G.652.D Vs G.657.A1 & G.657.A2 Singlemode Fibre Differences
What does the term singlemode fibre cover?
Various types of fibre under the “singlemode” umbrella
On hearing the term “singlemode fibre”, the first thing that comes to mind for many of us is the core size of 9/125µm and it being used to transmit at a wavelength of 1310nm. However, the fibre also has to meet many other criteria which vary depending on type of singlemode fibre.
Below we discuss the various types and how they differ.
Online chat
Our team are available to offer support
The main definition for singlemode fibre
ITU-T G.652.D
Unless specifically stated, it is commonly accepted among networking professionals that when requesting singlemode fibre cables they will conform to ITU-T (International Telecommunication Union Telecommunication) G.652.D.
This standard is applicable to both singlemode OS1 and OS2 cables and describes the geometrical, mechanical and transmission attributes of the cable and ensures that the cable can be used in the operating wavelengths around 1310nm and 1550nm.
There are also other variations of G.652 (A to C) which are now considered to be legacy fibre standards because they do not support the full range of modern-day requirements such as Coarse Wavelength Division Multiplexed (CWDM) transmission or Wavelength Division Multiplexing (WDN).
Buy from a UK based company
Our team are available to offer support
Types of singlemode fibre
ITU-T G.657
However, with the demand for ever higher fibre density and the constraints this creates, it is becoming more common for networking professionals to require singlemode fibre that performs in more constrained areas with tighter cable routing and reduced bend radii.
When this is the case, singlemode fibre meeting the G.657 (characteristics of a bending-loss insensitive single-mode optical fibre and cable) standard may be required. G.657.A1 or G.657.A2 are typically requested although there are other standards. Cables meeting either of these standards are often referred to as Bend Insensitive (BI) or Reduce Bend Sensitive (RBS) fibre cable.
Are G.652 and G.657 compatible?
G.652.D, G.657.A1 and G.657.A2 all have the same physical size with internal and external core diameters of 9μm and 125μm, respectively.
This means that cables defined under all three standards are completely compatible with each other.
Telecordia GR-1435
Our cables are designed and tested to meet and surpass modern data centre standards such as Telcordia GR-1435
Please contact us for more information
What are the options for G.657 bend insensitive singlemode fibre?
G.657 categories
The ITU standard splits cables into two categories of G.657: category A for access networks and category B for short distances at the end of networks where space is at even more of a premium.
Within categories A and B, G657 is split further into:
G.657.A1 and G.657.A2 G.657.B2 and G.657.B3
Most environments related to data and telco applications typically do not require cables to perform to category B so we only discuss category A cables below.
G.657.A1 vs G.652.D
A key difference between G.657.A1 and G.652.D is the minimum bend radius a cable can be bent without the cable causing a network to experience failures.
G.657.A1 has a bend radius of 10mm without impacting performance. Whereas G.652.D has a larger minimum bend radius of 30mm.
Note these bend radius are for single singlemode cables in the initial manufactured form with just their primary buffered coating and before they are given outer sheaths or put into multicore constructions as these changes to the cable will also affect the minimum bend radius.
As such, thicker sheath cables or larger multicore cable constructions typically do not use G657.A1 or A2 cores as the limiting factor on the bend radius is the physical limitations of the cable construction and not the glass core.
G.657.A1 vs G.657.A2
G.657.A2 is also compliant with G.652.D while having a tighter minimum bend radius of 7.5mm, compared to 10mm for G.657.A1.
Because of its tighter bend radius and compliance with G.652.D, G.657.A2 is popular for use in tighter spaces within high density patching fields in data centres. Many of our customers from larger telecommunication companies also ask for G.657.A2 for the same reason.
When using G.657.A2, it is recommended that the smallest cable sheath diameter is used so the sheath does not restrict the cables minimum bend radius. Similarly, short booted connectors are also specified as often the tightest bend is at the connection point. For similar reasons of maintaining performance and maximising the benefit of using G657.A2 fibre, these cables are made with a lower loss ferrule and polished to give an IL (typical) <0.15dB and <0.20dB (Max).
