G5V-1 DC3 | Micro Relay G5V-1 | OMRON | MISUMI Thailand

Micro Relay Specifications

G5V-1 external appearance

G5V-1 external appearance

G5V-1 dimensional outline drawing

G5V-1 dimensional outline drawing

PCB processing drawing

PCB processing drawing

Ratings (Operating Coil/Standard Type, Model G5V-1)

ItemsRated Current(mA)Coil Resistance(Ω)Operating Voltage(V)Release Voltage(V)Maximum Allowable Voltage(V)Power Consumption(mW)
Rated Voltage (V)
DC3506080% or Less10% or More200%(at 23°C)Approx. 150
530167
916.7540
1212.5960
246.253,840

Note 1: The rated current and coil resistance are measured at a coil temperature of +23°C and a tolerance of 10%. Note 2: The operating characteristics are measured at a coil temperature of +23°C. 3. The maximum allowable voltage is the maximum voltage that can be applied to a relay coil. 4. Model G5V-1-2 (with an operating voltage of 70% or less) is also available as part of a special product series.

Switching Part (Contact Part)

LoadResistance Load
Contact Touching MechanismSingle Crossbar Contact
Contact MaterialAu Alloy + Ag
Rated Load125 V AC 0.5 A, 24 V DC 1 A
Rated Conduction Current2 A
Maximum Contact Voltage Value125 V AC 60 V DC
Maximum Contact Current Value1 A

Performance

Contact Resistance *1100 mΩ or Less
Turn-ON Time5 ms or Less
Turn-OFF Time5 ms or Less
Insulation Resistance *21,000 MΩ or More
Withstand VoltageBetween Coil and Contact1,000 V AC 50/60 Hz 1 min
Between Contacts of Same Polarity400 V AC 50/60 Hz 1 min
VibrationDurability10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Malfunction10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Shock / ImpactDurability1,000 m/s2
Malfunction100 m/s2
DurabilityMechanical5,000,000 Times or More (Switching Frequency: 36,000 Times/h)
Electrical100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h)
Failure Rate P Level (Reference Value *3)5 V DC, 1 mA
Ambient Operating Temperature-40 to +70°C (Standard Type), -40 to +90°C (Model G5V-1-T90)(Assuming No Freezing or Condensation)
Operating Ambient Humidity5 to 85% RH
WeightApprox. 2 g

Note: The above values are the initial default values.*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.*2. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter between coil contacts and 250 V DC between contacts of the same polarity.*3. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 100 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.

Từ khóa » G5v-1-dc3