Commissioning Siemens G120 Drives With Startdrive In TIA Portal
- Manufacturing Automation & Intelligence
- PLC
- Siemens PLC
- Allen Bradley PLC
- HMI and SCADA
- MES
- Motion Control
- Test and Measurement Automation
- Test Stand
- Battery Pack Test Systems
- Cloud-Enabled Test Systems
- LabVIEW
- Embedded Development & Programming
- Circuit Design
- Low-Power Embedded Design
- Product Development
- Application Development
- Web Application Development
- PC Application Development
- User Interface Design
- IoT
- Digital Workplace Solutions
- Azure
- Business Intelligence
- CRM
- Office 365
- SharePoint
- Announcements
- News
- Special Events
- Culture
- Activities
- Employee Bios
- Geek Challenge
- Quote Board
- Diversity, Equity, and Inclusion
- Family Fun
- Locations
- Chicago
- Austin
- Boston
- Cincinnati
- Dallas
- Denver
- Houston
- Nashville
- New York
- Seattle
- St. Louis
- San Diego
- Washington, D.C.
The built-in drive commissioning features in TIA Portal make it very simple to commission a Siemens G120 drive with a Siemens S7 PLC without the need for any stand-alone software. Drives can be commissioned quickly and easily, and afterwards all drive parameters will be stored in Portal for future reference. I have described the general process of setting up Profinet drives with safety in Portal step-by-step. Small details may vary with every situation, but the general process is as follows:
- Add the drive to Devices & Networks. If the drive has separate Control and Power Units, add the Power unit in the Device View of the Control Unit.
- Assign the IP address and Profinet Name in Devices & Networks. This IP address must be unique and on the same subnet as the PLC.
- Setup Safety Telegrams in Devices & Networks. Be sure to assign the Partner data area so that no tags are overlapping with tags used for logic.
- Assign Unique F-Addresses in Devices & Networks. Profinet F-addresses are only assigned through Portal and do not have the physical jumpers Profibus drives have.
- Set IP address and Profinet Name in the drive to match the one assigned in Devices & Networks. This is done through the Online Access > Device Interface> Online & Diagnostics > Functions. If the device has had a previous IP address assigned, make sure to reset the IP to factory default first. This will reset only the IP address and Name, not any previously assigned parameters or safety functionality. If a factory reset is not done, the IP address may return to the original setting after a few power cycles.
- Commission drive parameters using the commissioning wizard built into Portal and the specifications found on the motor faceplate.
- Commission drive safety through the functional view of the Parameter option. If commissioning multiple similar drives and copying the drives in the Device & Networks, you must “Activate the Safety Commissioning Mode” while online with each drive individually, even if no settings need to be changed.
- Test the drive by manually moving it in Portal’s control panel.
- Upload from drive to save motor parameters in Portal for later reference.
A more detailed description of the process can be found on Siemen’s website here.
Learn more about DMC's Siemens PLC programming services. Contact us for more information.
Comments
# Vorapob Sunday, June 26, 2016 9:11 PM Can you give me a manual and Example project for me please my email: tonsc2002@hotmail.com Thanks alot # Achraf Thursday, March 24, 2016 4:30 AM hi I want control the motion of servopack of yaskawa with one of PLCs of siemence can you helpe me please ?this is my email achraf.01bara@gmail.com thank you very muchPost a comment
Name (required)
Email (required)
Enter the code shown above:
Notify me of followup comments via e-mail
Popular Articles
Meet DMC On-Campus at a 2024 Career Fair 08/13/2024 The Future of Test and Measurement and NI Connect 2024 05/31/2024 DMC Recognized as CSIA 2024 Integrator Member of the Year 05/08/2024Related Services
- B&R Automation Studio Programming
- Beckhoff and TwinCAT 3 Programming
- Legacy PLC Upgrade and Conversion Services
- Mitsubishi PLC Programming and Automation Services
- Other PLC Platforms
Related Blog Posts
Getting Started with FactoryTalk Logix Echo Using Ethernet/IP Natively with TwinCAT Upgrading from WinCC Comfort to WinCC Unified- About
- Employee Bios
- Core Values
- Industries Served
- Partners
- Testimonials
- Customer Service
- Our Clients
- FAQ
- Latest Thinking
- Blog
- Case Studies
- Videos
- Press Room
- Newsletter
- Services
- Manufacturing Automation and Intelligence
- Test and Measurement Automation
- Embedded Development and Embedded Programming
- Application Development
- Digital Workplace Solutions
- Careers
- Benefits
- Diversity & Inclusion
- Locations
- Open Positions
- Contact
Từ khóa » G120c Tia V16
-
Simple Speed Control - G120 With TIA V16 - Entries - Forum
-
TIA Portal Add-In "SINAMICS G120X Basic Setup” - ID: 109792547
-
SINAMICS G120 With STARTDRIVE (Free Download) Part 1/2
-
SINAMICS G120 Comissioning Inside TIA Portal - YouTube
-
Commissioning A SINAMICS G120 Via Startdrive In TIA Portal
-
SINAMICS G120 With STARTDRIVE (Free Download) Part 2/2
-
Siemens: How To Upload A G120 Into TIA Portal - AWC, Inc.
-
Siemens_cp1616/Tutorials/SINAMICS G120 - TIA Portal Configuration
-
[PDF] Function Blocks To Control The SINAMICS With SIMATIC S7 In TIA
-
SINAMICS Startdrive | Phần Mềm Cấu Hình Biến Tần Siemens
-
Where Can I Download The SINAMICS Drive Library From?
-
TIA Portal V16 - Siemens 0... Page 3 V90 G120, G130, G150 S120 ...
-
Siemens#Using SINA_SPEED To Control G120 | - SOUP01
-
Siemens TIA Portal V15 G120C Drive Firmware - Interactive Q & A