Datasheet 2307252 Eaton 183034 Circuit ... - UserManual.wiki
Skip to content Home ›
File info: application/pdf · 4 pages · 245.42KB
File info: application/pdf · 4 pages · 245.42KB Datasheet 2307252 Eaton 183034 Circuit breaker 160 A 690 V AC
Eaton 183034 Circuit breaker 160 A 690 V AC Eaton 183034 4015081779611
Eaton 183034 Terhelés leválasztó kapcsoló 160 A 690 V/AC 1 db | Conrad
Original Document
If the viewer doesn’t load, open the PDF directly.
Extracted Text
DATASHEET - XNH00-S160-BT1 NH fuse-switch 3p box terminal 1,5 - 95 mm�; busbar 60 mm; NH000 & NH00 Part no. Catalog No. Delivery program Basic function EL-Nummer (Norway) Number of poles Mounting type Size Type of connection Rated operational current Front degree of protection (XNH installed) Rated operational voltage Rated operational voltage Rated conditional short-circuit current Flammability characteristics Description Successor to XNH00-S160-BT1 183034 1624009 Basic device 3 pole Busbars of 60 mm 00 Box terminal Ie A 160 IP20 (Operating status) IP2XC (Contact protection) IP10 (Handle cover open) Ue V AC 690 Ue V DC 440 kA 120 (500 V) 100 (690 V) Self-extinguishing as per UL 94 Current paths of electrolytic copper, silver-plated Cable connection optionally at the top or bottom 224550 120603 Technical data Electrical Standards Rated operational voltage Rated operational voltage Rated operational current Rated frequency Rated insulation voltage Total heat dissipation at Ith (without fuses) Heat dissipation at 80% (without fuses) Rated impulse withstand voltage Utilization category AC-23B Rated operating voltage Rated operating current Utilization category AC22B Rated operating voltage Rated operating current Utilization category AC-21B Rated operating voltage Rated operating current Utilization category DC-22B Rated operating voltage Rated operating current Utilization category DC21B Rated operating voltage Rated operating current Rated conditional short-circuit current IEC/EN 60947-3 Ue V AC 690 Ue V DC 440 Ie A 160 f Hz 40 - 60 Ui V AC 800 Pv W 14 Pv W 9 Uimp kV 8 Ue V AC 400 Ie A 160 Ue V AC 500 Ie A 160 Ue V AC 690 Ie A 160 Ue V DC 250 Ie A 160 Ue V DC 440 Ie A 160 kA 120 (500 V) 06/18/2021 Eaton 183034 ED2021 V80.0 EN 1 / 4 Rated short-time withstand current Max. fuse Size according to DIN VDE 0636-2 Max. permitted power loss per fuse link Lifespan, electrical Mechanical Front degree of protection (XNH installed) Icw kA Pv W Operations Ambient temperature �C Rated operating mode Activation Mounting position Altitude m Overvoltage category/pollution degree RoHS (in accordance with Directive 2002/95/EC of the European Parliament and Council) Direction of incoming supply Lockable Sealable Material characteristics Material Colour Flammability characteristics Halogen-free Voltage test Lifespan, mechanical Operations Track resistance Heat deflection temperature �C Terminal capacity Flange connection Bolt diameter Cable lug max. width mm Flat busbar mm Box terminal Stranded mm2 Copper strip Number of mm segments x width x thickness Box terminal Stranded mm2 Copper band Number of mm segments x width x thickness Clamp-type terminal Stranded mm2 Double clamp-type terminal Stranded mm2 100 (690 V) 7 000 / 00 12 300 IP20 (Operating status) IP2XC (Contact protection) IP10 (Handle cover open) -25 - +55 Permanent operation Dependent manual activation Vertical, horizontal Max. 2000 III/3 Yes as required (FLEX System) Yes, optional Yes, Standard Polyamide Grey Self-extinguishing as per UL 94 Yes Yes, sliding inspection windows 1400 CTI 600 125 M8 25 20 x 10 1,5 - 95 Cu 9 x 9 x 0,8 1,5 - 50 Cu 6 x 9 x 0,8 10 - 70 Cu/Al - Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation Heat dissipation per pole, current-dependent Equipment heat dissipation, current-dependent