C2K | Ex Eb, Ex Ta | Explosive Atmosphere Cable Gland

Search

Search the full site including products, accessories, news posts & pages.

All Products News Pages

Product Finder

Our Product Finder tool allows you to find the perfect product for your requirements.

Product TypeCable Gland (106)Cable Cleats (12) Code of InstallationIEC Unclassified (45)CEC Unclassified (3)IEC Zones (49)CEC Class Zones (26)CEC Class Divisions (20)NEC Class Zones (19)NEC Class Divisions (19)IEC Mining (Group I) (14)NEC Unclassified (3)Norsok Zones (11)AS/NZS Mining (Group I) (15)AS/NZS Zones (48)Single Cable (8)Parallel Formation (8)Trefoil Formation (7)GOST Zones (36) Form of ProtectionIndustrial (45)Ordinary Locations (6)Wet Locations (6)Ex d IIC Gb (36)Ex e IIC Gb (46)Ex nR IIC Gc (34)Ex ta IIIC Da (43)Class I, Zone 1 (19)Class I, Zone 2 (19)Class I, Div 2 (18)Class I, Div 2, Groups ABCD (17)Class II, Div 2 (18)Class II, Div 2, Groups EFG (18)Class III, Div 1 (15)Class I, Zone 1, AEx e IIC Gb (19)Class III, Div 2 (13)Class I, Zone 20 (10)Class I, Zone 21 (10)Class I, Zone 22 (10)Class I, Zone 1, AEx d IIC Gb (10)Class I, Zone 2, AEx d IIC Gb (10)Class I, Zone 2, AEx e IIC Gb (12)Class I, Zone 2, AEx nR IIC Gc (8)Class I, Zone 20, AEx ta IIIC Da (10)Class I, Div 1 (8)Class II, Div 1 (10)Class I, Groups ABCD (6)Class I, Div 1, Groups ABCD (8)Class II, Div 1, Groups EFG (10)Ex d I Mb (20)Ex e I Mb (20)Class I, Groups BCD (2)Ex tD A21 IP66 (2)Ex tb IIIC Db (43)Class I, Zone 21, AEx tb IIIC Db (10)Ex tc IIIC Dc (43)Class I, Zone 22, AEx tc IIIC Dc (10)Ex nRc IIC Gc (1)Ex eb IIC Gb (3)Ex db IIC Gb (1)Ex eb I Mb (1)Ex db I Mb (1)Two Bolt (10)Single Bolt (10)1Ex e IIC Gb X (36)1Ex d IIC Gb X (27)2Ex nR IIC Gc X (27)Ex ta IIIC Da X (35)Ex tb IIIC Db X (35)Ex tc IIIC Dc X (35) Cable TypeSingle Wire Armour (SWA) (38)Aluminium Wire Armour (AWA) (34)Aluminium Strip Armour (ASA) (25)Pliable Wire Armour (PWA) (27)Screened Flexible (EMC) Wire Braid (e.g. CY / SY) (42)Steel Tape Armour (STA) (24)Aluminium Tape Armour (e.g. ATA) (24)Wire Braid Armour (42)Armoured & Jacketed (24)Braid Armoured Shipboard Cable (24)Marine Shipboard Braid Armoured Cable (24)Unarmoured (27)Marine Shipboard Non-armoured Cable (19)Lead Sheathed, Unarmoured Cable (2)Lead Sheathed & Aluminium Wire Armour (LC/AWA) (9)Lead Sheathed & Pliable Wire Armour (LC/PWA) (8)Lead Sheathed & Single Wire Armour (LC/SWA) (9)Lead Sheathed & Steel Tape Armour (LC/STA) (8)Lead Sheathed & Strip Armour (LC/ASA) (8)Lead Sheathed & Wire Braid Armour (8)Screened & Single Wire Armour (SWA) (4)Screened & Aluminium Wire Armour (AWA) (4)Marine Shipboard Cable (11)Tray Cable (9)Flexible Cord (5)Extra Hard Usage Cord (2)Flat Form Unarmoured Cable (2)Corrugated & Interlocked Metal Clad Armour (MC) - Steel (4)Corrugated & Interlocked Metal Clad Armour (MC) - Aluminum (4)Continuously Welded Corrugated Metal Clad Armour (MC-HL) - Aluminum (4)Continuously Welded Corrugated Metal Clad Armour (MC-HL) - Steel (4)TECK (4)TECK 90 (4)TECK 90-HL (4)M10 (12)M12 (8) Sealing ConfigurationNo Seal (4)Outer Seal (46)Outer Seal / Conduit Connection (3)Double Outer Seal (3)Inner & Outer Seal (28)Inner Barrier Seal & Outer Seal (18)Inner Barrier Seal & Conduit Connection (2)Inner Barrier Seal & Outer Seal / FRAS Hose Connection (1)Outer Seal / FRAS Hose Connection (1)Very Heavy (12) ApprovalsBS 6121 (45)CSA (11)ATEX (61)c-CSA-us (19)UL (9)IECEX (61)KCC (27)NEPSI (34)CCO-PESO (44)TR-CU-EAC (38)INMETRO (30)RETIE (35)GOST-K (74)IEC 62444 (45)GOST-R (44)ABS (67)Lloyds (70)BV (40)DNV-GL (41)Nylon (2)LSF (2)LUL Approved Polymer (2)Aluminium (3)Epoxy Coated Aluminium (2)Stainless Steel (6)Aluminium / Stainless Steel (1) Deluge ProtectionNo (68)Yes (41)Lateral Load (12)Axial Load (12)Short Circuit Forces (8)
