Loose Toilet Repair Procedure

InspectAPedia® - Search InspectApedia

InspectAPedia®

FREE Encyclopedia of Building & Environmental Construction, Diagnosis, Maintenance & Repair The accuracy & trustworthiness of every article or Q&A is researched by human experts. See WHO ARE WE?

Question? Just ask us!

Google InspectAPedia
  • HOME
  • SEARCH
  • AGE OF BUILDING +
    • AIR CONDITIONER & HEAT PUMP
    • BUILDING AGE- home
    • ARCHITECTURE - home
    • BULBS & CONNECTORS
    • CHIMNEYS & FIREPLACES
    • DOOR HARDWARE
    • DRYWALL, FIBERBOARD, PLASTER - home
    • ELECTRICAL RECEPTACLES
    • ELECTRICAL SYSTEMS
    • ELECTRICAL WIRING
    • FLOORING
    • FOUNDATION
    • FRAMING
    • HEATING EQUIPMENT
    • HEATER, BOILER, FURNACE
    • HISTORIC BUILDINGS
    • HVAC
    • INSULATION
    • KIT HOMES
    • LOG CABIN
    • NAILS SPIKES BOLTS - home
    • PLASTER
    • PLUMBING
    • PORCHES
    • ROOFING MATERIALS
    • SAW & AXE CUTS
    • SEPTIC SYSTEM
    • SIDING MATERIAL
    • WATER HEATER
    • WINDOWS & DOORS
  • AIR CONDITIONING +
    • A/C WON'T START
    • AGE of HVAC
    • AIR FILTERS - home
    • AIR HANDLER - home
    • BLOWER FAN
    • COMPRESSOR / CONDENSER - home
    • CONTROLS & SWITCHES
    • DIAGNOSTIC GUIDES
    • DUCT SYSTEM - home
    • EDUCATION COURSES
    • EVAPORATIVE COOLING
    • HARD START COMPRESSOR
    • HEAT PUMP
    • HEATING SYSTEM - home
    • MANUALS & PARTS - home
    • OPERATING COST
    • OPERATING TEMPERATURE
    • REFRIGERANT
    • REPAIR GUIDES- home
    • SPLIT SYSTEM - home
    • THERMOSTATS- home
    • VENTILATION - home
  • APPLIANCES +
    • ASBESTOS
    • CLOTHES DRYER
    • CLOTHES DRYER VENT
    • COFFEE MAKER
    • DISHWASHER
    • DOORBELL
    • EFFICIENCY RATINGS
    • ELECTRIC MOTOR
    • EXHAUST FAN
    • GARBAGE DISPOSER
    • GAS FIREPLACES LOGS
    • MICROWAVE
    • NOISE
    • OVEN DOOR
    • RANGE COOKTOP OVEN - home
    • REFRIGRATOR
    • THERMOCOUPLE
    • THERMOSTATS
    • TRASH COMPACTOR
    • VACUUM CLEANER
    • WASHING MACHINE
    • WASHING MACHINE vs SEPTIC
    • WATER HEATER
    • WINDOW / WALL AIR CONDITIONER
  • ARCHITECTURE +
    • AGE of a BUILDING
    • ARCHITECTURE ID - home
    • ARCHITECTURE STYLE & AGE
    • BUILD YOUR DREAM HOME
    • CHIMNEY
    • DEFINITIONS
    • DICTIONARY
    • HISTORIC & OLD BUILDINGS
    • HOUSE PARTS
    • KIT HOMES
    • MANUFACTURED HOME, DOUBLEWIDE
    • MOBILE HOME
    • MODULAR HOME
    • ROOF STYLE
    • ROOF DORMER
    • SIDING
    • WINDOWS
  • CODES +
    • ACCESS RESTRICTIONS
    • AFCI GFCI
    • CONCEALED SPACE FIRE
    • CRAWL SPACE VENTILATION
    • DANGEROUS CONDITIONS
    • ELECTRICAL
    • ELEVATOR & STAIR LIFT
    • FIRE RATING ROOF SURFACES
    • FRAMING TABLES, SPANS
    • GRABRAIL GRAB BAR
    • HANDRAIL
    • LIGHTING
    • MOBILE HOME
    • MOBILE OFFICE
    • RAILING - home
    • RETAINING WALL GUARDRAIL
    • ROOFING
    • SAFETY HAZARDS
    • STAIRS - home
    • SEPTIC DESIGN U.S.A.
    • SEPTIC & SEWAGE CODES
    • VENTILATION
  • CHIMNEY +
    • ABANDONED
    • BRACKET & GALLOWS
    • CRACK
    • DIRECT / SIDE WALL VENTS
    • DRAFT
    • FIRE CLEARANCES
    • FIREPLACES & HEARTHS - home
    • FLASHING
    • FLUE INSPECTION
    • FLUE SIZE
    • FLUE TILE DAMAGE
    • HEIGHT
    • INSPECTION
    • LEANING, MOVEMENT
    • MASONRY CHIMNEY - home
    • METAL CHIMNEYS & FLUES - home
    • RAIN CAP
    • RE-LINING
    • REPAIR
    • STAINS & LEAKS
    • UNLINED FLUES
    • WOOD STOVES - home
  • DAMAGE +
    • ANIMAL DAMAGE
    • DISASTER INSPECT REPAIR - home
    • EARTHQUAKE - home
    • FLOOD - home
    • FLOOD REPAIR PRIORITIES
    • HURRICANE DAMAGE
    • MOLD PREVENTION
    • ROOF DAMAGE, WIND
    • SALVAGE BUILDING CONTENTS
    • SINKHOLES, WARNING SIGNS
    • STORM-RESISTANT WINDOWS
    • STRUCTURAL INSPECTIONS
    • WILDFIRE DAMAGE
    • WIND DAMAGE
  • ELECTRIC +
    • AFCIs
    • ALUMINUM WIRING - home
    • AMPS VOLTS
    • BACK-WIRED DEVICES - home
    • BACKUP GENERATORS
    • BATHROOM FAN
    • BULBS - home
    • BX WIRING
    • CAPACITORS for MOTORS
    • CEILING LIGHT
    • CIRCUIT BREAKER FAILURE
    • CIRCUIT BREAKER / FUSE INSPECT
    • CIRCUIT ID, MAP & LABEL
