Ammonia Detector | E2608-NH3-E | Evikon MCI OÜ
- Company
- Competences
- Gas Detection
- Temperature Measurement
- Humidity & Moisture Measurement
- Pressure Measurement
- Level Measurement
- Monitoring & Control
- Products
- Sensors & Transmitters
- Meters & Controllers
- Accessories
- Markets
- Cooling and Refrigeration
- HVAC
- Food and Beverage Industry
- Agriculture
- Process Industries
- How to buy
- Our distributors
- Become a distributor
- FAQ
- Knowledge base
- Home
- Competences
- Gas Detection
- Ammonia
- E2608-NH3-E
E2608-NH3-E
Ammonia Detector
Competences
- Gas Detection
- Ammonia
- Acetylene
- Butane
- Carbon Dioxide
- Carbon Monoxide
- Chlorine
- Ethanol
- Ethylene
- Ethylene Oxide
- Halocarbons
- Hexane
- Hydrogen
- Hydrogen Sulfide
- Methane
- Nitric Oxide
- Nitrogen Dioxide
- Nitrous Oxide
- Octane
- Oxygen
- Ozone
- Propane
- Sulfur Dioxide
- Sulfur Hexafluoride
- Volatile Organic Compound
- Temperature Measurement
- Humidity & Moisture Measurement
- Pressure Measurement
- Level Measurement
- Monitoring & Control
Features
- Stable long-life electrochemical sensor
- Range 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3
- Resolution 1 ppm NH3
- Two SPST relays
- 2 × 4-20 mA or 0-10 V, RS485
Description
Ammonia detector-transmitter E2608-NH3-E is a member of new PluraSens® family of multifunctional measurement instruments.
The instrument is intended for leakage control in refrigeration facilities, warehouses etc. It is not recommended to use the device in spaces with constantly high ammonia concentration such as cattle, pig and poultry livestock houses, since it shortens the sensor lifetime.
The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.
Two relays with closing contact may be used for remote signalling or concentration control. Two alarm set-points are user settable.
Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.
Technical Data
| Calibration | ammonia NH3 |
| Sensor type | electrochemical |
| Sampling method | diffusion |
| Detection range | 0...100 ppm NH3 |
| 0...300 ppm NH3 | |
| 0...1000 ppm NH3 | |
| 0...5 000 ppm NH3 | |
| up to 10000 ppm on request | |
| Resolution | 1 ppm NH3 |
| Sensor lifetime | > 2 years |
| Power supply | 12...36 VDC (default), |
| 24 VAC or 230 VAC as options | |
| Digital interface | RS485, Modbus RTU protocol |
| Analog outputs | 2 × 4-20 mA / 0-10 V, user settable |
| Output relays | 2 × SPST relays (closing contact), |
| 250 VAC / 30 VDC, 5 A max | |
| Default alarm set-points | 25 ppm / 35 ppm NH3 |
| Enclosure | grey ABS plastic, wall mount, IP65 |
| Dimensions | H85 × W82 × D55 mm |
| Operating conditions | -40...+50°C, -30...+50°C (for 0...5 000 ppm), |
| 15...90 %RH |
Documents
TechnicalDatasheet UserManual CEDeclaration Similar Products
E2618-NH3-E - Ammonia Transmitter
- Stable long-life electrochemical sensor
- Range 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3
- Resolution 1 ppm NH3
- 2 × 4-20 mA or 0-10 V, RS485
E2638-NH3-E - Ammonia Detector
- Stable long-life electrochemical sensor
- Range 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3
- Resolution 1 ppm NH3
- Two SPST relays option
- 2 × 4-20 mA or 0-10 V, RS485
E2648-NH3-E - Ammonia Detector
- Stable long-life electrochemical sensor
- Range 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3
- Resolution 1 ppm NH3
- Two SPST relays option
- 2 × 4-20 mA or 0-10 V, RS485
E2608-NH3-P - Ammonia Detector
- Stable long-life pellistor gas sensor
- Range 0...15% vol. (0…100% LEL)
- Resolution 0.1% vol. or 1% LEL
- Two SPST relays
- 2 × 4-20 mA or 0-10 V, RS485
- Wall-mount or duct-mount version
- Attached or remote sensor
E2618-NH3-P - Ammonia Detector
- Stable long-life pellistor gas sensor
- Range 0...15% vol. (0…100% LEL)
- Resolution 0.1% vol. or 1% LEL
- Wall mount or duct mount version
- Attached or remote sensor
- 2 × 4-20 mA or 0-10 V, RS485
E2638-NH3-P - Ammonia Detector
- Stable long-life pellistor sensor
- Range 0...15% vol. (0…100% LEL)
- Resolution 0.1% vol. or 1% LEL
- Two SPST relays option
- 2 × 4-20 mA or 0-10 V, RS485
- Attached or remote sensor
- LCD indicator option
- Easy to install IP65 enclosure
E2648-NH3-P - Ammonia Detector
- Stable long-life pellistor sensor
- Range 0...15% vol. (0…100% LEL)
- Resolution 0.1% vol. or 1% LEL
- Two SPST relays option
- 2 × 4-20 mA or 0-10 V, RS485
- Attached or remote sensor
- Industrial IP66 wall mount housing
E2670-NH3-E - Flameproof Ammonia Detector
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3
- Resolution 1 ppm NH3
- Two SPST relays option
- 2 × 4-20 mA or 0-10 V, RS485
E2670-NH3-P - Flameproof Ammonia Detector
- Suitable for ATEX Zones 2 and 22
- Stable long-life pellistor (catalytic bead) sensor
- Range 0...15% vol. (0…100% LEL)
- Resolution 0.1% vol. or 1% LEL
- Two SPST relays option
- 2 × 4-20 mA or 0-10 V, RS485
- Wall mount flameproof metal enclosure
E2639-NH3 - Ammonia Detector
- Stable long-life electrochemical sensor
- Ranges 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3
- Resolution 1 ppm NH3
- Three SPDT relays
- 2 × 4-20 mA, RS485
- Remote probe option
Từ khóa » é Nh3
-
Ammonia | NH3 - PubChem
-
Ammonia - Wikipedia
-
AMMONIA (NH3) E - Polymed Lab
-
MIDAS-E-NH3 | Honeywell Analytics | Gas & Specialty Sensors - Kele
-
Search For MIDAS-E-NH3 - Instrumart
-
Is Ammonia The Fuel Of The Future? - C&EN
-
One-Pot Multienzymatic Transformation Of NH3, CO2, And Ornithine ...
-
Homogeneous Electrocatalytic Oxidation Of Ammonia To N2 ... - PNAS
-
[PDF] 4500-nh3 Nitrogen (ammonia) - Edge Analytical
-
Ammonia - MAN Energy Solutions
-
Honeywell Analytics MIDAS-E-NH3 Sensor Cartridge - E
-
E-Sense Ammonia (NH3) Electrochemical Gas Detector 0-150ppm
-
Ammonia Energy Association