Skip to main EUCHNER – More than safety. HomeProductsTransponder-coded safety switches without guard lockingCES-AR safety switchCES-AR-C01-CH-SA CES-AR-C01-CH-SA (Order no. 098942) Choose content Description Choose content Technical data Components Accessories Choose content Ordering data Download as PDF

Safety switch CES-AR-C01-..., RFID, plug connector(s) M12

  • Multicode
  • Monitoring output door position OUT
  • Plug connector M12, 8-pin
CES-AR-C01-CH-SA (Order no. 098942) Description Technical data Accessories Downloads CAD/eCAD Ordering data

Description

Approach direction and installation position

1 active face, adjustable in 5 directions

Multicode evaluation

The system checks whether the actuator type is one that can be recognized by the system (multicode evaluation). The system has a low coding level. Every suitable actuator is recognized by the switch.

Safety characteristics

Thanks to two redundant safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:

  • Category 4 /PL e according to EN 13849-1
  • SIL 3 according to EN IEC 62061 Table 4

The OSSD outputs used check their function for short circuits and short circuits with test pulses.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Typical actuating ranges

With actuators CES-A-BBA and CES-A-BCA

pWith actuators CES-A-BBA and CES-A-BCA/p

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.

With actuator CES-A-BPA

pWith actuator CES-A-BPA/p

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Attention:

The actuating range may vary depending on the actuator, substrate material and installation situation. Further actuating ranges can be found in the operating instructions.

Plug connector(s) adjusted C01

Plug connector(s) adjustable in 6 orientations.

Terminal assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring
1IBEnable input, channel BWH
2UBElectronics operating voltage, 24 V DCBN
3OASafety output, channel AGN
4OBSafety output, channel BYE
5OUTMonitoring outputGY
6IAEnable input for channel APK
70 VWeight 0 V DCBU
8RSTReset inputRD

Accessories required

Actuator is not included.

Wiring diagram
Wiring diagram

Connection examples

Connection examples

Technical data

Approvals

c_UL_us_E346349_1/1DGUV_ET 18055_ET 18056

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 75 V (Tested up to 75 V by employers' liability insurance association)
Rated impulse voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple