Error Codes > Sharp > MX3100N > Code H4-30 - PrintCopy .info

Sharp MX3100N All About this machine Error Code: All codes A0-01 A0-02 A0-10 A0-11 A0-12 A0-20 A0-21 A0-22 C1-10 C1-14 C4-00 C4-02 C4-03 C4-10 E7-01 E7-03 E7-04 E7-05 E7-06 E7-08 E7-09 E7-10 E7-11 E7-14 E7-20 E7-21 E7-22 E7-23 E7-28 E7-29 E7-50 E7-55 E7-60 E7-61 E7-65 E7-80 E7-90 EE-EC EE-EL EE-EU F1-00 F1-03 F1-08 F1-10 F1-11 F1-15 F1-19 F1-20 F1-21 F1-31 F1-32 F1-33 F1-34 F1-36 F1-37 F1-38 F1-39 F1-41 F1-43 F1-45 F1-47 F1-50 F2-22 F2-23 F2-24 F2-25 F2-39 F2-40 F2-41 F2-42 F2-43 F2-45 F2-49 F2-50 F2-51 F2-58 F2-64 F2-65 F2-66 F2-67 F2-70 F2-71 F2-72 F2-73 F2-74 F2-75 F2-76 F2-77 F2-78 F3-12 F3-22 H2-00 H2-01 H2-02 H2-03 H3-00 H3-01 H3-02 H4-00 H4-01 H4-02 H4-30 H5-01 H7-10 H7-11 H7-12 L1-00 L3-00 L4-02 L4-04 L4-05 L4-06 L4-11 L4-16 L4-30 L4-31 L4-32 L4-35 L4-50 L4-56 L4-58 L6-10 L8-01 L8-02 L8-20 PC-- U1-01 U2-00 U2-05 U2-10 U2-11 U2-22 U2-23 U2-24 U2-30 U2-50 U2-80 U2-81 U2-90 U2-91 U6-00 U6-01 U6-02 U6-09 U6-10 U6-20 U6-21 U6-22 U6-50 U6-51 U7-50 U7-51 UC-02 UC-20
  • Code: H4-30
  • Description: Thermister input circuit trouble (TH_UM)
  • Causes: The values of TH_UM_AD1 and TH_UM_AD2 do not exceed the specified value (50 counts in AD value) within the specified time from turning ON the HL_UM. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble
  • Remedy: Replace the thermister. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble.
Used for the following models 4
  • Sharp MX2600G
  • Sharp MX2600N
  • Sharp MX3100G
  • Sharp MX3100N
Error Code
Parts Catalog
Service Mode, Troubleshooting
Downloads Files
Home