    • CLEARANCES
    • COMPRESSOR MOTOR CAPACITOR
    • CONDUIT
    • COPPER-CLAD ALUMINUM WIRE
    • DEFINITIONS
    • DISTRIBUTION PANEL
    • DMM MULTIMETER
    • ELECTRICAL BOX
    • ELECTRICAL CODE BASICS
    • ELECTRICITY LOSS / FLICKERING LIGHTS
    • FEDERAL PACIFIC FPE- home
    • FLUORESCENT LIGHT
    • GENERATORS
    • GFCI
    • GROUND SYSTEM - home
    • KNOB & TUBE WIRING
    • LIGHTING, EXTERIOR - home
    • LIGHTING, INTERIOR - home
    • LOW VOLTAGEWIRING
    • METERS & BASES
    • MOTOR REPAIR - home
    • MOTOR WIRE SIZE
    • MULTI-WIRE CIRCUITS
    • NOISES, ELECTRICAL
    • OLD HOUSE ELECTRIC- home
    • OUTLET, WIRE - home
    • PANEL- home
    • RELAY SWITCHES
    • SAFETY
    • SERVICE ENTRY- home
    • SPLICE
    • THERMAL IMAGING
    • TURN BACK ON
    • ZINSCO SYLVANIA
  • ENERGY +
    • AIR CHANGE RATE
    • AIR LEAKS - home
    • AIR LEAKS RETURN DUCTS
    • AIR LEAKS SUPPLY DUCTS
    • BASEMENT HEAT LOSS
    • BIO-FUEL
    • BLOWER DOORS
    • DUCT SYSTEM
    • ENERGY AUDIT
    • ENERGY RETROFIT
    • ENERGY SAVINGS PRIORITY
    • ENERGY USE MONITOR
    • HEAT COST SAVINGS
    • HEAT LOSS INDICATORS
    • HIGH MASS TRADEOFFS
    • ROOF COLOR
    • R U & K VALUE
    • SEER RATING
    • SOLAR ENERGY
    • TIMERS
    • VENTILATION, HEAT COST
    • WATER HEATER TIMER
    • WIND ENERGY
    • WINDOW EFFICIENCY
  • ENVIRONMENT +
    • AIR POLLUTANTS
    • ALLERGENS +
    • ALLERGEN TESTS
    • ARSENIC HAZARDS
    • ASBESTOS HAZARDS
    • ASBESTOS IDENTIFICATION - home
    • ASBESTOS in THIS MATERIAL?
    • ASBESTOS LIST of PRODUCTS
    • ASBESTOS PHOTO GUIDE
    • BACKUP, SEPTIC-SEWAGE
    • BACTERIA, MOLD, POLLEN
    • BANNED ASBESTOS PRODUCTS
    • BEDBUGS
    • BIOLOGICAL POLLUTANTS
    • CEILING TILE ASBESTOS ID
    • CELL PHONE RADIATION
    • CHINESE DRYWALL
    • DISINFECTANTS, SANITIZERS, SEALANTS
    • ELECTROMAGNETIC FIELDS
    • FIBERGLASS HAZARDS
    • FIBERGLASS INSULATION MOLD
    • FIBERGLASS SHEDDING
    • FIBERGLASS CONTAMINANTS
    • FLOOR TILE ASBESTOS
    • FORMALDEHYDE HAZARDS
    • GAS DETECTION
    • HAZARD vs RISK
    • HOUSE DUST
    • INDOOR AIR QUALITY IAQ
    • MOLD CONTAMINATION
    • MOLD / ENVIRONMENT EXPERT
    • MORGELLONS SYNDROME
    • MYCOTOXIN EFFECTS
    • NOISE DIAGNOSIS
    • ODOR DIAGNOSIS
    • PESTICIDE EXPOSURE
    • POPCORN CEILING ASBESTOS
    • SEWAGE CONTAMINATION
  • EXTERIOR +
    • BRICK WALL WEEP HOLES
    • DECK & PORCH CONSTRUCT - home
    • DOORS, EXTERIOR
    • FIBER CEMENT SIDING - home
    • FLASHING on BUILDINGS - home
    • PAINT FAILURE
    • LIGHTNING PROTECTION
    • PAINT FAILURE - home
    • RAMPS, ACCESS - home
    • SHEATHING, FIBERBOARD
    • SLIP TRIP & FALL HAZARDS
    • STAIR CONSTRUCTION - home
    • STAIR DIMENSIONS
    • STUCCO WALL METHODS
    • WINDOWS & DOORS, AGE, TYPES
  • HEAT +
    • AGE of A/C & HEAT PUMPS
    • AGE of HEATER, BOILER, FURNACE
    • AIR FILTERS f- home
    • AIR HANDLER / BLOWER UNIT - home
    • AQUASTAT CONTROL - home
    • BACKDRAFTING
    • BACKUP HEAT for HEAT PUMPS
    • BANGING HEAT SYSTEM NOISES
    • BANGING HEAT ZONE VALVES
    • BANGING PIPES RADIATORS
    • BUZZING NOISE
    • BASEBOARD HEAT REPAIR - home
    • BLOWER FAN
    • BOILERS - home
    • CAD CELL RELAY
    • CHECK VALVES
    • CIRCULATOR PUMPS- home
    • CLEARANCE DISTANCES
    • COMBUSTION AIR
    • CONDENSING BOILERS/FURNACES
    • CONTROLS & SWITCHES
    • CONVECTOR HEATERS
    • DAMPERS & DRAFT REGULATORS
    • DATA TAGS
    • DIAGNOSE & FIX A/C / HEAT PUMP
    • DIAGNOSE & FIX BOILER - home
    • DIAGNOSE & FIX FURNACE - home
    • DIRECT VENT / SIDE WALL VENT
    • DRAFT REGULATORS / HOODS, GAS
    • DRAFT MEASUREMENT
    • DRAFT REGULATOR
    • DUCT SYSTEM - home
    • ELECTRIC HEAT - home
    • EVAPORATIVE COOLING SYSTEM
    • EXPANSION TANK, BOILER - home
    • FAN, AIR HANDLER BLOWER - home
    • FAN LIMIT SWITCH - home
    • FILTERS, AIR
    • FILTERS, OIL
    • FIRE SAFETY CONTROLS
    • FIREPLACES & HEARTHS - home
    • FLUE SIZE
    • FURNACE CONTROLS
    • FURNACES, HEATING - home
    • GAS BURNER FLAME & NOISE
    • GAS BURNER PILOT LIGHT
    • GEOTHERMAL HEAT
    • HEAT PUMP REPAIR - home
    • HEAT LOSS DIAGNOSIS-BOILERS
