a meter and checking the continuity for all the equipment. ( Lots of work to do this)

I started asking to what standard did the IMSHA inspector wanted these to be tested. He said whatever the manufacturer published.

The self testing issue sprung to the top of the list. Our management and our inspectors did not know there are different levels for gfci's. They were thinking that they were all the same. Until I pointed out gfcis for equipment protection. Which if installed on a personnel circuit could be bad news. They were unaware of those.

I found this on and IEEE page.

"A GFCI de-energizes the circuit when the leakage current level reaches 5 ± 1 mA in 1/40 th of a second. This value of current is well below heart fibrillation levels."

Looking about on the web I found a 8 dollar box from a well know vendor for testing gfci's.

"Tester trips between 6-9 mA" No mention as to the time required to trip.

This box might do a great job for what it was designed to do, how ever I do not call it a tester, a tripper yes, tester no. My point is most people using these cheap devices are doing themselves and clients a disservice.

I have not looked recently (last 3 years) since I got out of the business. Someone may have come up with a device that really does test, current and time. Bet my government check it is not inexpensive.

...

Continue reading at AFCI GFCI WIRING, TESTING & SAFETY or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see AFCI GFCI TESTING & SAFETY FAQs - questions & answers posted originally at this page

Or see this

Article Series

  • AFCIs ARC FAULT CIRCUIT INTERRUPTERS
  • ELECTRICAL TOOLS BASIC - including plug-in receptacle testers & other tools
  • FREEZE-PROOF A BUILDING where we describe GFCI protection on heat tape circuits
  • GFCI PROTECTION, GFCI CODES
    • AFCI GFCI WIRING, TESTING & SAFETY
    • AFCIs vs. GFCIs
    • GFCI DEVICE SELECTION & WIRING
    • GFCI TEST PROCEDURES
    • MOBILE HOME ELECTRICAL GFCI DIAGNOSIS
  • GROUND SYSTEM INSPECTION
  • SAFETY for ELECTRICAL INSPECTORS - home
  • TEST EQUIPMENT, ELECTRICAL GUIDE

Suggested citation for this web page

GFCI TEST PROCEDURES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Share this article

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to ELECTRICAL INSPECTION & TESTING

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like. You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.

Comment Form is loading comments...

IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING. In any case you are welcome to send an email directly to us at InspectApedia.com at [email protected]

We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.

Citations & References

In addition to any citations in the article above, a full list is available on request.

  • UL 943, Ground-Fault Circuit Interrupters, retrieved 2016/08/08, original source: http://ulstandards.ul.com/standard/?id=943 Excerpt: 1.1 This Standard applies to Class A, single- and three-phase, ground-fault circuit-interrupters intended for protection of personnel, for use only in grounded neutral systems in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code, C22.1 (CEC), and Electrical Installations (Use), NOM-001-SEDE. These devices are intended for use on alternating current (AC) circuits of 120 V, 208Y/120 V, 120/240 V, 127 V, or 220Y/127 V, 60 Hz circuits. Note: In Canada, the text "intended for protection of personnel" is excluded.
  • NEMA, "Understanding GFCIs, Developed by the NEMA 5PP Personnel Protection Technical Committee" [Power Point Presentation], (2012)retrieved 2016/08/08, original source: https://www.nema.org/Products/Documents/NEMA-GFCI-2012-Field-Representative-Presentation.pdf
  • Antman, Steve, Roger Nolter, and Danny Liggett. "New rules for ground fault circuit interrupters." In 2011 IEEE IAS Electrical Safety Workshop, pp. 1-4. IEEE, 2011.
  • El-Sherif, Nehad, Rick Mendler, John Trotte, and Ajay Pathak. "Ground fault protection of personnel in industrial locations using the new UL 943C." In 2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC), pp. 409-414. IEEE, 2014, retrieved 2016/08/08, original source: http://www.csemag.com/single-article/ul-s-new-gfci-classes/89c8746cdc4a7fd8a3cb93f1d51ba57a.html
  • LaRocca, Robert L. "Personnel Protection devices for use on appliances." IEEE transactions on industry applications 28, no. 1 (1992): 233-238.
  • Neitzel, Dennis K., and Timothy L. Gauthier. "Ground fault protection-GFCI or GFPE-there is a difference." In Electrical Safety Workshop (ESW), 2013 IEEE IAS, pp. 207-210. IEEE, 2013.
  • Smoot, Arnold W. "GFCI---Applications and Alternatives." IEEE Transactions on Industry Applications 1 (1975): 56-61.
  • Wills, John H., Jan Ehrenwerth, and Dan Rogers. "Electrical injury to a nurse due to conductive fluid in an operating room designated as a dry location." Anesthesia & Analgesia 110, no. 6 (2010): 1647-1649.
  • Electrical shock injury statistics: www.healthatoz.com - September 2008;

    High-tension current generally causes the most serious injuries, although fatal electrocutions may occur with household current (e.g., 110 V in the United States and Canada and 220 V in Europe, Australia, and Asia). Contact with alternating current at 60 cycles per second (the frequency used in most US household and commercial sources of electricity) may cause tetanic skeletal muscle contractions, preventing self-release from the source of the electricity and thereby leading to prolonged exposure. The repetitive frequency of alternating current also increases the likelihood of current flow through the heart during the relative refractory period (the "vulnerable period") of the cardiac cycle. This exposure can precipitate ventricular fibrillation (VF), which is analogous to the R-on-T phenomenon.-- circ.ahajournals.org - September 2008

  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Mr. Cramer serves on the ASHI Home Inspection Standards. Contact Mark Cramer at: 727-595-4211 [email protected]
  • "Frequency of Occurrence and Sources of Rust and Corrosion in Electrical Panels," Daniel Friedman, IEEE HOLM Conference, Philadelphia PA, 1992 - see ELECTRIC PANEL RUST for an online version of this article.
  • Jim Simmons: Personal communication, J. Simmons to Daniel Friedman, 9/19/2008. Photographs contributed to this website by Jim P. Simmons, Licensed Electrician, 360-705-4225 Mr. Electric, Licensed Master Electrician, Olympia, Washington Contact Jim P. Simmons, Licensed Master Electrician, Mr. Electric, 1320 Dayton Street SE Olympia, WA 98501, Ph 360-705-4225, Fx 360-705-0130 [email protected]
  • Kenneth Kruger: Original author of the sidebar on testing VOM DMM condition: Kenneth Kruger, R.A., P.E. AIA ASCE, is an ASHI Member and ASHI Director in Cambridge, MA. He provided basis for this article penned by DJ Friedman.
  • "How to Use DMM's Safely," Leonard Ogden, CEE News, 888 Seventh Ave., New York, NY 10106, Dec 1990 p.10.
  • Dr. Jess Aronstein, consulting engineer, Poughkeepsie NY, 1991 [email protected]
  • Rex Cauldwell, master electrician and contributor to the Journal of Light ConstructionOn electrical topics
  • In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggestedCONTINUE READING or RECOMMENDED ARTICLES.
  • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: [email protected]. Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The HOME REFERENCE BOOK - the Encyclopedia of Homes and to use illustrations from The ILLUSTRATED HOME . Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.
ADVERTISEMENT
InspectAPedia.com HOME ABOUT ASK a QUESTION CONTACT CONTENT USE POLICY DESCRIPTION POLICIES PRINT PRIVACY
© 2026 - 1985 Publisher InspectApedia.com - Daniel Friedman

Tag » How To Test A Gfci Outlet