Datasheet - NHI-E-10-PKZ0 - Data Sheet Engine - Eaton

/0/1/082884_L.jpg 082884 NHI-E-10-PKZ0 Overview Specifications Resources /0/1/082884_L.jpg 082884 NHI-E-10-PKZ0 Standard auxiliary contact, NHI-E, 1 N/O, Can be fitted to the front, Screw terminals EL Number (Norway) 4315150 Standard auxiliary contact, Contacts N/O = Normally open: 1 N/O, For use with: DILM
  • General specifications
  • General information
  • Climatic environmental conditions
  • Terminal capacities
  • Electrical rating
  • Switching capacity
  • Contacts
  • Design verification
  • Technical data ETIM 9.0
General specifications Product nameEaton Moeller® series NHI Accessory Standard auxiliary contact Part no.NHI-E-10-PKZ0 EAN4015080828846 Product Length/Depth12 millimetre Product height35 millimetre Product width45 millimetre Product weight0.011 kilogram CertificationsUL 508UL File No.: E36332UL Category Control No.: NLRVCSA-C22.2 No. 14ULIEC/EN 60947-4-1CSA Class No.: 3211-05CSA File No.: 165628CECSA Product TradenameNHI Product TypeAccessory Product Sub TypeStandard auxiliary contact Catalog NotesCan be fitted to the front. Terminal designation differs to that of an auxiliary contact that can be fitted to the side General information Electric connection typeScrew connection Lifespan, electrical100,000 Operations Lifespan, mechanical100,000 Operations ModelTop mounting Mounting methodFront fastening Overvoltage categoryIII Pollution degree3 Product categoryAccessories Rated impulse withstand voltage (Uimp)4000 V AC Used withMotor protective circuit-breaker Climatic environmental conditions Ambient operating temperature - min-25 °C Ambient operating temperature - max55 °C Terminal capacities Terminal capacity (solid/flexible with ferrule)0.75 - 1.5 mm² Terminal capacity (solid/stranded AWG)18 - 16, Screw terminals Electrical rating Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V1 A Rated operational current (Ie) at DC-13, 24 V2 A Rated operational voltage (Ue) at AC - max440 V Rated operational voltage (Ue) at DC - max250 V Safe isolation440 V, Between auxiliary contacts and main contacts, According to EN 61140 Short-circuit protection rating without welding10 A gG/gL, Fuse, Auxiliary contacts Switching capacity Switching capacity (auxiliary contacts, general use)0.5 A, 250 V DC, (UL/CSA) Switching capacity (auxiliary contacts, pilot duty)E150, AC operated (UL/CSA) Contacts Number of contacts (change-over contacts)0 Number of contacts (normally closed contacts)0 Number of contacts (normally open contacts)1 Design verification Equipment heat dissipation, current-dependent Pvid0 W Heat dissipation capacity Pdiss0 W Heat dissipation per pole, current-dependent Pvid0.01 W Rated operational current for specified heat dissipation (In)1 A Static heat dissipation, non-current-dependent Pvs0 W 10.2.2 Corrosion resistanceMeets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements. 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements. 10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated. 10.2.7 InscriptionsMeets the product standard's requirements. 10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distancesMeets the product standard's requirements. 10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility. 10.8 Connections for external conductorsIs the panel builder's responsibility. 10.9.2 Power-frequency electric strengthIs the panel builder's responsibility. 10.9.3 Impulse withstand voltageIs the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility. 10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041) Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss13-27-37-13-02 [AKN342018]) Number of contacts as change-over contact0 Number of contacts as normally open contact1 Number of contacts as normally closed contact0 Number of fault-signal switches0 Rated operation current Ie at AC-15, 230 V1 A Type of electric connectionScrew connection ModelClip-on Mounting methodFront fastening Lamp holderNone

Product photo

  • 082884_C.jpg Photo
  • 082884_R.jpg Photo
  • 082884_L.jpg Photo

CAD data

  • Product-specific CAD data (Web)
  • 3D Preview (Web)
  • nhi_e_1.stp Asset
  • DA-CS-nhi_e Asset
  • DA-CD-nhi_e Asset
  • ETN.082884.edz Asset

Instruction Leaflet

  • eaton-front-mounted-auxiliary-contact-nhi-il03801004z.pdf Asset

Drawing

  • eaton-manual-motor-starters-auxiliary-contact-nhi-accessory-3d-drawing-002.eps Line drawing
  • eaton-manual-motor-starters-auxiliary-contact-nhi-accessory-3d-drawing-005.eps Line drawing

Characteristic curve

  • eaton-motorstarters-auxiliary-contact-nhi-accessory-characteristic-curve-007.eps Coordinate visualization

Wiring diagram

  • eaton-manual-motor-starters-auxiliary-contact-nhi-accessory-wiring-diagram-004.eps Line drawing

Brochure

  • eaton-motor-starters-system-xstart-brochure-br03407001en-en-us.pdf Asset

Catalog

  • Switching and protecting motors - catalog Asset
  • Product Range Catalog Switching and protecting motors Asset
  • eaton-product-overview-for-machinery-catalogue-ca08103003zen-en-us.pdf Asset
  • Produktübersicht für den Maschinenbau Asset
  • Sortimentskatalog Motoren schalten und schützen Asset
  • eaton-product-overview-machine-building-catalog-ca08103003z-de Asset

Dimensions single product

  • eaton-manual-motor-starters-pkz0-accessory-dimensions.eps Line drawing
  • eaton-manual-motor-starters-pkz-dimensions-003.eps Line drawing

Service

  • WIN-WIN mit Push-in-Technik
  • WIN-WIN with push-in technology
  • eaton-link-module-for-motor-starters-pkz-flyer-fl034003en-en-us.pdf

Download-Center

  • Download-Center (this item) Eaton EMEA Download-Center - download data for this item
  • Download-Center Eaton EMEA Download-Center
Generate data sheet in PDF format Generate data sheet in Excel format Write a comment

Từ khóa » Nhi-e-10-pkz0