    • HEAT LOSS DIAGNOSIS-FURNACES
    • HEAT WON'T TURN OFF
    • HEAT WON'T TURN ON
    • HEATING COST SAVINGS
    • HEATING OIL- home
    • HEATING SYSTEM NOISE
    • HUMMING NOISE
    • LIFE EXPECTANCY A/C / HEAT PUMP
    • LIFE EXPECTANCY FAN / WALL CONVECTOR
    • LIFE EXPECTANCY FURNACE
    • LOW VOLTAGE WIRING
    • MANUALS
    • MINI SPLIT A/C & HEAT PUMPS
    • MOBILE HOME HEAT
    • NO HEAT - BOILER
    • NO HEAT - FURNACE
    • OIL STORAGE TANKS
    • OPERATING TEMPERATURES
    • PORTABLE ELECTRIC HEATER
    • RADIANT HEAT
    • STEAM HEAT
    • THERMOSTATS - home
    • THERMOSTAT WIRING
    • ZONE VALVES
  • INSPECTION +
    • ADVANCED METHODS
    • CARPENTER ANTS
    • CARPENTER BEES
    • DISASTER INSPECTION- home
    • DUST SAMPLING
    • FEAR-O-METER: Dan's 3 D's SET REPAIR PRIORITIES
    • FIBER & HAIR IDENTIFICATION
    • FIBERGLASS PARTICLE
    • FIRE OFF-GASSING
    • FORENSIC INVESTIGATION
    • GAS TEST PROCEDURES
    • HISTORIC & OLD BUILDINGS
    • HOUSE DUST ANALYSIS
    • INSECT INFESTATION - home
    • LIGHT, GUIDE to FORENSIC USE
    • LIGHT, UV BLACK LIGHT USES
    • MICROSCOPY
    • STRUCTURAL DAMAGE PROBING
    • TERMITE DAMAGE
    • THERMAL EXPANSION
  • INDOOR AIR +
    • AIRBORNE MOLD LEVEL
    • AIRBORNE PARTICLE ANALYSIS
    • ALLERGEN TESTS
    • ANIMAL ALLERGENS DANDER
    • CARBON DIOXIDE
    • CARBON MONOXIDE
    • CARPETING
    • CAT DANDER
    • COMBUSTION GASES
    • DUST SAMPLING
    • EMERGENCY RESPONSE, IAQ, GAS, MOLD
    • FIBERGLASS - home
    • HUMIDITY
    • IAQ & HOUSE TIGHTNESS
    • INDOOR AIR HAZARDS
    • ODORS GASES SMELLS- home
    • VENTILATION
  • INSULATION +
    • ATTIC
    • BASEMENT
    • FIBERGLASS
    • FRAMING DETAILS
    • HOT ROOF PROBLEMS
    • INSULATION AIR & HEAT LEAKS
    • INSULATION CHOICES
    • INSULATION FACT SHEET- DOE
    • INSULATION GREENHOUSE
    • INSULATION ID
    • INSULATION LOCATION
    • INSULATION MOLD
    • INSULATION R-VALUES
    • POLYSTYRENE FOAM
    • RIGID FOAM
    • UFFI UREA FORMALDEHYDE FOAM
  • INTERIOR +
    • ASBESTOS in DRYWALL
    • BATH & KITCHEN DESIGN - home
    • CABINETS & COUNTERTOPS - home
    • CARPETING - home
    • CARPET STAIN ID
    • CEILING STAIN DIAGNOSIS
    • CERAMIC TILE FLOOR, WALL
    • CONDENSATION
    • COUNTERTOPS
    • DRYWALL FIBERBOARD PLASTER- home
    • EFFLORESCENCE WHITE DEPOSIT
    • FIBERBOARD- home
    • FIREPLACES & HEARTHS
    • FLOOR, CONCRETE SLAB
    • FLOOR TYPES & DEFECTS - home
    • INTERIOR FINISHES
    • KITCHEN DESIGN
    • MOISTURE CONTROL
    • PAINT FAILURE - home
    • PLASTER METHODS
    • RESILIENT SHEET FLOORING - home
    • SHEATHING, FIBERBOARD
    • SHEET FLOORING ID
    • SLIP TRIP & FALL
    • STAIR CONSTRUCTION
    • STAIN DIAGNOSIS
    • STUCCO WALL METHODS
    • THERMAL TRACKING
    • TILED SURFACES
    • TRIM, INTERIOR
    • WALL FINISHES
    • WOOD STOVE OPERATION - home
    • WOOD FLOOR DAMAGE
  • MOBILE HOME +
    • BUYERS ADVICE
    • CODES & MANUALS
    • COMBUSTION AIR SAFETY
    • CONNECTIONS, MULTI-WIDE
    • COOLING SYSTEM
    • CRAWL SPACES
    • CROSSOVER CONNECTORS
    • DATA TAGS & LABELS
    • DEMOLISH REMOVE MOVE
    • ELECTRICAL POWER LOST
    • ELECTRICAL SYSTEM
    • EMERGENCY EGRESS WINDOWS
    • ENERGY ZONES
    • EXTERIOR DEFECTS
    • FLICKERING LIGHTS
    • FOUNDATIONS
    • GFCI DIAGNOSIS
    • HEALTH DEPARTMENT HELP
    • HEATING SYSTEM
    • INSPECTIONS
    • INSULATION & VENTILATION
    • INTERIOR DEFECTS
    • LEAKS
    • MODULAR CONSTRUCTION
    • MOLD CONTAMINATION
    • PIERS
    • PLUMBING
    • ROOF
    • SAFETY
    • SKIRTING
    • STABILIZING & TIE DOWNS
    • STRUCTURE
    • TEMPORARY OFFICE TRAILER
    • WALL DEFECTS
    • WATER HEATERS
    • WIND RATINGS
    • WINTERIZE
  • MOLD +
    • ACTION GUIDE
    • AIRBORNE MOLD COUNT - home
    • AIRBORNE PARTICLE LEVEL- home
    • ASPERGILLOSIS
    • ATTIC MOISTURE or MOLD
    • BLACK MOLD, HARMLESS
    • BLEACHING MOLD
    • BOOK / DOCUMENT MOLD
    • CABINET MOLD
    • CACTUS FUNGI / MOLD
    • CAR MOLD CONTAMINATION
    • CARPET MOLD / ODOR TESTS
    • CAR MOLD CONTAMINATION
    • CEILING STAIN DIAGNOSIS
    • DIRT FLOOR MOLD
    • DRYWALL MOLD
