Issue MATEC Web Conf. Volume 101, 2017 Sriwijaya International Conference on Engineering, Science and Technology (SICEST 2016)
Article Number 03002
Number of page(s) 6
Section Mechanical, Industrial and Manufacturing Engineering
DOI https://doi.org/10.1051/matecconf/201710103002
Published online 09 March 2017
MATEC Web of Conferences 101, 03002 (2017)

Effect degree of temperature subcooling in the performance of refrigeration with CFC, HFC and hydrocarbons refrigerant

Prayudi Suparmin*, Vendy Antono and Roswati Nurhasanah

College of Engineering Technology PLN, Mechanical Engineering Department, 11750 Jakarta, Indonesia

* Corresponding author: [email protected]

Abstract

Global warming is the result of the use of Chloro Fluoro Carbon (CFC) and Hydro Flouro Carbon (HFC) refrigerants. CFC and HFC refrigerants are not environmentally friendly in air conditioning systems. Researchers conducting the research to find an alternative refrigerant with hydrocarbon and the use of liquid suction heat exchanger (LSHX) subcooling in the vapor compression refrigeration system. One kind of LSHX is heat exchanger between tube to tube. Retrofit refrigerant is used to find a replacement refrigerant for R22, R134a, R404A with R600, and mixture refrigerant R290/R600a in the ratio 50:50. From the analysis are conclude that the increases of degree of subcooling temperature significantly affects to the effectiveness of LSHX, increase the refrigeration capacity and also refrigeration capacity index, increase the compressor of work, compressor work of index, COP and COP index. The parameters of the indicators that mixture the refrigerant R290/R600a in the ratio of 50:50 can be used as a substitution for R404A and R22, while the R600 refrigerant can be used as a substitution for R134a in the vapor compression refrigeration system with LSHX.

© The Authors, published by EDP Sciences, 2017

Licence Creative CommonsThis is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Current usage metrics About article metrics Return to article

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.

Homepage Table of ContentsPrevious articleNext article

Article contents

  • Abstract
  • PDF (741.1 KB)
  • References

Metrics

  • Show article metrics

Services

  • Articles citing this articleCrossRef (3)
  • Same authors- Google Scholar- EDP Sciences database
  • Recommend this article
  • Download citation

Related Articles

Analytical computation of thermodynamic performance parameters of actual vapour compression refrigeration system with R22, R32, R134a, R152a, R290 and R1270 MATEC Web of Conferences 144, 04009 (2018) Analytical computation of thermodynamic performance parameters of actual vapour compression refrigeration system with R22, R32, R134a, R152a, R290 and R1270 MATEC Web of Conferences 144, 04009 (2018) Performance computation of window air conditioner with very low GWP near azeotropic refrigerant mixtures as a drop in Substitutes to R22 MATEC Web of Conferences 144, 04007 (2018) Performance computation of window air conditioner with very low GWP near azeotropic refrigerant mixtures as a drop in Substitutes to R22 MATEC Web of Conferences 144, 04007 (2018) Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290 MATEC Web of Conferences 159, 01051 (2018) More

Bookmarking

  • Mendeley
  • Reader's services
  • Email-alert

Từ khóa » Hfc Cfc 2017