DINUY CO K5X 002 Operation And Installation Manual - ManualsLib

× Bookmark added × Added to my manuals
  1. Manuals
  2. Brands
  3. DINUY Manuals
  4. Transceiver
  5. CO K5X 002
  6. Operation and installation manual
DINUY CO K5X 002 Operation And Installation Manual Knx rf/tp coupler Hide thumbs 1 2 3 4
  • Contents
  • Table of Contents
  • Bookmarks
Table of Contents
  • Application
  • Installation and Connection
  • Coupler Function
  • KNX Programming Mode
  • Manual Operation and Status Display
  • Manual Operation TP
  • Manual Operation RF
  • Factory Default Settings
  • Reset to Factory Device Settings
  • ETS Database
  • ETS Parameter Dialogue
  • General Settings
  • Repeater
  • Routing (TP Line → RF Line)
  • Routing (RF Line → TP Line)
  • Repetition of Broadcast Telegrams
  • Filter Table

Quick Links

Download this manual Enlarged version EN Operation and installation manual CO K5X 002 – KNX RF/TP Coupler

Application

The KNX RF/TP Coupler is a compact KNX radio coupler. It connects KNX RF devices of a radio line with the KNX Bus Twisted Pair. The device has a filter table for group addresses. The coupler supports long frames and is compatible with the ETS® software ETS5 or higher. The buttons on the front panel allow disabling the telegram filter for testing purposes. The LEDs indicate operating conditions as well as communication errors on the KNX bus. The power is supplied via the KNX bus.

Coupler function

KNX RF/TP Coupler as line coupler The individual address assigned to the KNX RF/TP Coupler in the form of x.y.0 (x, y: 1..15) sets up, that the device operates as a line coupler. The KNX RF/TP Coupler has a filter table and thus contributes to reducing the bus load. The filter table supports the extended group address range (main group 0..31) and is automatically generated by the ETS.

Installation and Connection

The device can be flush-mounted, the housing fits into a stan- dard flush-mounted box. When choosing the installation location the range of RF devices to be associated with the gateway has to be considered. Shield- ing objects (e.g. metal cabinets) or interfering transmitters (e.g. computers, electronic transformers, ballasts) near the gateway should be avoided. The connection to the KNX bus is made with a bus connector. The correct polarity of the terminal referred to the printing inside the unit has to be considered. The KNX RF/TP Coupler features the following controls and displays: An external power supply is not necessary as the device is powered by the KNX bus. The device is not working without bus power.

KNX Programming mode

The KNX programming mode is activated/deactivated by press- ing the KNX programming button mode is active, the programming LED A gateway ex-factory has the default individual address 15.15.0.

Manual operation and status display

❹ The State LED lights up if the device is successfully powered by the KNX bus. This LED blinks red, when the application is not running, e.g. after a failed ETS download. The State LED lights up orange to indicate that manual operation is active. ❺ The LEDs 1-4 show TP traffic. ❺ The LEDs 5-8 show RF traffic.

Manual operation TP

❻ Pressing button A short, enters the manual operation for TP mode. ❻ By pressing button A , routing runtime telegrams (group telegrams) will be enabled/disabled. This will be indicated by ❺ LEDs 1 and 2 . ❼ By pressing button B , routing management telegrams (indi- vidual addressed and broadcast telegrams) will be enabled/disabled. This will be indicated by LEDs 3 and 4 ❶ Button P KNX Prog ❷ LED P KNX Prog ❸ KNX bus connector ❹ LED S State ❺ LEDs 1-8 ❻ Button A ❼ Button B ❶ . When the programming ❷ lights red. ❹ ❺ . Page 1/4 Table of Contents Previous Page Next Page
  • 1
  • 2
  • 3
  • 4
Table of Contents loading Need help?

Need help?

Do you have a question about the CO K5X 002 and is the answer not in the manual?

Ask a question

Questions and answers

Summary of Contents for DINUY CO K5X 002

  • Page 1 Operation and installation manual CO K5X 002 – KNX RF/TP Coupler Installation and Connection The device can be flush-mounted, the housing fits into a stan- dard flush-mounted box. When choosing the installation location the range of RF devices to be associated with the gateway has to be considered. Shield- ing objects (e.g.
  • Page 2 The ETS database (for ETS 5) can be downloaded from the Manual operation RF product website of the KNX RF/TP Coupler: www.dinuy.com. ❼ Pressing button B short, enters the manual operation for RF mode.
  • Page 3 Routing (TP line  RF line) Routing (RF line  TP line) Group telegrams Group telegrams Block: No group telegrams are routed to the RF line. Block: No group telegrams are routed to the TP line. Route: All group telegrams are routed to the RF line independent of the filter table.
  • Page 4  For planning and construction of electric in- stallations, the relevant guidelines, regulations and standards of the respective country are to be considered. Property window of a group address DINUY S.A. C/Auzolan 2, 20303 Irún (Spain) http://www.dinuy.com [email protected] Page 4/4...

Table of Contents

Print

Print page 1 Print document (4 pages)

Rename the bookmark

Cancel

Delete bookmark?

Cancel Delete

Delete from my manuals?

Cancel Delete

Login

Sign In OR Sign in with Facebook Sign in with Google Don't have an account? Sign up! Restore password

Upload manual

Upload from disk Upload from URL Thank you for your help!

Từ khóa » Dinuy Em K5x 002