  • Home
  • Cable Glands
    • Products
      • Industrial / General Purpose
      • Explosive Atmosphere
      • Group I Mining
      • American NEC & CEC
      • Accessories
      • View all Cable Glands & Cleats by Names
      • How To Order
      • How to Order TruSeal
    • Technical
      • Americas specific NEC and CEC
      • Cable Gland Sizes
      • Catalogue Downloads
      • Certificate Downloads
      • Certification Schemes
      • Explosive Atmospheres
      • Product Downloads
      • What is a Cable Gland?
      • TruSeal Materials
      • STEP File Downloads
    • Installation
      • Tools and Guides
      • Training and Support
      • Installation Downloads
  • Cable Cleats
    • Products
      • Metal
      • Polymeric
      • Single / Multicore Application
      • Trefoil Application
      • Quad Application
      • Accessories
      • View All
    • Technical
      • Certificate Downloads
      • Cable Cleat Accessories
      • Cable Cleat Nut Spacer
      • Cable Cleat Selection
      • Cable Formations
      • Recommended Cleat Spacings
      • Catalogue Downloads
      • Cleat Fixing Packs
      • Fire Performance
      • Galvanic Corrosion
      • Good Installation Practices
      • How To Order
      • Intermediate Restraints
      • Materials
      • Product Downloads
      • Product Overview
      • Resistance Classifications
      • Twin arc profiles
      • What is a Cable Cleat?
      • What is a Short Circuit?
      • Why use a Cable Cleat?
    • Installation
      • Installation Instructions
    • Cleat Selector
  • Thread Conversions & Accessories
    • Stopper Plugs
    • Cable Gland Adaptors / Reducers
    • Breather / Drain Plugs
    • Unions & Barrier Unions
    • How To Order Accessories
    • Cable Gland Accessories
    • Cable Cleat Accessories
  • Accessories
    • 717e | Nylon Universal Stopper Plug | Ex e | Conduit Accessory
    • TruSeal Accessories
    • 717 | Nylon Universal | Industrial Stopper Plug
    • LSF & PVC Cable Shrouds
    • 737 | Thread Conversions | Adaptors & Reducers
    • 787 | 90 Degree Adaptor
    • 797 | Male to Male or Female to Female Adaptor
    • 777 | Insulated Adaptor
    • 781 | Breather / Drain Plug
    • 783 | Dual Entry Y Adaptor
    • 747 | Recessed Stopper Plug
    • 757 | Hexagon Head Stopper Plug
    • 767 | Dome Stopper Plug
    • 780 | In-Line Union
    • PX780REX | RapidEx Barrier Union
    • 784 | 45 Degree Union
    • PX784REX | 45 Degree RapidEx Barrier Union
    • 789 | 90 Degree Union
    • PX789 | 90 Degree Barrier Union
    • PX789REX | 90 Degree RapidEx Barrier Union
    • Ingress Discs
    • Armour Former Tool
    • Outer Seal Tightening Guides
    • Sentinel, Cable Gland Corrosion Shield
    • Cable Gland Accessories
    • Cable Cleat Accessories
  • Our Markets
  • CMP World
    • CMP at a glance
    • Net Zero Policy
    • Inside CMP
    • Net Zero Policy
    • Setting Standards
      • Health and Safety
      • Quality
      • Environment
    • Net Zero Policy
    • Recruitment
      • Careers with CMP
      • Graduates
      • Apprentices
      • Vacancies
    • Net Zero Policy
    • Accreditations
      • IMechE
    • Net Zero Policy
    • Terms and Conditions of Sale
    • Net Zero Policy
    • Terms and Conditions of Purchase
    • Net Zero Policy
    • Compliance
    • Net Zero Policy
  • News
    • Latest News
    • CMP Events
  • Contact
    • Contact Us
    • Our Offices
    • Distributors
  • Cleat Selector
EN-GB | EN-US | RU | CN

C2K | Ex eb, Ex ta | Explosive Atmosphere Cable Gland

If you would like further information regarding this product, please complete the form below.

