CNDC : Free Flow Nose To Side Check Valve With Bypass Orifice

Skip to content

Assembly Build Process

  • X
  • ?
Assembly Build Process

Sun's Assembly Build Process allows you to configure a cartridge and manifold, or main stage and pilot stage cartridge, and build a digital assembly in three dimensional space. The resulting output of this process is the assembly product page, including configuration-specific images, symbols, product information and CAD files for download.

The Assembly Build Process can be accessed from either a cartridge or manifold product page. Only valid choices are allowed.

From a manifold page, you must first choose your cartridge function. Once you choose your function, click on the BUILD ASSEMBLY button below the WHERE TO BUY BUTTON. Once clicked, you will be presented with valid cartridges for your manifold. Select the cartridge of your choice and follow the instructions at the top of the page. If your particular combination has been generated before, the resulting assembly page will be available immediately. If not, you will be asked to enter your email address. Once the page is complete, an email will be sent to you including a link to the assembly product page.

From a cartridge product page, click on BUILD ASSEMBLY and you will be presented with a listing of compatible manifolds. In the case of main stage and pilot stage cartridges, you can either build a cartridge to cartridge assembly or a cartridge to manifold assembly. Once your choice has been made, follow the instructions at the top of the page. If your particular combination has been generated before, the resulting assembly page will be available immediately. If not, you will be asked to enter your email address. Once the page is complete, an email will be sent to you including a link to the assembly product page.

Please note that the Assembly Build Process is an automated process. It can be utilized at any time. Pages are generated typically within minutes but delays can occasionally be expected. In the event of a delay, a team at Sun will work to resolve the issue to ensure you receive your information as quickly as possible.

Assembly Build Process

Are you sure you want to clear your assembly build selections?

Clear Cancel
  • Cartridges
  • »
  • Directional
  • »
  • Check
  • »
  • 7.5 gpm CNBC 15 gpm CNDC 30 gpm CNFC 60 gpm CNHC 120 gpm CNJC 180 gpm CNKC
  • 30 L/min. CNBC 60 L/min. CNDC 120 L/min. CNFC 240 L/min. CNHC 480 L/min. CNJC 680 L/min. CNKC
  • »
  • Free flow nose to side check valve with bypass orifice Free flow side to nose check valve Free flow side to nose check valve with Delrin seat
  • Metric Units
  • U.S. Units
Cut Sheet Full Data Sheet Email ✕ Free flow nose to side check valve with bypass orifice Capacity: 15 gpm60 L/min. | Cavity: T-13A CNDC : Free flow nose to side check valve with bypass orifice
  • Technical Features
  • Technical Data
  • Performance Curves
  • FAQs
  • Additional Resources
Expand All Technical Features [ + ]

Free-flow, nose-to-side check valves with a bypass orifice allow free flow from port 1 to port 2. A customer specified orifice is included to restrict flow from port 2 to port 1. See technical data below for orifice range.

  • Two-port check valves share the same cavity for a given frame size, however, pay close attention as flow paths may be in opposite directions.
  • Will accept 5000 psi (350 bar) at ports 1 and 2.
  • Valves with the opposite flow path (free flow from 2 to 1) are considered flow controls and may be found listed as fixed orifice, non-pressure compensated flow control valve with reverse flow check.
  • The customer specified orifice diameter is stamped on one of the cartridge's hex faces.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP or /LH (see CONFIGURATION section). For further details, please see the Materials of Construction page.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Back to Top Technical Data [ + ] Note: Data may vary by configuration. See CONFIGURATION section.
Cavity T-13A
Series 1
Capacity 15 gpm60 L/min.
Maximum Operating Pressure 5000 psi350 bar
Orifice Range .016 - .107 in.0,4 - 2,7 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Seal kit - Cartridge Buna: 990010007
Seal kit - Cartridge Polyurethane: 990010002
Seal kit - Cartridge Viton: 990010006
Back to Top Performance Curves [ + ] Performance Curve for CNDC: Free flow nose to side check valve with bypass orifice Back to Top FAQs [ + ] How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct acting or pilot operated - what do I use?

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?

Because of the very high ratio, the COFO has limited capacity. The discharge path is across a .050 inch (1,3 mm) diameter orifice. If you have large accumulators combined with low precharge pressures, this may not discharge the energy quickly enough. Using the COFO XDN cartridge in conjunction with an LODA XDN will provide capacity for larger applications.

What parts of the Sun cartridge valve are field serviceable? Only external seals are serviceable. Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge. Back to Top Additional Resources [ + ] Highlights
  • Sun's New FLeX Series Solenoid Valves & Coils
  • Sun Offers Zinc-Nickel Plating for Corrosion Resistance
  • New FLeX Series Solenoid-Operated Directional Valves
  • Sun Expands Corrosion-Resistant Solutions
  • Sun Cartridges with EPDM Seals
  • Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
  • CavitySaver multi-function valves deliver single-cartridge solutions
  • Pilot Controlled Directional Cartridges Technical Tips
  • QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
  • Check Valves, Flow Control and Priority Flow Control Valves Technical Tips
Technical Tips
  • Manufacturing Sun Cartridge Cavities (522.27 KB)
  • Check, Flow Control, and Priority Flow Control Valves (537.44 KB)
Technical Information
  • Fluid Recommendations: Oil Viscosity, Cleanliness & Temperature
  • Sun's Floating Style Screw-In Cartridge (1.06 MB)
  • Units of Measure, Settings, and Conversions
  • Sun Model Code Explanation; 999-901-334 (343.9 KB)
  • Performance Data
  • Cartridges: Materials of Construction
  • Cavity Information (S-171) and Tooling
Back to Top Model reset to default

CNDCXCN

CNDC view all

Symbols for CNDC

CNDC CNDC Configuration Rules CONTROL [L]{Manual Load Release } [X]{Not Adjustable } SETTING RANGE [A]{4 psi (0,3 bar) Cracking Pressure, .016 - .107 in. (0,4 - 2,7 mm)} [B]{15 psi (1 bar) Cracking Pressure, .016 - .107 in. (0,4 - 2,7 mm)} [C]{30 psi (2 bar) Cracking Pressure, .016 - .107 in. (0,4 - 2,7 mm)} [D]{50 psi (3,5 bar) Cracking Pressure, .016 - .107 in. (0,4 - 2,7 mm)} [E]{75 psi (5 bar) Cracking Pressure, .016 - .107 in. (0,4 - 2,7 mm)} [F]{100 psi (7 bar) Cracking Pressure, .016 - .107 in. (0,4 - 2,7 mm)} [Z]{1 psi (0,07 bar) Cracking Pressure, .016 - .107 in. (0,4 - 2,7 mm)} SEAL MATERIAL [N]{Buna-N } [V]{Viton } MATERIAL/COATING [/AP]{Stainless Steel, Passivated} [/LH]{Mild Steel, Zinc-Nickel} [ ]{Standard Material/Coating} Where To Buy
  • If the modifier is /AP, the control must be X
  • If the modifier is /LH, the control must be L or X
Footer