    • DUST / MOLD SAMPLING
    • EFFLORESCENCE & WHITE DEPOSITS
    • EMERGENCY RESPONSE
    • FEAR of MOLD - MYCOPHOBIA
    • FIBERBOARD SHEATHING MOLD
    • FIBERGLASS INSULATION MOLD
    • FIND MOLD, ESSENTIAL STEPS
    • FOXING STAINS
    • HARD TO SEE MOLD, SPOTTING
    • HIDDEN MOLD
    • HUMIDITY CONTROL & TARGETS
    • LIGHT, USE TO FIND MOLD
    • MERULIPORIA FUNGUS
    • MILDEW
    • MOBILE HOME MOLD
    • MODULAR HOME MOLD
    • MOLD A COMPLETE GUIDE - home
    • MOLD SAFETY ADVICE for TENANTS
    • MOLD CLEANUP
    • MOLD AGE
    • MOLD APPEARANCE
    • MOLD CLEARANCE INSPECTION
    • MOLD COUNT NUMBERS
    • MOLD CULTURE SAMPLING
    • MOLD DETECTION
    • MOLD DOCTOR
    • MOLD ENVIRONMENTAL EXPERTS
    • MOLD EXPOSURE STANDARDS
    • MOLD FREQUENCY
    • MOLD INVESTIGATION PROCEDURE
    • MOLD ODORS, MUSTY SMELLS
    • MOLD PREVENTION - home
    • MOLD RELATED ILLNESS
    • MOLD SANITIZER, SPRAY, BIOCIDE
    • MOLD TEST PROCEDURES
    • MVOCs & MOLDY MUSTY ODORS
    • MYCOTOXIN EFFECTS
    • OZONE TREATMENT WARNING
  • NOISE +
    • BANGING BOOMING NOISES - home
    • ELECTRICAL SYSTEM NOISE
    • FAN NOISES
    • HEATING SYSTEM NOISE
    • HVAC SYSTEM NOISE
    • NOISE CONTROL for ROOFS
    • PLUMBING SYSTEM NOISE - home
    • RELAY SWITCH NOISE
    • ROOF IMPACT NOISE
    • ROOF NOISE TRANSMISSION - home
    • SOUND CONTROL
    • TEMPERATURE CHANGE & ROOF NOISE
    • WATER HAMMER NOISE
  • ODOR +
    • AIR CONDITIONING
    • ANIMAL or URINE
    • CAR ODORS, ANIMALS
    • FLOOR DRAIN / TRAP
    • METHANE & SEWER GAS
    • MOLD ODORS
    • MVOCs MOLDY MUSTY
    • ODOR CONTROL for SEPTIC
    • ODORS FROM HEATING SYSTEMS
    • ODORS, PLUMBING SYSTEM
    • ODORS, SEPTIC or SEWER
    • ODOR SENSITIVITIY
    • OZONE MOLD / ODOR TREATMENT
    • PLUMBING SYSTEM - home
    • SMELL PATCH FIND ODOR SOURCE
    • URINE ODOR SOURCE
    • WATER ODOR CURE
  • PLUMBING +
    • AIR DISCHARGE at FAUCETS
    • CHECK VALVES
    • CLEARANCE DISTANCES
    • CLOGGED DRAIN REPAIR
    • COMPOSTING TOILETS
    • DISPOSABLE WET WIPE CLOGS
    • DRAIN CLEANOUTS
    • FLOOR DRAIN / TRAP ODORS
    • GAS TANKS & PIPING
    • OIL TANKS & PIPING
    • PLUMBING TRAPS
    • PLUMBING VENTS - home
    • SEPTIC SYSTEMS
    • SEWAGE PUMPS - home
    • TANKLESS COIL HOT WATER
    • TOILETS - home
    • WATER HEATERS, ELECTRIC - home
    • WATER PIPE CLOG
    • WATER PRESSURE DIAGNOSE
    • WATER PRESSURE IMPROVE
    • WATER PRESSURE LOSS- home
    • WATER PUMPS & WELLS
    • WATER SHUTOFF VALVE
    • WATER SOFTENERS - home
    • WATER PIPING - home
    • WATER TANK - home
    • WINTERIZE A BUILDING
  • ROOF +
    • AGE
    • ASBESTOS & FIBER CEMENT - home
    • ASPHALT SHINGLES - home
    • CLAY TILE - home
    • CLEANING
    • COLOR
    • CONCRETE
    • CONTRACTOR, CHOOSE
    • CORRUGATED
    • DEBRIS STAINING
    • DISPUTE RESOLUTION
    • EPDM, RUBBER, PVC
    • EXTRACTIVE BLEEDING SHINGLES
    • FELT UNDERLAYMENT - home
    • FIBER CEMENT ROOFING - home
    • FIBERBOARD & FIBER-WOOD
    • FIRE RATINGS
    • FLASHING on BUILDINGS - home
    • FLAT ROOF LEAKS
    • HAIL DAMAGE
    • ICE DAM
    • INSPECTION
    • LEAD ROOFING & FLASHING
    • LEAK REPAIR - home
    • LOW SLOPE - home
    • MATERIALS, AGE, TYPES
    • MEMBRANE & SINGLE PLY
    • METAL- home
    • PLASTIC ROOFING TYPES
    • PVC, EPDM, RUBBER MEMBRANE
    • ROLL ROOFING, ASPHALT & SBS
    • RUBBER SHINGLES SLATES
    • SBS ROOFING ROLL & BUR ROOFS
    • SEALANTS & MASTICS
    • SHINGLE STORAGE
    • SLATE - home
    • SLOPE CALCULATIONS
    • STAINS - home
    • STANDARDS
    • STONE ROOF
    • THATCH ROOF
    • TILE, CLAY - home
    • TILES, CONCRETE
    • VENTILATION - home
    • WALKABLE
    • WARRANTIES
    • WHITE STAINS - home
    • WIND DAMAGE
    • WIND NOISES
    • WIND DAMAGE RESISTANT
    • WOOD SHAKE & SHINGLE - home
    • WORKMANSHIP & DAMAGE
  • SEPTIC +
    • AEROBIC ATUs - home
    • AGE of SEPTIC SYSTEM
    • BACKUP PREVENTION
    • BIOMAT FORMATION & SEPTIC LIFE
    • BOD WASTEWATER TEST
    • CAMERAS, SEWER / SEPTIC
    • CARE - home
    • CESSPOOLS
    • CHAMBER SEPTIC SYSTEMS
    • CLEARANCE DISTANCES
    • CLOGGED DRAIN REPAIR
    • CLOGGED DRAIN FIELD
