H05VVC4V5-K UL/CSA | PVC Control Cable With Copper Braiding ...
Có thể bạn quan tâm
Download PDF Data sheet
Item descriptions
| Application: | Suitable for dry, damp and wet locations but not in the open-air. It is used as a screened termination and connection cable in the control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies. Suitable as a signal and impulse cable for control and inspection of industrial plants, machinery and working processes. |
| Construction: | 1.....fine-stranded bare copper 2.....core insulation of special polyvinylchloride (PVC) 3.....inner sheath of special polyvinylchloride (PVC) 4.....braiding of tinned copper wires 5.....outer sheath of special polyvinylchloride (PVC), grey |
| Information: | 0,50 mm² is equivalent to app. AWG 20 ( 0,519mm²) 0,75 mm² is equivalent to app. AWG 18 ( 0,823mm²) 1,00 mm² is equivalent to app. AWG 17 ( 1,040mm²) 1,50 mm² is equivalent to app. AWG 15 ( 1,650mm²) 2,50 mm² is equivalent to app. AWG 13 ( 2,630mm²) |
| Standards: | DIN VDE 0281-13, HD 21.13.S1 UL/CSA (UL-Style 2587) DIN EN 60228 class 5 (construction) core identification: 1 core green/yellow, other cores black with figures |
| Nominal voltage Uo/U | [V] | 600 Volt | |
| Test voltage | [V]AC | 3000 | |
| Temperature range | in motion | -5°C till +90°C | |
| fixed | -40°C till +90°C | ||
| Operating temperature | short circuit | °C | 150 |
| Short circuit time | max. | [sec] | 5 |
| Bending radius | one time / fixed | x diameter | 12,5 |
| in motion | x diameter | 15,0 | |
| Oil-resistant | standard | EN 60811-2-1 | |
| Flammability | standard | EN 60332-1-2 | |
| Insulation resistance | min. | [MOhm/km] | 20 |
| Number of cores and nominal cross section mm² | Copper figure kg/km | Cond. construction (appr. value) mm | Overall diameter mm | Weight appr. kg / km |
| 3 G 0,75 | 50,88 | 24 x 0,21 | 8,8 | 125 |
| 4 G 0,75 | 63,36 | 24 x 0,21 | 9,6 | 147 |
| 5 G 0,75 | 78,72 | 24 x 0,21 | 10,3 | 172 |
| Number of cores and nominal cross section mm² | Copper figure kg/km | Cond. construction (appr. value) mm | Overall diameter mm | Weight appr. kg / km |
| 7 G 0,75 | 107,52 | 24 x 0,21 | 12,2 | 235 |
| 12 G 0,75 | 161,28 | 24 x 0,21 | 14,5 | 354 |
| 18 G 0,75 | 219,84 | 24 x 0,21 | 16,9 | 478 |
| 3 G 1 | 74,88 | 32 x 0,21 | 9,3 | 140 |
| 4 G 1 | 86,40 | 32 x 0,21 | 9,9 | 165 |
| 5 G 1 | 101,76 | 32 x 0,21 | 10,9 | 195 |
| 7 G 1 | 126,72 | 32 x 0,21 | 12,9 | 271 |
| 12 G 1 | 193,92 | 32 x 0,21 | 15,4 | 405 |
| 18 G 1 | 264,96 | 32 x 0,21 | 17,7 | 548 |
| 3 G 1,5 | 95,04 | 30 x 0,26 | 10,4 | 180 |
| 4 G 1,5 | 116,16 | 30 x 0,26 | 11,3 | 217 |
| 5 G 1,5 | 129,60 | 30 x 0,26 | 12,6 | 267 |
| 7 G 1,5 | 168,00 | 30 x 0,26 | 14,9 | 379 |