Adding 100G ports to your network?
Use best practice with our plug and play, easily installable MTP® (MPO) system
READ MOREG.657.B2 and G.657.B3
Category B of G.657 has an even tighter bending radius than category A. B2 has a minimum bend of 7.5mm and B3 has 5mm, the lowest radius available for singlemode fibre patch cables.
Cost of singlemode G.657.A1 and G.657.A2 fibre patch leads
The production costs vary for singlemode fibres made to the different standards. Cables with a tighter bend radius tend to cost more due to the volumes produced and the higher specification required.
Our typical price for a 1m LC to LC singlemode duplex (1.8mm) cable with short boots is as follows:
Fibre | Bend Radius | Price |
G.657.A1 | 10mm | £4.05 |
G.657.A2 | 7.5mm | £4.15 |
It can be seen that as the cables get longer the price differential gets bigger.
Our low loss patch cords stock in different bend insensitive fibres all have a typical insertion loss of 0.15d/b.
Connectors and boot compatibility with bend insensitive fibre
G.652 and G.657 are compatible with all standard connectors such as LC, SC, MU, and E2000 in UPC or APC polishes.
Our pre-terminated singlemode fibre patch leads are available with all standard boot specifications, such as short boots, flexible boots, and fixed angle boots.
Fibre patch leads and CPR compliance
A range of cable construction types are also available that comply with Construction Products Regulation (CPR), depending on your requirement.
We can supply LSZH up to B2ca patch cables while maintaining performance with the different singlemode bend insensitive fibres.
Benefits of using G.657 bend insensitive singlemode fibre
The tighter bend radius without affecting performance explained above is the clear benefit of using G.657.
G.657 is ideal for:
- Installation in tight spaces due to the more flexible cables
- Use in cabinets, enclosures, and racks where space is at a premium
G.657.A1 singlemode fibre patch leads
Singlemode G657.A1 Simplex
LC, LCA, SC & SCA
View / Buy Online
Singlemode G657.A1 Duplex
LC, LCA, SC & SCA
View / Buy Online
Get in touch
If you have more questions about singlemode fibre, or any other requirements, can contact our team by phone, online chat or email on the details below.
Call our sales team
+44 (0)20 8286 6529
Online Chat (No AI)
Chat hereEmail our Sales Team
sales@completeconnect.co.uk
Talk to an expert
+44 (0)20 8286 6529
Got a question?
Live chat with an expert
Email us for expert advice
tech@completeconnect.co.uk
To provide the best browsing experience possible, our site uses cookies. By continuing to use our site, you accept the use of cookies. Learn more about the cookies we use.
ACCEPT ClosePrivacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience. Necessary Necessary Always Enabled Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information. Non-necessary Non-necessary Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website. SAVE & ACCEPTTừ khóa » G652d Vs G657a2
-
G652D Vs. G657A2 - What's The Difference? - CBO GmbH
-
G652D Vs G657A2 Singlemode Optical Fibre Differences And ...
-
Single Mode Optical Fibers: G652D Vs G657A2 - YouTube
-
Is G.652 Single Mode Fiber Your Right Choice? - FS Community
-
G.657A2 Vs. G.652D Fiber Bending Resistance Real Comparison
-
What Is The Difference Between G652D G657A1 G657A2 - Knowledge
-
The Difference Between G652,G657A,G655 And G654 - ETU-Link
-
BendBright™ XS (G.657.A2 And G.652.D) | Prysmian Group
-
[PDF] ITU-T G.657 Fibres:
-
G652D And G657A2 And PVC /LSZH Outer Sheath Patch Cord ...
-
[PDF] One Fibre Everywhere? - Corning
-
[PDF] Single-Mode Optical Fiber Selection Guide
-
สาย Fiber Optic Cable Single-mode ชนิด G.652D ต่างกับ G.657A อย่างไร