Does Anyone Know What Error Code CH 05 Means? A
Skip to
- Main content
Keyboard shortcuts
To move between items, use your keyboard's up or down arrows.
FRIEDRICH M24YJ FRIEDRICH DUCTLESS MINI-SPLIT HEAT PUMP SYSTEM 24000 BTU 230 VOLT 21.5 SEER (1/EA)
Q: Does anyone know what error code CH 05 means?
asked on June 22, 2016
Answer in a video or photo
This file format is not supported
Videos must be at least 5 seconds.
The file size is too big. A video can be up to 1 GB
We encountered a problem while trying to upload. Please try again
You have uploaded the maximum number of photos
You may only upload one video per answer
Sign-in is requiredDon't feel like typing? Answer in a video or photo
Write your answer
You can't submit while content is uploading. Please try again once your upload is complete Please add a video, photo or a written answerShowing 1-1 of 1 answers
Will :Fault Code 05This fault code indicates a communication error bet… see more Will :Fault Code 05This fault code indicates a communication error between the indoor and outdoorunits; this is usually caused by wiring errors or condensate pumps connected to theinter-connecting cable.The communication between the units is a fluctuating DC voltage commonly called aserial signal, it can be easily lost if the wiringis not done correctly. If there is acommunication error faultCH05will appear within 5 mins of powering up the system.TestingTurn on the power and start the indoor unit in cooling, set the temperature to 18ºC,the serial communication signal will only be present for the first 3 mins of operation.Set your meter to DC Volts, Test between terminals2 and 3, of the outdoor unit andwiring terminals you should see 0-65 V dc, it willbe fluctuating.If the Voltage is not present disconnect the interunit wiring, test the Voltage on thewiring terminals again, If No Voltage is present the outdoor PCB must be faulty.Once the signal has been detected leaving the outdoor unit check what is beingreceived by the indoor unit, measure DC Voltage across the wiring terminal 2 and 3,it should be identical to what you saw at the outdoor unit, if not your wiring is at fault.Will :http://www.ksservices.com/PDFs/LG/Multi%20and%20CAC%20Fault%20Codes%20v%201.1%282%20digit%29.pdfWill :above is a link to LG single or split units the communications fault could have easily been caused by a voltage spike from the power outage you had, as I read this, I take it the unit was operating fine prior to the outage and then the communications error oWill :05 then CH05 within 5 minutes of having power applied, a short in the wiring, from the surge, the PCB which in the LG troubleshooting points to if the voltage readings are as described, could have been damaged by a surge also, I would follow the steps with a volt meter, and then you will have to inspect the wiring then replace the PCB if there was enough surge the wiring issue may be visual just depends on the magnitude, the last statement in the troubleshooting is confusing it all runs togetherOnce the signal has been detected leaving the outdoor unit check what is beingreceived by the indoor unit, measure DC Voltage across the wiring terminal 2 and 3,it should be identical to what you saw at the outdoor unit, if not your wiring is at fault.Will :That last sentence should read something like I have rewritten Once the [communication] signal [voltage] has been detected leaving the outdoor unit then check what is beingreceived by the indoor unit, measure DC Voltage across the wiring terminal 2 and 3,it should be identical to what you saw at the outdoor unit, if not your wiring is at fault. see less Will :Fault Code 05This fault code indicates a communication error between the indoor and outdoorunits; this is usually caused by wiring errors or condensate pumps connected to theinter-connecting cable.The communication between the units is a fluctuating DC voltage commonly called aserial signal, it can be easily lost if the wiringis not done correctly. If there is acommunication error faultCH05will appear within 5 mins of powering up the system.TestingTurn on the power and start the indoor unit in cooling, set the temperature to 18ºC,the serial communication signal will only be present for the first 3 mins of operation.Set your meter to DC Volts, Test between terminals2 and 3, of the outdoor unit andwiring terminals you should see 0-65 V dc, it willbe fluctuating.If the Voltage is not present disconnect