    • CODES - home
    • COMMERCIAL SEPTIC
    • COMPONENT LOCATIONS - home
    • D-BOX INSTALL REPAIR
    • DESIGN ALTERNATIVES - home
    • DESIGN BASICS - home
    • DESIGN PREVENT FLOOD DAMAGE
    • DIFFICULT SEPTIC SITE
    • DISPERSAL METHODS
    • DISPOSAL vs TREATMENT
    • DRAINFIELD TEST - home
    • DRIVING OVER SEPTIC
    • DRYWELL
    • EFFLUENT DISTRIBUTION
    • EFFLUENT RETENTION TIME
    • FAILURE SIGNS
    • FILTERS
    • FLOODED SYSTEM REPAIR
    • FREEZE PROTECTION
    • FREEZE-UP SOLUTIONS
    • FROZEN AEROBIC SEPTIC
    • GARBAGE DISPOSAL vs SEPTICS
    • GRAVELLESS SEPTIC
    • GREYWATER SYSTEMS
    • HOOT AEROBIC SEPTIC
    • HOME BUYERS GUIDE
    • HOME SELLERS GUIDE
    • HOW SEPTIC SYSTEMS WORK
    • INSPECT & TEST - home
    • INSPECT & TEST LAWS
    • LAUNDROMAT WASTEWATER
    • LIFE EXPECTANCY
    • LOADING & DYE TEST - home
    • LOW COST SYSTEMS
    • MAINTENANCE - home
    • MEDIA FILTER SYSTEMS - home
    • ODOR CONTROL
    • ODORS, SEWER GAS
    • PLANTS OVER SEPTIC SYSTEMS
    • PUMPING the SEPTIC TANK
    • PUMPS
    • REPAIR - home
    • SAFETY
    • SANDY SOIL SYSTEMS
    • SEEPAGE PITS
    • SEWAGE BACKUP
    • SEWAGE CONTAMINANTS
    • SEWAGE TREATMENT PLANTS
    • SEWER CONNECTION? - home
    • TANKS - home
    • TANK CLEANING
    • TANK COVERS
    • TANK DEPTH
    • TANK, HOW TO FIND
    • TANK PUMPING
    • TANK PUMPING SCHEDULE
    • TANK TEES
  • STRUCTURE +
    • ADOBE CONSTRUCTION
    • BASEMENT WATERPROOFING
    • BLOCK FOUNDATION / WALLS - home
    • BRICK FOUNDATIONS & WALLS - home
    • BUILDING DAMAGE REPAIR
    • BULGED vs. LEANING FOUNDATIONS
    • CARPENTER ANTS
    • CHIMNEY REPAIR - home
    • CLAY HOLLOW TILE
    • CLEARANCE DISTANCES - topic home
    • COLUMNS & POSTS, DEFECTS
    • CONCRETE FOUNDATION, WALL, SLAB
    • CONTROL JOINT CRACKS
    • CRAWL SPACES
    • DAMAGE ASSESSMENT
    • DECK & PORCH - home
    • EARTHQUAKE, FLOOD, DISASTER
    • FIBERBOARD SHEATHING - home
    • FIRE ESCAPES & STAIRS
    • FIRE STOPPING
    • FOUNDATION TYPES
    • FOUNDATION CRACKS & DAMAGE- home
    • FOUNDATION REPAIR - home
    • FRAMING AGE, SIZE, SPACING, TYPES
    • FRAMING CONNECTORS
    • FRAMING DAMAGE REPAIR - home
    • FRAMING FASTENERS
    • FRAMING SQUARE - home
    • FRAMING TABLES, SPANS
    • HOUSEWRAP
    • INSECT DAMAGE - home
    • LOG HOME REPAIR
    • MOBILE HOMES
    • MODULAR CONSTRUCTION
    • MOISTURE CONTROL
    • PANELIZED CONSTRUCTION
    • PORCH CONSTRUCTION
    • ROOF BEND SAG COLLAPSE
    • ROOF FRAMING TIES & BEAMS
    • ROOF TRUSS UPLIFT
    • ROT TYPES
    • SHIPPING CONTAINER HOUSING
    • SINKHOLES / SUBSIDENCES
    • STAIRS, RAILINGS, LANDINGS, RAMPS - home
    • STRESS SKIN / SIPS
    • STRUCTURAL DAMAGE PROBING
    • TERMITE INSPECTION & DAMAGE
    • TIMBER FRAMING, ROT
    • TRUSSES, FLOOR & ROOF
    • TRUSS UPLIFT, ROOF
    • WATER ENTRY, LEAKS
    • WOOD STRUCTURE ASSESSMENT
  • VENTILATE +
    • ATTIC VENTILATION
    • BALANCED VENTILATION
    • BATHROOM VENT CODES - home
    • BATHROOM VENT DUCT ROUTING
    • KITCHEN VENT DESIGN
    • HIP ROOF VENTILATION
    • HOT ROOF PROBLEMS
    • ICE DAM PREVENTION
    • ROOF ICE DAM LEAKS
    • ROOF VENTILATION CODE- home
    • SKYLIGHT VENTILATION
    • SOFFIT VENTILATION
  • WATER +
    • AIR VOLUME CONTROLS
    • ARTESIAN WELLS, SPOOLS
    • CHECK VALVES
    • CHEMICAL CONTAMINANTS
    • CISTERNS
    • FOOT VALVES
    • GREYWATER SYSTEMS - home
    • NO WATER PRESSURE
    • ODORS
    • PUMP PRESSURE CONTROL
    • PUMPS
    • SPRINGS
    • SWIMMING WATER
    • WATER CONSERVATION- home
    • WATER CONTAMINATION - home
    • WATER FILTERS
    • WATER METERS
    • WATER ODORS
    • WATER POLLUTANTS
    • WATER PRESSURE BOOSTER
    • WATER PRESSURE LOSS - home
    • WATER PRESSURE REDUCER / REGULATOR
    • WATER PUMP PRESSURE CONTROL
    • WATER PUMP PRIMING
    • WATER PUMP REPAIR - home
    • WATER TANK REPAIR - home
    • WATER TESTS - home
    • WATER TREATMENT - home
    • WELLS CISTERNS & SPRINGS - home
  • CONSULT
  • ESTIMATE
  • CONTACT
Loose toilet fell over (C) Daniel FriedmanLoose Wobbly Toilet Repair Guide
  • POST a QUESTION or COMMENT about how to diagnose & fix a loose toilet

