Biomechanics Of Vertebral Artery Segments C1-C6 During Cervical ...
Objective: The purpose of this study was to measure strains in the human vertebral artery (VA) within the cervical transverse foramina and report the first results on the mechanical loading of segments of the VA during spinal manipulation of the cervical spine.
Methods: Eight piezoelectric ultrasound crystals of 0.5-mm diameter were sutured into the lumen of the left and right VA of one cadaver. Four hundred-nanosecond ultrasound pulses were sent between the crystals to measure the instantaneous lengths of the VA segments (total segments n = 14) at a frequency of 200 Hz. Vertebral artery engineering strains were then calculated from the instantaneous lengths during cervical spinal range of motion testing, chiropractic cervical spinal manipulation adjustments, and vertebrobasilar insufficiency testing.
Results: The results of this study suggest complex and nonintuitive strain patterns of the VA within the cervical transverse foramina. Consistent (for 2 chiropractors) and repeatable (for 3 repeat measurements for each chiropractor) elongation and shortening of adjacent VA segments were observed simultaneously and could not be explained with a simple model of neck movement. We hypothesized that they were caused by variations in the location and stiffness of the VA fascial attachments to the vertebral foramina and by coupled movements of the cervical vertebrae. However, in agreement with previous work on VA strains proximal and distal to the cervical transverse foramina, strains for cervical spinal manipulations were consistently lower than those obtained for cervical rotation.
Conclusions: Although general conclusions should not be drawn from these preliminary results, the findings of this study suggest that textbook mechanics of the VA may not hold, that VA strains may not be predictable from neck movements alone, and that fascial connections within the transverse foramina and coupled vertebra movements may play a crucial role in VA mechanics during neck manipulation. Furthermore, the engineering strains during cervical spinal manipulations were lower than those obtained during range of motion testing, suggesting that neck manipulations impart stretches on the VA that are well within the normal physiologic range of neck motion.
Từ khóa » C1 C6
-
C1 Objectives Of Clauses C2 To C6 | Building Performance
-
The C1-C6 Spectrum After Fifteen Years - Missio Nexus
-
The C1 To C6 Spectrum - Frontline Missions
-
What Is C1 - C6? Differences Explained - YouTube
-
Chemical Structures Of Compounds C1-C6. - ResearchGate
-
Revisiting The C1-C6 Spectrum In Muslim Contextualization
-
Alkylamines (C1-C6) - Chemical Economics Handbook - IHS Markit
-
Cervical Vertebrae - Spine-health
-
Cervical Spine (Neck): What It Is, Anatomy & Disorders
-
Effects Of Primary C1–C6 Linear Alcohol Addition And ... - IOPscience
-
Effect Of Fenton Pretreatment On C1 And C6 Oxidation Of Cellulose ...
-
Molecular Siting Of C1–C6 N-Alkanes In ZIF-4: A Hybrid Monte Carlo ...