G4ODC24 - G4 DC Output 5-60 VDC, 24 VDC Logic - Opto22

Products > G4ODC24
G4ODC24
Hover over image to zoom in G4ODC24 G4 DC Output 5-60 VDC, 24 VDC Logic

Please contact your local distributor for pricing and purchase information.

Data Sheet Production Specification
  • Description
  • Specifications
  • Documents
  • Downloads
  • Videos & Demos

G4 I/O family

The G4ODC24 is a digital DC output module with an output voltage range of 5-60 VDC, requiring a typical logic voltage of 24 VDC. It is not for use with Opto 22 brains or with a Raspberry Pi, which use 5 VDC logic.

The module includes a built-in LED status indicator and a removable fuse.

G4 DC output modules are used to control or switch DC loads. Each module provides up to 4000 volts of optical isolation (transient) between field devices and control logic. Typical applications for DC output modules include switching loads such as DC relays, solenoids, motor starters, lamps, and indicators.

Units

G4ODC5* G4ODC5FM**

G4ODC5A* G4ODC5AFM**

G4ODC5MA*

G4ODC15***

G4ODC24***

G4ODC24A***

Maximum line voltage

VDC

60

200

60

60

60

200

Output voltage range

VDC

5–60

5–200

5–60

5–60

5–60

5–200

Key feature

Diagnostic switch

Current rating: At 45 °C ambient At 70 °C ambient

A A

3 2

1 0.55

3 2

3 2

3 2

1 0.55

Isolation input-to-out­put (transient): 1 ms 1 minute

volts

4000 1500

4000 1500

4000 1500

4000 1500

4000 1500

4000 1500

Off-state leakage at maximum voltage

mA

1

1

1

1

1

1

Control resistance (Rc in schematic)

Ohms

220

220

220

1 K

2.2 K

2.2 K

One-second surge

A

5

5

5

5

5

5

Turn-on time

micro- seconds

100

100

100

100

100

100

Turn-off time

micro- seconds

750

750

750

750

750

750

Output voltage drop maximum peak

V

1.6

1.6

1.6

1.6

1.6

1.6

Nominal logic voltage

VDC

5

5

5

15

24

24

Logic voltage range

VDC

4–8

4–8

4–8

10.5–16

19.5–32

19.5–32

Logic pickup voltage

VDC

4

4

4

10.5

19.5

19.5

Logic dropout voltage

VDC

1

1

1

1

1

1

Logic input current at nominal logic voltage

mA

12

12

12

15

18

18

Temperature: Operating Storage

°C °C

-30 to +70 -30 to +85

-30 to +70 -30 to +85

-30 to +70 -30 to +85

-30 to +70 -30 to +85

-30 to +70 -30 to +85

-3- to +70 -30 to +85

Agency Approvals UL, CE, CSA; UKCA UL, CE, CSA; UKCA UL, CE, CSA; UKCA UL, CE, CSA; UKCA UL, CE, CSA; UKCA UL, CE, CSA; UKCA UL, CE, CSA; UKCA

* Compatible with Raspberry Pi. ** Part numbers ending in FM are Factory Mutual approved. *** Not for use with Opto 22 brains.

0254

G4 Digital DC Output Modules Data Sheet

Opto 22’s G4 DC output modules are used to control or switch DC loads.This document includes descriptions, specifications, and wiring and dimensional diagrams for Opto 22’s G4 DC output modules:

  • G4ODC5
  • G4ODC5A
  • G4ODC5MA
  • G4ODC15
  • G4ODC24
  • G4ODC24A

View

0727

G4 Digital I/O Data Book

The G4 Digital I/O Data Book provides complete details on every G4 digital I/O product component, including adapter cards, I/O modules, and mounting racks.

View

2375

UKCA Declaration of Conformity (EMC, LVD, RoHS)

This document is the Manufacturer's Declaration of Conformity for the products listed herein, in accordance with EMC, LVD, and RoHS rules, regulations and standards of the United Kingdom. The models cited have been tested to the essential requirements listed in the Standards section, and fully comply with the legislation as listed in UK Legislation section.

View

2285

Declaration of Conformity (EMC, LVD, RoHS)

This document is the Manufacturer's Declaration of Conformity for the products listed herein, in accordance with European, international, and/or national standards and regulations.

View

1648

Opto 22 RoHS 3 Statement of Compliance - Restriction of Hazardous Substances

This document is a statement of compliance with the EU Directive 2015/863/EU, Restriction of Hazardous Substances (RoHS 3). This document lists Opto 22 products that comply with the substance restrictions of the RoHS 3 directive.

View

1287

G4 Digital I/O Wiring Diagrams

Wiring diagrams for G4 modules and racks

View

1058

CSA Approval Document

This document lists all Opto 22 part numbers that have the Canadian Standards Association (CSA) approval.

View

1057

UL Approval Document

This document lists all Opto 22 part numbers that have the Underwriters Laboratory (UL) approval.

View

0892

CE Declaration: EMC

This document is the Manufacturer's Declaration for the listed products as mentioned in the attachment - to which this confirmation refers - that they are in accordance with Directive 2014/30/EU.

View

0891

CE Declaration: Low Voltage

This document is the Manufacturer's Declaration for the listed products as mentioned in the attachment - to which this confirmation refers - that they are in accordance with Directive 2014/35/EU.

View

CAD 3D Drawing: G4ODC Digital Output Modules

This CAD file contains a three-dimensional drawing of G4ODC digital DC output modules, part of the G4 I/O family. The drawing applies to the following modules: G4ODC15 G4ODC24 G4ODC24A G4ODC5 G4ODC5A

View No videos or demos are available for this product.

Từ khóa » G4 Odc24