the interunit wiring, test the Voltage on thewiring terminals again, If No Voltage is present the outdoor PCB must be faulty.Once the signal has been detected leaving the outdoor unit check what is beingreceived by the indoor unit, measure DC Voltage across the wiring terminal 2 and 3,it should be identical to what you saw at the outdoor unit, if not your wiring is at fault.Will :http://www.ksservices.com/PDFs/LG/Multi%20and%20CAC%20Fault%20Codes%20v%201.1%282%20digit%29.pdfWill :above is a link to LG single or split units the communications fault could have easily been caused by a voltage spike from the power outage you had, as I read this, I take it the unit was operating fine prior to the outage and then the communications error oWill :05 then CH05 within 5 minutes of having power applied, a short in the wiring, from the surge, the PCB which in the LG troubleshooting points to if the voltage readings are as described, could have been damaged by a surge also, I would follow the steps with a volt meter, and then you will have to inspect the wiring then replace the PCB if there was enough surge the wiring issue may be visual just depends on the magnitude, the last statement in the troubleshooting is confusing it all runs togetherOnce the signal has been detected leaving the outdoor unit check what is beingreceived by the indoor unit, measure DC Voltage across the wiring terminal 2 and 3,it should be identical to what you saw at the outdoor unit, if not your wiring is at fault.Will :That last sentence should read something like I have rewritten Once the [communication] signal [voltage] has been detected leaving the outdoor unit then check what is beingreceived by the indoor unit, measure DC Voltage across the wiring terminal 2 and 3,it should be identical to what you saw at the outdoor unit, if not your wiring is at fault.- ←Previous
- 1
- Next→
|
- Careers
- Blog
- About Amazon
- Investor Relations
- Amazon Devices
- Amazon Science
- Sell products on Amazon
- Sell on Amazon Business
- Sell apps on Amazon
- Become an Affiliate
- Advertise Your Products
- Self-Publish with Us
- Host an Amazon Hub
- See More Make Money with Us
- Amazon Business Card
- Shop with Points
- Reload Your Balance
- Amazon Currency Converter
- Amazon and COVID-19
- Your Account
- Your Orders
- Shipping Rates & Policies
- Returns & Replacements
- Manage Your Content and Devices
- Help
Amazon Music
Stream millionsof songsAmazon Ads
Reach customerswherever theyspend their time6pm
Score dealson fashion brandsAbeBooks
Books, art& collectiblesACX
Audiobook PublishingMade EasySell on Amazon
Start a Selling AccountVeeqo
Shipping SoftwareInventory Management
Amazon Business
Everything ForYour BusinessAmazonGlobal
Ship OrdersInternationallyAmazon Web Services
Scalable CloudComputing ServicesAudible
Listen to Books & OriginalAudio PerformancesBox Office Mojo
Find MovieBox Office DataGoodreads
Book reviews& recommendationsIMDb
Movies, TV& Celebrities
IMDbPro
Get Info EntertainmentProfessionals NeedKindle Direct Publishing
Indie Digital & Print PublishingMade EasyPrime Video Direct
Video DistributionMade EasyShopbop
DesignerFashion BrandsWoot!
Deals and ShenanigansZappos
Shoes &ClothingRing
Smart HomeSecurity Systems
eero WiFi
Stream 4K Videoin Every RoomBlink
Smart Securityfor Every HomeNeighbors App
Real-Time Crime& Safety AlertsAmazon Subscription Boxes
Top subscription boxes – right to your doorPillPack
Pharmacy Simplified
- Conditions of Use
- Privacy Notice
- Consumer Health Data Privacy Disclosure
- Your Ads Privacy Choices
Từ khóa » Ch05 Lg Ac
-
How To Resolve A CH05 Error In An LG Inverter AC - Quora
-
CH05 And CH53 Error Codes | Troubleshooting LG Comercial Air ...
-
LG RAC : Trouble Shooting Guide (Error Code CH05) I LG - YouTube
-
LG Multi V : Trouble Shooting Guide (Error Code CH05, 53, 237)
-
SOLVED: Lg Error Code Ch 05 - Fixya
-
[PDF] LG Air Conditioning Multi F(DX) Fault Codes Sheet Macedo - 1
-
LG General Wall Mounted-Inverter Type Svc Manual [Page 57]
-
[PDF] Lg Dual Inverter Ac Error Code Ch 05 - Weebly
-
Troubleshooting Ch05, Ch53, Check Point | LG LCN240CP User ...
-
LG Inverter AC CH05 Problem Solve #technology #Error - Facebook
-
40 LG Ac Error Codes And Troubleshooting (FULL LIST)
-
LG Air Conditioner - CH05 Error Code - Udon Thani Thailand Forum
-
From India, My Lg Inverter Ac Is Showing Error Code Ch 05 - JustAnswer
-
Getting CH05 Error, Communication Between Unit To Heads On LG ...