IEC/EN 61439 design verification In A 160 Pvid W 4.7 Pvid W 14 06/18/2021 Eaton 183034 ED2021 V80.0 EN 2 / 4 10.2 Strength of materials and parts 10.2.2 Corrosion resistance 10.2.3.1 Verification of thermal stability of enclosures 10.2.3.2 Verification of resistance of insulating materials to normal heat 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects 10.2.4 Resistance to ultra-violet (UV) radiation 10.2.5 Lifting 10.2.6 Mechanical impact 10.2.7 Inscriptions 10.3 Degree of protection of ASSEMBLIES 10.4 Clearances and creepage distances 10.5 Protection against electric shock 10.6 Incorporation of switching devices and components 10.7 Internal electrical circuits and connections 10.8 Connections for external conductors 10.9 Insulation properties 10.9.2 Power-frequency electric strength 10.9.3 Impulse withstand voltage 10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise 10.11 Short-circuit rating 10.12 Electromagnetic compatibility 10.13 Mechanical function Meets the product standard's requirements. Meets the product standard's requirements. Meets the product standard's requirements. Meets the product standard's requirements. Meets the product standard's requirements. Does not apply, since the entire switchgear needs to be evaluated. Does not apply, since the entire switchgear needs to be evaluated. Meets the product standard's requirements. Does not apply, since the entire switchgear needs to be evaluated. Is the panel builder's responsibility. Does not apply, since the entire switchgear needs to be evaluated. Does not apply, since the entire switchgear needs to be evaluated. Is the panel builder's responsibility. Is the panel builder's responsibility. Ui = 800 V AC Is the panel builder's responsibility. Is the panel builder's responsibility. The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. Is the panel builder's responsibility. The specifications for the switchgear must be observed. Is the panel builder's responsibility. The specifications for the switchgear must be observed. The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 7.0 Low-voltage industrial components (EG000017) / Fuse switch disconnector (EC001040) Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse switch disconnector ([email protected] [AKF058013]) Version as main switch No Version as safety switch No Max. rated operation voltage Ue AC V 690 Rated permanent current Iu A 160 Rated operation power at AC-23, 400 V kW 0 Conditioned rated short-circuit current Iq kA 120 Rated short-time withstand current lcw kA 7 Suitable for fuses NH00 Number of poles 3 With error protection No Type of electrical connection of main circuit Frame clamp Cable entry Other Equipped with connectors No Suitable for ground mounting No Suitable for front mounting 4-hole No Suitable for busbar mounting Yes Type of control element Cover grip Position control element Front side Motor drive optional No Motor drive integrated No Version as emergency stop installation No Degree of protection (IP), front side Other 06/18/2021 Eaton 183034 ED2021 V80.0 EN 3 / 4 Dimensions 06/18/2021 Eaton Industries GmbH 4 / 4 http://www.eaton.eu � 06/2021 by Eaton Industries GmbH Eaton 183034 ED2021 V80.0 ENTừ khóa » Nh00 Nh000 Wiki
-
Schmelzsicherung - Wikipedia
-
Datei:NH 000 g - Wikipedia
-
NH Fuses Explained - Swe-Check
-
Sucherungseinsatz NH00 = NH000?
-
Was Ist Eine NH Sicherung? – Aufbau & Funktion
-
DF Electric | Passion For Electric Protection – Fuse Links And Fuse ...
-
[PDF] Table Of Contents
-
[PDF] Sicherungssysteme - Siemens Industry Online Support
-
[PDF] Catalogo Completo - ITALWEBER
-
[PDF] Data Sheet 3NP5060-0HA13 - UserManual.wiki
-
NH Sicherungen Von NH-000 Bis NH-3 - Elektroartikel Langehein
-
[PDF] NH-Sicherungseinsätze - Hager