Reading And Interpreting A Psychrometric Chart - Sunbird DCIM
Maybe your like
Ready to manage your entire data center in one solution?
Start your test drive here
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
Free 30 Day Trial - With Your Own Data
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
Take DCIM Monitoring for a Test Drive
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
Take DCIM for a Spin
Request Your Free Online Demo Today
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
Free Full Featured Download
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
See why marquee customersare moving to the SunbirdDCIM platform.
Start your test drive here
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
See why marquee customersare moving to the SunbirdDCIM platform.
Start your test drive here
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
DCIM Suite Bundle
See why marquee customers are moving to the Sunbird DCIM platform.
Request your demo here
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
Ready to join marquee customers moving to the Sunbird DCIM platform?
Request your quote here
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
Request Quote
Ready to manage your entire data center in one solution?
Start your test drive here
We’re committed to your privacy. Sunbird uses the information you provide us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.
Menu- Blog
- Videos
- Data Sheets
- eBooks
- Product Screenshots
- Case Studies
- White Papers
- Infographics
- Tools
- Media & Press
- Blog
- Videos
- Data Sheets
- eBooks
- Product Screenshots
- Case Studies
- White Papers
- Infographics
- Tools
- Media & Press
Reading and Interpreting a Psychrometric Chart Psychrometric charts can be pretty tricky to interpret. Just taking a look at it, you may already be confused. With so many lines and axes, you can get lost trying to follow the chart and find out which line represents which axis. So why is it important to know how to read a psychrometric chart? Psychrometric charts allow you to track and monitor the physical and thermodynamic properties of gas-vapor mixtures. To correctly read a psychrometric chart, here is a breakdown and visual representation. Axis Starting at the basics, there are nine different axes, which are categorized one through nine in the graph. Starting at one, they’re labeled as follows, respectively:
- Dry bulb temperature
- Vapor pressure
- Dew point
- Humidity ratio
- Enthalpy
- Saturation temperature
- Wet bulb temperature
- Specific volume of dry air
- Relative humidity
With this one graph, you will be able to configure nine different vital elements. When given any two points on two different axes, all other components of the graph can be found. Dry Bulb Temperature The dry bulb temperature is Point 1 on the graph. This element is measured in degrees Fahrenheit or degrees Celsius, while this specific one is measured in Fahrenheit. Dry bulb temperature is "basically the ambient air temperature." Vapor Pressure Vapor pressure is located at Point 2 on the graph. Vapor pressure is measured in units of mercury. For this specific graph, it is measured in inches of mercury. Dew Point The dew point is represented on the chart by Point 3. The dew point is measured vertically and usually measured in degrees Fahrenheit or degrees Celsius, on this chart it is measured in Fahrenheit. The dew point is the "temperature at which water vapor starts to condense out of the air." Humidity Ratio Point 4 on the graph represents the humidity ratio. The humidity ratio is measured in grains of moisture per pound of dry air. Humidity ratio is expressed by "the ratio between the actual mass of water pressure present in moist air to the mass of the dry air." Enthalpy Enthalpy is Point 5 on the chart. Enthalpy is a quantity that is equal to the total heat content of a system. This is measured in BTU (British thermal unit) per pound of dry air. Saturation Temperature Point 6 on the graph is saturation temperature. The saturation temperature on this graph is measured in degrees Fahrenheit. Saturation temperature is the temperature at which a liquid boils at a fixed pressure. Wet Bulb Temperature The wet bulb temperature is represented on the graph at Point 7. The wet bulb temperature is measured in degrees Fahrenheit. The wet bulb temperature measures "the temperature of the adiabatic saturation." Specific Volume of Dry Air Point 8 is labeled as the specific volume of dry air. On this graph, it is measured in cubic feet per pound of dry air. Specific volume of dry air is the total volume of air with no water vapor per cubic feet per pound. Relative Humidity Relative humidity is labeled by point 9 on the graph. Relative humidity is "the amount of moisture in the air compared to what the air can 'hold' at that temperature." This is represented by a percentage. Reading the Measurements When reading the chart, as long as you have any two elements where the lines cross, you will be able to determine the measure for the rest of the elements. For example, you know that the relative humidity is 30% and the enthalpy is 40 BTU per pound of dry air. The point where these two elements meet is called the "state point." Use the state point as a reference to see where it falls within the other elements of the graph. Since you have the relative humidity and enthalpy measurements, you now can easily find all of the other measurements. Now you want to find the humidity ratio, so you should find the state point. Follow the humidity ratio line all the way to where it intersects the state point and that’s where you can find the measure of humidity ratio, which is 96%. Reading a psychrometric chart isn’t an easy concept to grasp at first. With time and practice the chart will become more familiar and you will be able to learn more and have a better understanding of psychrometric chart relations to improve your data center. Click here to learn more about monitoring the environment of your data center.
Related Links: Data Center Environment Monitoring 101 Why All Data Centers Need Environmental Monitoring 5 Things to Know About Data Center Environmental Monitoring Sunbird's New Patent Will Change the Way You Manage Temperatures in the Data Center How to Safely Avoid Overcooling Your Data Center and Save Money Today Does your Data Center Follow ASHRAE TC 9.9 Thermal Guidelines for Data Processing Environments?- PREVIOUS ARTICLE
- NEXT ARTICLE
Share
Tag » How To Read Psychrometric Chart
-
Read A Psychrometric Chart - Eldridge USA
-
[PDF] How To Read A Psychrometric Chart - Rotronic
-
How To Read A Psychrometric Chart: 11 Steps (with Pictures)
-
How To Read A Psychrometric Chart - YouTube
-
Titus Timeout Podcast - How To Read A Psychrometric Chart
-
How To Read A Psychrometric Chart-stepwise Animated Explanation
-
How To Read A Psychrometric Chart - Engineering Success
-
Psychrometric Chart Use - Penn State Extension
-
Read Psychrometric Chart,Dry,wet Bulb Temperatures,humidity Axes
-
Reading A Psychrometric Chart - Wolfram Demonstrations Project
-
Psychrometric Chart Use | Parameter Generation & Control
-
Psychrometric Chart, How To Read - SlideShare
-
How To Read A Psychrometric Chart & Interpret The Data - Nlyte