How to fix a loose toilet:

Here we explain how to diagnose and repair a loose, wobbly toilet.

A toilet that is loose is unsanitary and possibly unsafe. But worse, if it has rotted the bathroom floor or if the waste pipe flange below the toilet is damaged, repair can be more difficult (and expensive) unless you know these tricks of the trade.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

How to Repair a Loose, Leaky Toilet Mount

Plumbing drains (C) Carson Dunlop Associates

How to Securely Bolt the Toilet to the Floor or Waste Flange

This article series TOILET REPAIR GUIDE discusses the cause, diagnosis, and repair of toilet problems (water closet problems) such as a toilet that does not flush well, clogged toilets, slow-filling toilets, running toilets, loose wobbly toilets, and odors at leaky toilets. Here we explain how to diagnose and repair problems with toilets, leaks, flushes, odors, noises, running and wasted water.

[Click to enlarge any image]

Our page top photo shows ugly staining in a toilet bowl - strong evidence that this toilet has been running, wasting water, possibly flooding the septic system, and sometimes giving bad flush performance as well. Details are below.

Citation of this article by reference to this website and brief quotation for the sole purpose of review are permitted. Use of this information at other websites, in books or pamphlets for sale is reserved to the author.

Before launching into our series of articles on diagnosing and repairing toilet problems such as clogged toilets, toilets that don't flush properly, running or leaky or noisy toilets, toilet odors, and loose toilets, take a look at the simple connection between a typical reservoir-tank toilet and the soil stack (waste piping) in the Carson Dunlop Associates sketch (above left), and review our description of basic types of toilets

at TOILET TYPES, CONTROLS, PARTS.

Loose toilet fell over (C) Daniel Friedman

Loose toilets are more than a leak, source of sewer odors , and sewer gas hazard. A toilet that is poorly secured to the floor can actually be dangerous if it tips over, dumping its user onto the floor.

See LEAKY TOILET SEALS, ODORS from loose leaky toilet seals.

Should a toilet tip it is likely to break its water supply pipe, leading to building leaks and water damage, and its user could be injured by a fall or by broken toilet parts. If you do break a toilet supply riser pipe, turn off the water to the toilet immediately.

If the TOILET SUPPLY RISER SHUTOFF VALVE [photo] is stuck or not working, you'll have to turn off water at the main water shutoff for the building or at a shutoff supplying cold water to the bathroom.

Loose toilets are especially dangerous to people who have limited mobility and who have difficulty transferring between a wheelchair or walker and the toilet.

Our photo (left) shows a toilet tipped over and leaning on a nearby wall. You might notice that this is a bathroom undergoing gut renovation following a building flood - was it from a broken toilet water supply riser pipe?

For fire safety, that blue foam insulation on the foundation wall would not normally be left exposed in the building.

Can't I Just Tighten the Toilet Mounting Bolts?

Leaky toilet base (C) Daniel FriedmanIt is tempting to simply try tightening the toilet mounting bolts that secure the toilet either to the floor or to a flange connected to the top of the sewer pipe. And indeed if those components are in good condition, this repair may seem to fix the loose toilet problem.

But as we pointed out above, if a toilet has been loose and wobbly, it has usually compressed and spread its wax ring seal between the toilet base and the top of the waste pipe.

The result is a leak (photo at left), sometimes hidden, that sends unsanitary wastewater into the floor structure or into the ceiling below the toilet each time the toilet is flushed.

So a better loose toilet repair is to turn off water to the toilet, empty water from its tank and bowl, remove the toilet from the floor, remove and replace the old wax ring, and then BOLT THE TOILET [photo]securely to the TOILET MOUNTING FLANGE [photo] or floor.

Some toilet models use four bolts, two are connected to the waste pipe flange and two more lag bolts secure the toilet to the floor or subfloor.

What if the Toilet Mounting Flange is Broken or the Floor Below the Toilet is Damaged and the Bolts Won't Tighten?

Toilet  mounting flange (C) Daniel FriedmanThere are several fixes for this problem. If the floor around and below a toilet is badly damaged, the best repair is to remove the toilet, remove and replace the damaged subfloor and finish floor, and then reinstall the toilet, mounting it securely with its bolts and perhaps also with a thin bead of caulk around the toilet base for extra security.

Toilets that are intended to be secured by bolts connecting to a flange at the top of the waste pipe (photo at left) use a flat-headed T-bolt. The "T" is inserted into a slot in the toilet mounting flange, moved in a slot around the flange to the proper location, and the toilet is set over the protruding bolts and bolted down (with a new wax seal). If the toilet mounting flange at the top of the waste pipe is broken or worn so that it won't hold the toilet mounting bolts securely it may be possible to replace the "T" bolts with a toilet bolt ending in a lag screw, bolted into subflooring close to the flange.

If the subfloor does not provide enough purchase for a lag-screw toilet mounting bolt, or if the subfloor is soft, but yet the finish flooring outside the toilet footprint is in good condition, you may not want to tear out the whole bathroom floor to fix this condition.

If there is access to the floor around the toilet from below, perhaps by removing drywall from the ceiling of the room below the toilet, it is usually possible to cut two 3/4" thick solid core plywood braces that surround the waste pipe. Screw these flat plates to the underside of the subfloor below the toilet, and use longer lag-screws to reach through the old soft subfloor or flange and into the new solid repair material.

Alternatively, a four-bolt toilet may afford two more mounting positions to secure the toilet to the floor.

Toilet with tank lid on seat(C) Daniel FriedmanWe use a thin bead of caulk applied to a clean under-side of the edges of the toilet base, combined with careful cleaning of the floor around the toilet, to provide additional adhesion of the toilet to the finish floor when it is reinstalled.

Use just enough caulk to glue down the toilet, but not such a wide bead that later removal of the toilet will be difficult. To remove a glued toilet later, we use a utility knife to simply cut through this caulk bead.

Here is our list of toilet trouble diagnosis and repair articles. You will see that some toilet problems are fixed easily and right at the toilet by a simple adjustment, while others may not be the toilet's fault at all, and may need more thoughtful diagnosis and repair.

Taking off the toilet tank top: Some of these simple toilet diagnosis steps require that you look into the toilet flush tank on the back of the toilet.

Just lift the top off of the toilet tank and set it carefully aside on the floor where you won't break it or trip over it.

If you leave the tank top on the toilet seat (as we did for this photo) you're asking for trouble, and also, it's a bit in the way.

Our sketch below shows the parts you'll see inside the toilet tank. You may want to refer back to this drawing while reading the details of each class if individual toilet problems listed above and how they are detected, diagnosed, and repaired.

4 Floor & Toilet Flange Repair Options Depend on Degree of Floor Damage

Oatey twist-on toilet repair flange kit (C) InspectApediaQuestion: how do I repair a loose toilet leaky around the base if the floor around it is rotted?

2017/06/03 Anthony V.

After I flush the toilet my tile floor gets squishy and water comes through the grout. Please help could it be a broken flange or a bad wax ring

This Q&A were posted originally

at TOILETS REPAIR FAQs

Show here: the Oatey 43654 PVC Twist-N-Set Closet Flange: a device that lets you re-set a toilet where its original mounting flange has broken. This toilet mounting flange is designed to replace a cast-iron closet flange. Its gasket will expand to fit inside all three types of waste pipe service-weight, heavy-weight, and hubless waste pipes.

Reply:

Anthony,

At LEAKY TOILET SEALS, ODORS we explain that both wastewater and odors around a toilet might be due to a bad wax ring seal. If you catch this problem in time - that is, before the leaks have damaged the subfloor below, the repair is pretty easy - just replace the wax seal; but it's important to inspect the condition of the floor to permit selection of the proper repair method.

Watch out: never try to repair a loose leaky toilet by simply tightening its mounting bolts. Even if the toilet stops wobbling, the wax ring seal has been compromised and leaks into the floor are likely to continue.

Here are four cases of extent of repair needed around a loose, leaky toilet base.

1. Loose Toilet, Floor Intact: replace wax ring seal

If the toilet is simply loose or has a compressed wax ring, it gets removed, a new ring installed, and it's re-bolted to the floor securely.

2. Loose Toilet, Floor Intact (or not), Broken Flange: replace toilet flange & wax ring seal

Genova repair toilet flange for broken flange problem (C) InspectApediaBut if the flange is broken you may need to break away and remove the old flange and then install a new replacement flange that secures to the subfloor and that directs wastewater into the remaining waste pipe before replacing the toilet's wax ring and re-installing the toilet.

In this article we show two replacement toilet mounting flange kits, one from Oatey and another from Genova. Both of these toilet flange repair devics are designed to mount by being pushed into the existing waste pipe opening and screwed to sound subfloor.

You will need to mount the closet flange (toilet flange) so that

  • The smaller round screw openings are over sound, solid subflooring - to accept screws that secure the flange to the floor.
  • The slots into which the toilet mounting bolts will insert are located approximately at the left and right sides of the end position of the toilet base.

You'll notice that the Oatey offers a thick plastic flange and two pairs of toilet bolt slots; the Genova closet flange uses a thinner metallic outer ring. Either of these should fit successfully under nearly all floor-mount toilets. Culwell also offers 4" and 3" protecting toilet flanges suitable for this repair.

Other plumbing suppliers such as Jones Stephens offer traditional brass or cast-bronze replacement closet flanges like the model shown below. These flanges are also screwed to the subfloor but do not include a built-in funnel to direct wastewater into the waste pipe.

With a traditional cast brass or steel replacement toilet mounting flange you'll want to use a wax-ring seal that includes a sleeve: an intengral plastic or PVC funnel-shaped element that assures that all wastewater enters the waste pipe - our second illustration below.

Traditional brass closet flange for toilet repair (C) InspectApedia Toilet wax ring with integral waste pipe seal (C) InspectApedia

The Oatey flange offers four openings for screws to secure the flange to the subfloor while the Genova offers six screw positions. So your choice between these two may depend on how much good subfloor you have to accept mounting screws and on where that good subfloor is in relation to the end position of the sides of the toilet. Each product has its own advantages: more screw positions or more toilet bolt slots.