| 12 G 1,5 | 254,40 | 30 x 0,26 | 17,6 | 538 |
| 18 G 1,5 | 384,00 | 30 x 0,26 | 20,5 | 743 |
| 3 G 2,5 | 147,84 | 50 x 0,26 | 12,0 | 246 |
| 4 G 2,5 | 163,20 | 50 x 0,26 | 13,3 | 316 |
| 5 G 2,5 | 199,68 | 50 x 0,26 | 14,6 | 383 |
Download PDF Data sheet
Send an inquiry regarding this product and our sales representative will contact you as soon as possible with detailed information.A quick and simple solution for obtaining price and delivery information!Fill in the contact form
Polje "Ime" ne smije biti prazno. Polje "E-mail" nije ispravno. Polje sa Vašom porukom ne smije biti prazno. Neispravno unijeto captcha polje. Poruka je poslana Nažalost došlo je do greške kod slanja. Pokušajte ponovno. Error.CHOOSE AN ITEM GROUP
- PVC Insulated Wires
- PVC Sheathed Cables
- Rubber Insulated and Sheathed Cables
- Power Cables 0,6/1 KV PVC and PE Insulated
- Power Cables 6 - 30 KV PVC and XLPE Insulated
- Cables for Cranes and Hoists
- Building Site Cables
- PVC Control Cables
- Chain Cables, Servo and Composite Cables
- Heat Resistant Cables and Silicone Cables
- Halogen-Free Cables and Wires
- Fire Alarm Cables
- Telecommunication Cables
- Coaxial Cables
- Electronic and Computer Cables, LAN Cables, Optical Fibre Cables
- Compensating and Thermal Cables
View what's on offer...
-
(N)YFAZ | PVC Twin Wire
MORE INFO -
LSP | Loudspeaker Wire
MORE INFO -
RG 58 C/U | Coaxial Cable 50 Ohm
MORE INFO -
ASI-BUS | Field-Bus ASI
MORE INFO in TOP
Tesla kabeli d.o.o. Industrijska 20, 10431 Sveta Nedelja, Hrvatska
OIB: 75321357467 MB: 4081340
OTP banka d.d. - Split HR6524070001100185687 | SWIFT OTPVHR2XHrvatska poštanska banka d.d. - Zagreb: HR2823900011198007664 | SWIFT HPBZHR2XKentBank d.d. – Zagreb HR5341240031199011634 | SWIFT KENBHR22Erste&Steiermärkische Bank d.d. - Zagreb HR5024020061100674424 | SWIFT ESBCHR22
Tesla kabeli d.o.o. Batajnički drum 10. deo br. 1, 11080 Zemun, Srbija
PDV: RS108828595PIB: 108828595MB: 21075680
AIK banka A.D. - Beograd RS35105000000280701248 | SWIFT AIKBRS22OTP banka - Srbija A.D. Novi Sad RS35325960170006817238/ SWIFT: OTPVRS22ERSTE BANK - A.D. Novi Sad RS35340000001101229969 / SWIFT: GIBARS22
[email protected]Từ khóa » H05vvc4v5-k
-
H05VVC4V5-K - PVC Control Cable With Copper Braiding, Oil ...
-
H05VVC4V5-K Cable - Eland Cables
-
H05VVC4V5-K | Prysmian Group
-
H05VVC4V5-K
-
ölflex® 140 Cy - Catalogue - Lapp Group
-
H05VVC4V5-K NYSLYCYÖ - ören Cables
-
H05VVC4V5-K Multinorm - Kabeltec
-
H05VVC4V5-K (NYSLCYO-J) - Kabeltec
-
H05VVC4V5-K 2x0,75 PVC Control Cable Oil Restistant, Grey
-
Control Cable: H05VVC4V5-K (NYSLYCY�-JZ) - Hi-Tech Controls
-
H05VVC4V5-K Steuerleitung, Geschirmt | 300/500 V - SAB Bröckskes
-
H05VVC4V5-K Von Faber
-
[PDF] H05VVC4V5-K Cu-screened DIN VDE - HAR Approved