  • Home
  • Cable Glands
  • Products
  • Explosive Atmosphere
  • C2K | Ex eb, Ex ta | Explosive Atmosphere Cable Gland
Want to discuss this product with one of the CMP Technical Team? Call one of our team now on +44 191 265 7411
  • Ex nR
  • Ex ta
C2K | Ex eb, Ex ta | Explosive Atmosphere Cable Gland For all types of Armoured cables Enquire about this product Download/Print Data Sheet Installation Instructions View/Download Step Files

We'd like to keep in touch

We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.

No thanks, I'd just like to Download the datasheet.

Close Description Technical

Internationally Approved, Ex e, Explosive Atmosphere Cable Gland

• Metal-to-metal armour clamping • Direct & remote installation • Integral protected deluge seal • Controlled outer ‘load retention’ seal • Unique OSTG prevents overtightening • Integral protected deluge seal • -60°C to +130°C • Class I Zone 1, 21 and Zone 2 • Internationally marked, IECEx & ATEX • Superior EMC performance

For under / oversized armour wires click here

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications * Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1323X, CML 18ATEX4315X
UKEX Certificate CML 21UKEX1251X
Code of Protection II 2G, II 1D, Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc
Compliance Standards EN 60079-0,7,31
IECEx Certificate IECEx CML 18.0180X
Code of Protection Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc
Compliance Standards IEC 60079-0,7,31
EAC Certificate C-GB.A07.B.04594/22
CCOE / PESO (India) Certificate Ex nR: P548695, Ex e: P533772
CCC Certificate 2020322313003285
INMETRO Approval TÜV 12.0617X
RETIE Approval EL-CS-220061
UkrSEPRO CU 19.0371X
SANS IA S-XPL21804 21.0009X
Marine Approvals LRS: LR22320739TA, DNV: TAE00000Y, ABS: 21-2090433-PDA, BV: 43180
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Wire Braid Armour (e.g. SWB), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Armoured & Jacketed
Armour Clamping Reversible Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Sealing Area(s) Cable Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners, Armour Former Tool
ECAS Certificate E23-02-065457

Note: * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444 ** When CMP installation accessories are used. Refer to Maintaining a Seal for further information. *** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request

