ABB CB-2000 USER MANUAL Pdf Download - ManualsLib

× Bookmark added × Added to my manuals
ABB CB-2000 User Manual
  1. Manuals
  2. Brands
  3. ABB Manuals
  4. Measuring Instruments
  5. CB-2000
  6. User manual
ABB CB-2000 User Manual Portable capacitance meter Hide thumbs 1 2 3 4 5 6 7 Table Of Contents 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
  • Contents
  • Table of Contents
  • Bookmarks
Table of Contents
  • Important Safety Information
  • Key to the Symbols
  • Safety Guidelines and Warnings
  • Table of Contents
  • 1 Introduction

    • Introduction
    • Workflow
    • Parts List
  • 2 CB-2000 Software

    • Installation Instructions USB Drivers
    • Installation Via Windows Update (Internet Connection)
    • Installation Via the Drivers on the USB Stick
  • 3 Operating Instructions

    • User Interface
  • 4 CB-2000 User Interface

    • Start-Up Window
    • Main Menu
    • Measurement Menu
    • Clock and Date Adjust Menu
  • 5 PC Application

    • PC Application Upload
    • PC Application Download
    • Measurement Data Opened with Microsoft Excel
  • 6 Maintenance

    • Maintenance
    • Calibration
    • Power Supply
    • Replacement of the Internal Fuse
  • 7 Technical Data

  • 8 Disposal

    • Disposal of Old Electrical and Electronic Equipment
    • Disposing of the Battery
  • 9 Trouble-Shooting

Advertisement

Quick Links

  • 1 Introduction
  • 2 Installation Instructions Usb Drivers
  • 3 Operating Instructions
  • 4 User Interface
  • 5 Start-Up Window
  • 6 Measurement Menu
  • 7 Calibration
  • 8 Technical Data
  • Download this manual
CB-2000 Portable Capacitance Meter User's Guide Table of Contents Previous Page Next Page
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisement

Table of Contents loading

Related Manuals for ABB CB-2000

  • Measuring Instruments ABB ControlMaster CM15 User Manual Measuring Instruments ABB ControlMaster CM15 User Manual Universal process indicator 1/8 din (86 pages)
  • Measuring Instruments ABB Advance Optima magnos206 Operator's Manual Measuring Instruments ABB Advance Optima magnos206 Operator's Manual Ao2000 series gas analyzers (262 pages)
  • Measuring Instruments ABB C1900 series User Manual Measuring Instruments ABB C1900 series User Manual Circular chart recorder and recorder/controller (20 pages)
  • Measuring Instruments ABB C1900 Installation Manual Measuring Instruments ABB C1900 Installation Manual Circular chart recorder and recorder/controller, modbus (rtu) communications option (28 pages)
  • Measuring Instruments ABB C1900 Series Installation Manual Measuring Instruments ABB C1900 Series Installation Manual Circular chart recorder and recorder/controller (20 pages)
  • Measuring Instruments ABB C1900 Installation Manual Measuring Instruments ABB C1900 Installation Manual Circular chart recorder and recorder/controller (16 pages)
  • Measuring Instruments ABB C13 Installation Manual Measuring Instruments ABB C13 Installation Manual Lcd digital power meter (132 pages)
  • Measuring Instruments ABB C13 User Manual Measuring Instruments ABB C13 User Manual (44 pages)
  • Measuring Instruments ABB C1300 Quick Start Manual Measuring Instruments ABB C1300 Quick Start Manual Advanced circular chart recorder (16 pages)
  • Measuring Instruments ABB C11 User Manual Measuring Instruments ABB C11 User Manual (44 pages)
  • Measuring Instruments ABB CM-UFD.M21 Short Manual Measuring Instruments ABB CM-UFD.M21 Short Manual (18 pages)
  • Measuring Instruments ABB CoreSense M10 Installation Manual Measuring Instruments ABB CoreSense M10 Installation Manual Multi-gas monitoring system (96 pages)
  • Measuring Instruments ABB CoreSense M10 User Manual Measuring Instruments ABB CoreSense M10 User Manual Multi-gas monitoring system (108 pages)
  • Measuring Instruments ABB Comem OLI Instruction Manual Measuring Instruments ABB Comem OLI Instruction Manual Liquid level indicator (24 pages)
  • Measuring Instruments ABB COPA-XE Instruction Bulletin Measuring Instruments ABB COPA-XE Instruction Bulletin Electromagnetic flowmeter with pulsed dc magnetic field excitation (64 pages)
  • Measuring Instruments ABB Comem DTI Instruction Manual Measuring Instruments ABB Comem DTI Instruction Manual Temperature monitoring device (28 pages)