EverBilt toilet gasket includes a sleeve, wax ring, and toilet mounting flange (not visible) (C) InspectApedia.com

Above is a combination toilet mount, wax ring seal, and sleeve produced by Everbilt. The flange is not shown. More about toilet wax ring seals is at LEAKY TOILET SEALS, ODORS

Watch out: both the wax-ring with sleeve and the EverBilt wax-ring, sleeve, flange package shown above are examples of an "extra-thick" wax ring option. You need the extra-thick wax ring on some toilets whose ceramic bottom mating protrusion is recessed in the toilet base.

But you do not need the extra-thick wax ring seal on many toilets whose bottom protrusion is at or close to the bottom edge of the toilet base. Using a wax ring seal that is thicker than needed can, during toilet mounting, push blobs of wax right into the waste pipe opening, causing a partial blockage of the waste line and problems of poor toilet flush performance - a subtle problem that might be hard to diagnose if you miss this detail.

Toilet mounting flange in place (C) Daniel Friedman

Above: the toilet has been removed and most of the wax spud ring has been scraped away to prepare for the installation of a new spud ring and then bolting down the new toilet. I push the wax ring onto the toilet base itself and then set the toilet in place. That avoids pushing wax into the flush-opening into the toilet base.

The most troublesome case arises if the toilet has been leaking for a long time: the subfloor itself may be rotted - which is possible in the case you describe since you say the tile grout is damaged.

If that's the case the repair is a bit more work.

The steps involve one of the three remaining approaches discussed here.

3. Loose Toilet on Significantly-Damaged Floor & Subfloor: repair from above

  • Remove the toilet
  • Cut away floor and subfloor around the toilet waste pipe, removing flooring to expose the floor joists below, extending the size of the cutout to the *center* of floor joists on either side of the waste pipe so that we have a secure edge to screw down replacement subflooring before then continuing with the other repairs I just described above.
  • Install new subfloor to match thickness of adjoining original subfloor.
  • Install new floor covering as needed
  • Replace the toilet using new spud ring gasket (wax ring seal) and toilet mounting flange as needed.

Toilet leak damaged subfloor below (C) Daniel Friedman

4. Loose Toilet on Small Area of Damaged Subfloor: repair from below

On occasion I've found that the subfloor was rotted but only for a couple of inches right around the toilet flange. A perfectly functional repair can be made in this case without ripping out the existing floor and subfloor - particularly appealing if the existing floor tile is still sound. For this situation I take the following steps: [Click to enlarge any image]

Area to add support below bad subfloor under leaky toilet (C) Daniel Friedman

  • remove the ceiling below the toilet in an area large enough to work around the toilet base - typically at least 24" square. I cut away ceiling to the center of nearby floor joists to make replacement of ceiling drywall easy.
  • cut a square or really a rectangle that I will then saw in half to form a repair patch to be placed around the waste pipe from below.
  • You will end with two pieces of 3/4" solid plywood underlayment that fit between the floor joists between which the toilet waste pipe runs. Using a jig saw we can cut half-round cutouts to fit the repair patch of subfloor around and quite close to the waste pipe.
  • The repair patch of subfloor has to be large enough that it can be screwed to sound subflooring that remains around the toilet waste pipe.
  • The repair patch, to be applied from below, is screwed "up" into sound subfloor around the toilet using stainless steel or galvanized construction screws short enough that they won't push up the finished-flooring above.
  • I add cleats along the floor joist sides just below the patch for added support to my patch
  • With the from-below subfloor reinforcement we are in essence providing a sound subfloor into which the toilet mounting lag bolts can extend from above - so you will need longer toilet mounting bolts that can pass past the soft or rot-area of the original subfloor and into and even a 1/4" or more through the 3/4" thick from -below solid plywood patch.

...

Continue reading at TOILET INSTALLATION PROCEDURE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

  • BLOCKED DRAIN REPAIR
  • CLOGGED DRAIN DIAGNOSIS
  • PLUMBING LEAK DETECTION METHODS
  • PLUMBING LEAK DETECTION & SHUTOFF DEVICES
  • SEWER GAS ODORS
  • TOILETS, INSPECT, INSTALL, REPAIR - home
    • FLUSHOMETER VALVES for TOILETS URINALS
    • LEAKY TOILET SEALS, ODORS
    • LOOSE TOILET REPAIRS
    • LOW WATER USAGE / POWER FLUSH TOILETS
    • TOILET DESIGN CHOICES
    • TOILET CLEARANCE DISTANCES
    • TOILET CLOG REPAIR, UN-BLOCK
    • TOILETS, DON'T FLUSH LIST - home
    • TOILET FLUSH OPERATION
    • TOILET FLUSH HANDLE LEVER REPLACEMENT
    • TOILET INSTALLATION PROCEDURE
    • TOILETS, DON'T FLUSH LIST
    • TOILET FLUSHES POORLY
    • TOILET LEAK CATASTROPHES
    • TOILET OVERFLOW EMERGENCY
    • TOILET PLUGS, SEWER BACKUP
    • TOILET REPLACEMENT PROCEDURE
    • TOILET RUNS CONTINUOUSLY
    • TOILET SEAT / SEAT-LID REPLACEMENT & BOLT SPREADS
    • TOILET TANK / CISTERN LID REPLACEMENTS
    • TOILET TANK SWEATS
    • TOILET WON'T FLUSH
    • WATER DAMAGED BATHROOM FLOOR REPAIR
  • TOILET TYPES, CONTROLS, PARTS - home

Suggested citation for this web page

LOOSE TOILET REPAIRS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Share this article

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to TOILET INFORMATION

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like. You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.

Comment Form is loading comments...

IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING. In any case you are welcome to send an email directly to us at InspectApedia.com at [email protected]

We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.

Citations & References

In addition to any citations in the article above, a full list is available on request.

  • In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggestedCONTINUE READING or RECOMMENDED ARTICLES.
  • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: [email protected]. Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The HOME REFERENCE BOOK - the Encyclopedia of Homes and to use illustrations from The ILLUSTRATED HOME . Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.
ADVERTISEMENT
InspectAPedia.com HOME ABOUT ASK a QUESTION CONTACT CONTENT USE POLICY DESCRIPTION POLICIES PRINT PRIVACY
© 2026 - 1985 Publisher InspectApedia.com - Daniel Friedman

Tag » How To Fix A Wobbly Toilet