Jump to technical illustration

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Showing: Imperial Metric
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Cable Bedding Diameter 'A'Overall Cable Diameter 'B'Armour RangeAcross Flats 'D'Across Corners 'D'Protrusion Length 'F'Combined Ordering Reference (*Brass Metric)ShroudCable Gland Weight (Kgs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length (NPT) 'E'NPTMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering Suffix
20S16M200.59½'0.78¾"0.340.240.520.010.040.030.051.201.322.5620S16C2K1RAPVC048.11
20SM200.59½'0.78¾"0.460.370.630.010.040.030.051.201.322.4420SC2K1RAPVC048.47
20M200.59½'0.78¾"0.550.490.820.020.040.030.051.201.322.4820C2K1RAPVC067.76
25SM250.59¾'0.801"0.790.550.870.020.050.050.061.481.632.7425SC2K1RAPVC0912.35
25M250.59¾'0.801"0.790.721.030.020.050.050.061.481.632.7425C2K1RAPVC0912.35
32M320.591'0.981 ¼"1.020.931.330.020.050.060.081.811.992.9532C2K1RAPVC1119.40
40M400.591 ¼'1.011 ½"1.271.101.590.020.060.060.082.172.382.9540C2K1RAPVC1526.46
50SM500.591 ½'1.032"1.501.391.840.020.060.080.102.362.603.0350SC2K1RAPVC1830.34
50M500.592'1.062 ½"1.741.592.090.020.060.080.102.763.043.0350C2K1RAPVC2139.86
63SM630.592'1.062 ½"1.971.802.340.020.060.080.102.953.253.1563SC2K1RAPVC2347.62
63M630.592 ½'1.573"2.202.152.590.020.060.080.103.153.463.1563C2K1RAPVC2547.27
75SM750.592 ½'1.573"2.442.322.830.020.060.080.103.543.903.4375SC2K1RAPVC2871.25
75M750.593'1.633 ½"2.532.633.090.020.060.100.123.944.333.4675C2K1RAPVC3087.48
90M900.943 ½'1.694"3.093.003.560.030.060.120.164.534.984.0290C2K1RAPVC32124.16
100M1000.943 ½'1.694"3.583.393.990.030.060.120.165.005.504.49100C2K1RALSF33161.55
115M1150.944"1.735"3.864.004.340.030.060.120.165.255.784.49115C2K1RALSF34229.28
130M1300.945"1.84-4.534.344.850.030.060.120.166.006.604.49130C2K1RALSF35299.83
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Cable Bedding Diameter 'A'Overall Cable Diameter 'B'Armour RangeAcross Flats 'D'Across Corners 'D'Protrusion Length 'F'Combined Ordering Reference (*Brass Metric)ShroudCable Gland Weight (Kgs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length (NPT) 'E'NPTMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering Suffix
20S16M2015.0½'19.9¾"8.76.113.10.31.00.81.2530.533.665.020S16C2K1RAPVC040.23
20SM2015.0½'19.9¾"11.79.515.90.31.00.81.2530.533.662.020SC2K1RAPVC040.24
20M2015.0½'19.9¾"14.012.520.90.41.00.81.2530.533.663.020C2K1RAPVC060.22
25SM2515.0¾'20.21"20.014.022.00.41.21.251.637.541.369.525SC2K1RAPVC090.35
25M2515.0¾'20.21"20.018.226.20.41.21.251.637.541.369.525C2K1RAPVC090.35
32M3215.01'25.01 ¼"26.023.733.90.41.21.62.046.050.675.032C2K1RAPVC110.55
40M4015.01 ¼'25.61 ½"32.227.940.40.41.61.62.055.060.575.040C2K1RAPVC150.75
50SM5015.01 ½'26.12"38.235.246.70.41.62.02.560.066.077.050SC2K1RAPVC180.86
50M5015.02'26.92 ½"44.140.453.00.61.62.02.570.177.177.050C2K1RAPVC211.13
63SM6315.02'26.92 ½"50.045.659.40.61.62.02.575.082.580.063SC2K1RAPVC231.35
63M6315.02 ½'39.93"56.054.665.80.61.62.02.580.088.080.063C2K1RAPVC251.34
75SM7515.02 ½'39.93"62.059.072.00.61.62.02.590.099.087.075SC2K1RAPVC282.02
75M7515.03'41.53 ½"64.266.778.40.61.62.53.0100.0110.088.075C2K1RAPVC302.48
90M9024.03 ½'42.84"78.676.290.30.81.63.154.0115.0126.5102.090C2K1RAPVC323.52
100M10024.03 ½'42.84"91.086.1101.40.81.63.154.0127.0139.7114.0100C2K1RALSF334.58
115M11524.04"44.05"98.0101.5110.20.81.63.154.0133.4146.7114.0115C2K1RALSF346.50
130M13024.05"46.8-115.0110.2123.20.81.63.154.0152.4167.6114.0130C2K1RALSF358.50
Dimensions displayed in millimeters unless otherwise stated

Technical Illustration

Knowledge Base

Get expert industry insights on this product

Read More Additional Information Close icon-cross

Combating Galvanic Corrosion at CMP

The type and thickness of nickel coatings applied to brass cable glands varies significantly around the world, and many of the solutions adopted are inherently porous, meaning that they are unable to provide complete protection against chemical attack, corrosion, or material break-down. There are typically two types of nickel plating in common use, these being electro nickel plating and electro-less nickel plating.

Read more

Common Cable Gland Types Designed to IEC Standards

Under IEC standards, three main types of cable glands exist for braided, armoured and non-armoured cable intended for use in explosive atmosphere applications.

Read more

Dust Ignition Prevention

Combustible dust can be ignited by electrical equipment in several ways, for example by: - Surfaces of the equipment that are above the minimum ignition temperature of the dust concerned. - The temperature at which a type of dust ignites is a function of the properties of the dust;

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now
  • Gender Pay Report
  • Terms and Conditions
  • Disclaimer
  • Internet Copyright Notice
  • Cookie Policy
  • Privacy Policy
  • Anti-Slavery and Human Trafficking Policy
  • Anti Corruption and Bribery Policy
  • Terms and Conditions of Sale
  • Terms and Conditions of Purchase
  • Registered office

  • CMP Products Ltd: 11 Glasshouse Street, St Peters, Newcastle upon Tyne, NE6 1BS(No. 06143400)
  • Copyright © CMP Products Limited 2025

Từ khóa » C2k