Manufacturer: Schneider Electric Barcode: 3606480379536 The C120N A9N18382 circuit breaker meets the requirements of the standards EN 60947-2, EN 60898-1 and combines the following functions:
Sign In Sign InPassword Forgotten?Don't have account? Create account SearchSearchClose Product added to basketGo to cartContinue shopping Questions Product categories 



- +7 (495) 663-73-29
- Wishlist
- Compare
- Send
VK
WhatsApp
Odnoklassniki
Copy link
- Model: 003.001.037
Manufacturer: Schneider Electric Barcode: 3606480379536 The C120N A9N18382 circuit breaker meets the requirements of the standards EN 60947-2, EN 60898-1 and combines the following functions:- protection of circuits against short-circuit currents
- overload current protection
- possibility of partitioning in industrial electrical installations in accordance with IEC / EN 60947-2
- fault signaling and emergency shutdown by means of optional accessories
- Description
- Nomenclature
- Delivery
Main
| range of product | C120 |
| range | Acti 9 |
| product name | C120 |
| product or component type | Miniature circuit-breaker |
| device short name | C120N |
| device application | Distribution |
| poles description | 2P |
| number of protected poles | 2 |
| neutral position | Left |
| [In] rated current | 63 A at 30 °C |
| network type | AC |
| trip unit technology | Thermal-magnetic |
| curve code | D |
| breaking capacity | 10000 A Icn at 230…400 V AC 50/60 Hz conforming to EN/IEC 60898-16 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-210 kA Icu at ≤ 250 V DC conforming to EN/IEC 60947-220 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-210 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| suitability for isolation | Yes conforming to IEC 60947-2 |
Complementary
| network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 380…415 V AC 50/60 Hz220…240 V AC 50/60 Hz440 V AC 50/60 Hz≤ 250 V DC230…400 V AC 50/60 Hz |
| magnetic tripping limit | 10…14 x In |
| [Ics] rated service breaking capacity | 7500 A 75 % conforming to EN/IEC 60898-1 - 230…400 V AC 50/60 Hz4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz7.5 kA 75 % conforming to EN/IEC 60947-2 - 380…415 V AC 50/60 Hz15 kA 75 % conforming to EN/IEC 60947-2 - 220…240 V AC 50/60 Hz10 kA 100 % conforming to EN/IEC 60947-2 - ≤ 250 V DC |
| limitation class | 3 conforming to EN/IEC 60947-2 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 |
| contact position indicator | Yes |
| control type | Toggle |
| local signalling | ON/OFF indication |
| mounting mode | Clip-on |
| mounting support | 35 mm symmetrical DIN rail |
| comb busbar and distribution block compatibility | YES |
| 9 mm pitches | 6 |
| height | 81 mm |
| width | 54 mm |
| depth | 73 mm |
| net weight | 0.41 kg |
| colour | White |
| mechanical durability | 20000 cycles |
| electrical durability | 10000 cycles conforming to IEC 60947-2 |
| connections - terminals | Tunnel type terminals1…50 mm² rigidTunnel type terminals1.5…35 mm² flexible |
| wire stripping length | 15 mm |
| tightening torque | 3.5 N.m |
| earth-leakage protection | Separate block |
Environment
| standards | EN/IEC 60898-1EN/IEC 60947-2 |
| product certifications | EAC |
| IP degree of protection | IP20 conforming to IEC 60529 |
| pollution degree | 3 conforming to IEC 60947-2 |
| overvoltage category | IV |
| tropicalisation | 2 conforming to IEC 60068-1 |
| relative humidity | 95 % at 55 °C |
| operating altitude | 2000 m |
| ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -40…85 °C |
Schneider Electric nomenclature of C120N circuit breakers
| Poles | Number of modules W=9mm | Rated current, A | Part No. Schneider Electric / Price | ||
|---|---|---|---|---|---|
| Curve B | Curve C | Curve D | |||
| 1 | 3 | 63 | A9N18340 | A9N18356 | A9N18378 |
| 80 | A9N18341 | A9N18357 | A9N18379 | ||
| 100 | A9N18342 | A9N18358 | A9N18380 | ||
| 125 | A9N18343 | A9N18359 | A9N18381 | ||
| 2 | 6 | 63 | A9N18344 | A9N18360 | A9N18382 |
| 80 | A9N18345 | A9N18361 | A9N18383 | ||
| 100 | A9N18346 | A9N18362$266.30 | A9N18384 | ||
| 125 | A9N18347 | A9N18363 | A9N18385 | ||
| 3 | 9 | 63 | A9N18348 | A9N18364$243.05 | A9N18386$606.44 |
| 80 | A9N18349 | A9N18365 | A9N18387 | ||
| 100 | A9N18350 | A9N18367 | A9N18388 | ||
| 125 | A9N18351 | A9N18369 | A9N18389 | ||
4![]() | 12 | 63 | A9N18352 | A9N18371 | A9N18390 |
| 80 | A9N18353 | A9N18372 | A9N18391 | ||
| 100 | A9N18354 | A9N18374 | A9N18392 | ||
| 125 | A9N18355 | A9N18376 | A9N18393 | ||
Dimensions circuit breaker C120N
Trip curves
Sign In Sign InPassword Forgotten?Don't have account? Create account SearchSearchClose Product added to basketGo to cartContinue shopping Questions Product categories Сайт использует рекомендательные технологии и файлы cookie
Từ khóa » C120n 63a
-
A9N18371 - Miniature Circuit-breaker, Acti9 C120N, 4P, 63 A, C ...
-
Miniature Circuit-breaker, Acti9 C120N, 4P, 63 A, C Curve, 10000 A ...
-
C120N 2P 63A C 10000A 415V MINIATURE CIR | Breakers - CNW
-
C120N - Circuit Breaker - 4P - 63A - C Curve • Rexel
-
Disjoncteur C120N 4P 63 A, Courbe C, 10 KA - Schneider - A9N18371
-
Circuit Breaker C120N A9N18371 4P 63A C - Scat
-
ACTI 9 C120N MCB 1P 63A C CURVE - Miniature Circuit Breaker ...
-
RS Components - Free CAD Models - Acti9 C120N MCB 4 Pole 63A ...
-
Schneider Electric Acti 9 C120N MCB, 4P Poles, 63A Curve C, 440V ...
-
SCHNEIDER - MCB Breaker, Acti9 C120N, 3P, 63A, C Curve
-
Buy Schneider 63A 2 Pole C120N B Miniature Circuit Breaker ...
-
Schneider Circuit Breaker 2p C 63A 10kA C120N Acti9 - MerXu
-
Schneider Electric Acti 9 C120N MCB, 3P Poles, 63A Curve C, 440V ...