Summary of Contents for ABB CB-2000

  • Page 1 CB-2000 Portable Capacitance Meter User’s Guide...
  • Page 2 ABB AB may make improvements and/or changes to this booklet at any time without notice. ABB AB hereby disclaims all liability, warranties and conditions with regard to the information contained in this booklet. No warranty is expressed or implied. ABB AB specifically disclaims the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3: Important Safety Information

    CB-2000 make sure you read its accompanying User’s Guide and warnings carefully. Inappropriate usage of the CB-2000 can cause heat generation, explosion, fire, bodily injury, or death. If you do not fully understand our CB-2000 User’s Guide or warnings, please direct your response to ABB AB.
  • Page 4: Safety Guidelines And Warnings

    - The CB-2000 shall only be used by qualified and properly trained personnel, with the level of competence required for work in connection with high voltage capacitor banks and/or harmonic filters.
  • Page 5 Avoid skin contact in event of leakage of impregnation fluid. Refer to the capacitor safety instructions. In case of skin contact, wash off immediately with soap and water. Consult a doctor if skin irritation persists. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 5...
  • Page 6 Prolonged exposure to heat may cause the battery to produce hazardous metal fumes of nickel, cobalt, aluminum and manganese, as well as hydrogen gas, caustic vapors of potas- sium and sodium hydroxide and other toxic by-products. 6 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 7 Note to physician The acutely toxic ingredients are concentrated (35%) potassium and sodium hydroxides and nickel. Anticipated potential leakage of potassium and sodium hydroxides is 1-2 grams. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 7...
  • Page 8: Table Of Contents

    6. Maintenance Maintenance Calibration Power supply Replacement of the internal fuse 7. Technical data 8. Disposal Disposal of old electrical and electronic equipment Disposing of the battery 9. Trouble-shooting 8 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 9 Section 1 Introduction ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 9...
  • Page 10: Introduction

    The handling and operation of the CB-2000 is quick and easy: Prepare the CB-2000 for a measurement session by uploading the last session data or routine test data (optional). After all safety measures have been taken on the capacitor bank, connect the voltage supply and clip-on trans- former and perform a measurement.
  • Page 11: Parts List

    1HSD100909-725 1HSD100909-726 1HSD100909-729 Voltage clips 4-pin extension cable Rechargeable NiMH for voltage clips battery pack 1HSD100909-727 1HSD100909-728 1HSD100909-730 Clip-on transformer 3-pin extension cable Battery holder for clip-on transformer ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 11...
  • Page 12 (AUS, EU, JP, KOR, UK, US) 1HSD100909-732 1HSD100909-733 User´s Guide Product casing Parts list - miscellaneous Set of spare fuses 1HSD101225-140 Calibration of CB-2000 1HSD100909-734 CB-2000 system with casing 1HSD100909-724 12 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 13: Cb-2000 Software

    Section 2 CB-2000 software ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 13...
  • Page 14: Installation Instructions Usb Drivers

    2.2 Installing via Windows Update (Internet connection) Connect the CB-2000 to a spare USB port on your PC. The Found New Hardware Wizard will launch. NOTE: If you are running Windows XP or Windows XP SP1, temporarily disconnect your PC from the Internet.
  • Page 15 If no Internet connection is available, continue with Section 2.3 below. Select “Install the software automatically (Recommended)” in the next window and click the “Next” button. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 15...
  • Page 16 The following window appears while Windows is searching for the drivers in the Windows Update data- base. This can take a few minutes. When the wizard has found and installed the CB-2000 drivers, the window below is displayed. Click “Finish” to complete the installation.
  • Page 17: Installation Via The Drivers On The Usb Stick

    “Next” to proceed with the installation. If there is an available Internet connection, Windows XP will silently connect to the Windows Update website and install the latest available driver. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 17...
  • Page 18 “Browse” button. Once the file path has been entered in the box, click “Next” to proceed. 18 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 19 2. CB-2000 software The screen shown in the figure below will be displayed as Windows XP copies the required driver files. Click “Finish” to complete the installation. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 19...
  • Page 21: Operating Instructions

    Section 3 Operating instructions ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 21...
  • Page 22 CB-2000. WARNING! The CB-2000 shall only be used by qualified and properly trained personnel, with the level of competence required for work in connection with high voltage capacitor banks and/or harmonic filters.
  • Page 23 Short-circuit the two bushings of the capacitor unit/parallel group to be measured. Remove the temporary short-circuit. Connect the voltage clips cable to the CB-2000 and connect the voltage clips to the capacitor unit or the parallel group of units to be measured.
  • Page 24: User Interface

    Section 4 User interface...
  • Page 25 2 seconds to turn off. Erase button CB-2000 The LCD backlight is automatically switched off after five minutes of inactivity; after 30 minutes the system is shut down. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 25...
  • Page 26: Start-Up Window

    4. User interface 4.2 Start-up window When the CB-2000 is switched on, a start-up window appears for 5 seconds before the CB-2000 enters the Main menu. ABB CAPACITOR CB-2000 Version 1.00 Battery Temperature +28°C 1. Version of software. 2. Battery status in percent or “External power” if external power supply is used.
  • Page 27: Measurement Menu

    Measurement menu for the specific capacitor. A maximum of 1000 capacitor units can be stored in the CB-2000. An “OUT OF MEMORY” message is displayed if further capacitor units are added. If this occurs, download measurements to a PC for safe keeping and/or erase outdated measurements.
  • Page 28: Clock And Date Adjust Menu

    Use the arrow keys to move the cur- sor. To save a new date and time and return to main menu press 28 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 29: Pc Application

    Section 5 PC application ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 29...
  • Page 30: Pc Application Upload

    5. PC application 5.1 PC application upload The CB-2000 can be prepared for a measurement session by uploading the most recent session data or routine test data. Connect the CB-2000 to a PC and switch it on. Routine test or session data can be accessed from the Open command on the File menu.
  • Page 31 Data is uploaded with the “Upload” command on the CB-2000 menu. Before the upload begins the user is given the opportunity to synchronize the CB-2000 clock with the PC. If “Yes” the clock is set according to the PC’s system time.
  • Page 32: Pc Application Download

    Connect the CB-2000 to a PC and switch it on. Data is downloaded with the “Download” command on the CB-2000 menu. During download, a progress bar is shown. 32 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 33 5. PC application Measurement data is saved with the “Save As” command on the File menu. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 33...
  • Page 34: Measurement Data Opened With Microsoft Excel

    Temperature of latest measurement Digits only The same file can be uploaded to a CB-2000 unit, with the serial no. column and reference column being especially important. The reference column can contain values from the routine test or the latest measure- ment.
  • Page 35 Section 6 Maintenance ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 35...
  • Page 36: Maintenance

    Any clip-on transformer other than the one specified on the back of the CB-2000 should NOT be used. Usage with a non-specified clip-on trans- former may result in inaccurate measurement readings. 36 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 37: Power Supply

    6. Maintenance 6.3 Power supply The CB-2000 can be powered with the accompanied power adapter, which can be connected to a 100 to 240 V 50/60Hz AC power supply. The CB-2000 unit is delivered with a pre-installed rechargeable battery pack, which can be re- placed with the included battery holder.
  • Page 38: Replacement Of The Internal Fuse

    The rechargeable battery pack can be replaced by the included battery holder as per below: Disconnect and turn off the CB-2000. Loosen the 4 screws that secure the battery cover on the back of the CB-2000. Open the battery cover.
  • Page 39: Technical Data

    Section 7 Technical data ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 39...
  • Page 40 Power adapter output 24 VDC, 1.25 A Battery pack charging time 3 hours with fully discharged batteries Test voltage output, fuse protection 3 A, 250 V fast fuse 40 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 41: Disposal

    Section 8 Disposal ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 41...
  • Page 42: Disposal Of Old Electrical And Electronic Equipment

    This helps prevent potential negative conse- quences for the environment and human health. Check local regulations. 8.2 Disposing of the battery Check local regulations. Never use municipal waste. 42 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 43: Trouble-Shooting

    Section 9 Trouble-shooting ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 43...
  • Page 44 9. Trouble-shooting Refer to the troubleshooting tables when the CB-2000 does not function properly. If the problem expe- rienced is not listed or if the instructions below do not help, disconnect the CB-2000 and contact your sales support representative. 44 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 45 “Upload is limited to 1000 rows, A maximum of 1000 capacitor Reduce the number of upload is cancelled” units can be stored in the rows to 1000 or less. CB-2000. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 45...
  • Page 46 Defective cable to voltage Send the CB-2000 clips. in for service. Wrong current transformer. Check whether the serial num- bers of the current transformer and the CB-2000 match. 46 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors...
  • Page 47 The battery status is shown value. for the rechargeable battery pack. If batteries in the battery holder are used, the algorithm might not be able to accurately calculate the remaining battery power. ABB Power Capacitors | Portable Capacitance Meter CB-2000 — User´s Guide 47...

Table of Contents

Save PDF

Print

Print page 1 Print document (47 pages)

Rename the bookmark

Cancel

Delete bookmark?

Cancel Delete

Delete from my manuals?

Cancel Delete

Login

Sign In OR Sign in with Facebook Sign in with Google Don't have an account? Sign up! Restore password

Upload manual

Upload from disk Upload from URL Thank you for your help!

Từ khóa » Cb 2000