HVAC Rules of Thumb

If you’ve been in the HVAC industry for a while, you probably have some “Rules of Thumb” that you use throughout your day. Here are a few that you may not have used before and could prove to be useful!

The 1.7X rule

This rule of thumb states that the MAX heating capacity required for your comfort cooling application is 1.7 x the cooling load. For example, if the cooling required is 30 tons (360,000 btus), then the MAX heating capacity required would be 612,000 btus (1.7 x 360,000). This assumes no lighting, no people, no internal heat gain, and a -10 degF ambient design temperature. The heating requirement could be more, though it is extremely rare.

300 sq ft per ton

If you need a ROUGH estimate on how much comfort cooling a commercial building needs, this is a good place to start. The cooling requirements depend on many factors (insulation, population density, window type, internal equipment, lighting, etc), so use this rule of thumb carefully.

150 cfm per ton for makeup air (DOAS)

If a portion of your building needs makeup air (100% outdoor air), the amount of cfm PER ton is about 150. For example, a 15,000 cfm makeup air unit with cooling (or a DOAS unit), would require roughly 100 tons of cooling. 

0.1 tons/person in densely populated zones

This is a handy rule of thumb for estimating the cooling load for a densely populated area, like an auditorium, gymnasium or sanctuary. For example, if an auditorium will have up to 400 people at maximum capacity, the cooling load would be close to 40 tons (400 x 0.1). If the space is insulated well, this rule of thumb reduces a bit to 0.08 tons per person.

50 heating btuh per square ft

Just like all rules of thumb, this is just a place to start, and will heavily depend on insulation factors and heat generating equipment. In reality, most commercial buildings (offices, retail, schools) are probably closer to 25-35 btuh per square foot, but warehouses or areas with more ventilation could require 50-75 btuh per square ft (or sometimes even more!). This also depends where in the country or world you are. In the midwest this is a good rule of thumb. If you are in southern California, or in the arctic circle, this rule of thumb is not so helpful.

1.3 cfm per sq ft

If you need to quickly determine how much cfm you need to deliver to a space, this is a great place to start. If the cooling load is relatively small, the system may require closer to 1 cfm/sq ft. In spaces that are more density populated, like conference rooms, gymnasiums or auditoriums, the space may require closer to 2 cfm per sq ft (or sometimes more!)

Are these useful?

What are some rules of thumb that you use every day?

  • Author
  • Recent Posts
Brad Telker Connect on:Brad TelkerVice President of Sales, Applied Systems Group at cfm Distributors, Inc.Brad was born and raised in St Louis Missouri, where he spent the first 18 years of his life. At the ripe young age of 18, he embarked onto his next big adventure, traveling to the University of Missouri Columbia for a bachelor’s degree in Mechanical Engineering. Brad joined the cfm team in 2006, and now as the Vice President of Commercial Sales, he focuses on business development, as well as helping contractors and engineers find creative and unique solutions to any size project. When he’s not at work, Brad enjoys photography, running and spending time with his family. Brad Telker Connect on:Latest posts by Brad Telker (see all)
  • Glycol Chiller & AHU Derates – January 5, 2021
  • No Data Tag, No Problem – July 28, 2020
  • Design Tips for Sound Sensitive Applications – July 6, 2020

Related Posts:

  • How to design a DOAS unit as sole source heating and coolingHow to design a DOAS unit as sole source heating and cooling
  • How many tons of air conditioning is this DX or Chilled Water coil?How many tons of air conditioning is this DX or…
  • ARE YOU READY? Commercial Package Rooftop Unit Regulatory Changes Are Coming!ARE YOU READY? Commercial Package Rooftop Unit…
  • Airside economizers: Are they required on your project and are they a good investment?Airside economizers: Are they required on your…
  • York’s Modulating Heat Pumps – The NEXT Thing for Ground Source Contractors!  What?York’s Modulating Heat Pumps – The NEXT Thing for…
  • Supercharge your home energy savingsSupercharge your home energy savings

Tag » What Is Cfm In Hvac