Language English Español SOLUTION Service News +86-(0)371-60306197 [email protected] tanocable +86-13523507083 Home Products Bare Conductor Overhead Insulated Cable Power Cable Concentric Cable Building Wire Rubber Cable OPGW Cable Other Cables About us Who We Are Why choose us FAQ Contact us Get A Quote
Home Products Bare Conductor Overhead Insulated Cable Power Cable Concentric Cable Building Wire Rubber Cable OPGW Cable Other Cables About us Who We Are Why choose us FAQ SOLUTION Service News Contact us Tel: +86-(0)371-60306197 E-mail: [email protected] Skype: tanocable Whatsapp: +86-13523507083 Follow Us: Language English Español Home Products > Building Wire
H07V-U & H07V-R & H07V-K Play product video Inquire Now Overview Specifications CONSTRUCTION PARAMETER Overview APPLICATION Installation in surface mounted or embedded conduits, or similar closed systems. Suitable for fixed protected installation in, or on, lighting or controlgear for voltages up to 1000V a.c. or, up to 750V d.c. to earth. STANDARD BS EN 50525-2-31 DOWNLOAD CABLE DATASHEET
BS EN 50525-2-31
ELECTRICAL PANEL WIRING HOME USE INDUSTRIAL USE COMMERCIAL USE
BY COLOR Specifications
STANDARD BS EN 50525-2-31
APPLICATION ELECTRICAL PANEL WIRING HOME USE INDUSTRIAL USE COMMERCIAL USE
CORE IDENTIFICATION BY COLOR
APPROVALS CE
INSTALLATION CONDITIONS IN CONDUIT
CABLE MARKING OIL INK PRINTING EMBOSSING PRINTING
PACKAGING BY COIL/BY ROLL BY PLASTIC, POLYWOOD, WOODEN REEL/DRUM
CONSTRUCTION 1. Conductor: Annealed copper conductor acc. to EN 60228: class 1 solid -H07V-U class 2 stranded H07V-R class 5 flexible H07V-K 2. Insulation: PVC compound type TI 1 3. Color of insulation: Blue, black, brown, green/yellow or other colors
CHARACTERISTIC Maximum conductor operating temperature: +70°C Lowest ambient temperature for fixed installation: -30°C Lowest installation temperature: -5°C Maximum short-circuit conductor temperature: +160°C Nominal voltage:Uo/U: 450/ 750 V Test voltage: 2500V Flame retardant: IEC 60332-1-2 Minimum bending radius: | Minimum bending radius: | For cable diameter D (mm) | |||
| D≤8 | 8<D≤12 | 12<D≤20 | D>20 | |
| Normal use | 4 D | 5 D | 6 D | 6 D |
| Careful bending at termination | 2 D | 3 D | 4 D | 4 D |
| Nominal Cross Section Area | No. of Wires /Dia. of Wires | Approx. Dia. of Conductor | Thickness of Insulation | Approx. Overall Dia. | Approx. Weight of Cable | Max. Conductor Resistance at 20°C | Min. Insulation Resistance at 70°C |
| mm2 | No./mm | mm | mm | mm | kg/km | Ω/km | MΩ.km |
| H07V-U | |||||||
| 1.5 | 1/1.38 | 1.38 | 0.7 | 2.9 | 20.9 | 12.1 | 0.011 |
| 2.5 | 1/1.78 | 1.78 | 0.8 | 3.5 | 32.8 | 7.41 | 0.010 |
| 4 | 1/2.25 | 2.25 | 0.8 | 4.0 | 47.9 | 4.61 | 0.0087 |
| 6 | 1/2.76 | 2.76 | 0.8 | 4.5 | 67.8 | 3.08 | 0.0074 |
| 10 | 1/3.57 | 3.57 | 1.0 | 5.7 | 112.0 | 1.83 | 0.0072 |
| Nominal Cross Section Area | No. of Wires /Dia. of Wires | Approx. Dia. of Conductor | Thickness of Insulation | Approx. Overall Dia. | Approx. Weight of Cable | Max. Conductor Resistance at 20°C | Min. Insulation Resistance at 70°C |
| mm2 | No./mm | mm | mm | mm | kg/km | Ω/km | MΩ.km |
| H07V-R | |||||||
| 1.5 | 7/0.52 | 1.56 | 0.7 | 2.96 | 21.5 | 12.1 | 0.010 |
| 2.5 | 7/0.68 | 2.04 | 0.8 | 3.64 | 34.6 | 7.41 | 0.0099 |
| 4 | 7/0.85 | 2.55 | 0.8 | 4.15 | 49.5 | 4.61 | 0.0082 |
| 6 | 7/1.04 | 3.12 | 0.8 | 4.72 | 69.5 | 3.08 | 0.0070 |
| 10 | 7/1.35 | 4.05 | 1.0 | 6.05 | 116.3 | 1.83 | 0.0067 |
| 16 | 7/1.70 | 5.1 | 1.0 | 7.1 | 167.1 | 1.15 | 0.0056 |
| 25 | 7/2.14 | 6.42 | 1.2 | 8.82 | 268.8 | 0.727 | 0.0053 |
| 35 | 7/2.52 | 7.56 | 1.2 | 9.96 | 364.6 | 0.524 | 0.0046 |
| 50 | 19/1.78 | 8.90 | 1.4 | 11.7 | 517.7 | 0.387 | 0.0046 |
| 70 | 19/2.14 | 10.70 | 1.4 | 13.5 | 708.2 | 0.268 | 0.0040 |
| 95 | 19/2.52 | 12.60 | 1.6 | 15.8 | 959.7 | 0.193 | 0.0039 |
| 120 | 37/2.03 | 14.21 | 1.6 | 17.41 | 1194.8 | 0.153 | 0.0035 |
| 150 | 37/2.25 | 15.75 | 1.8 | 19.35 | 1493.4 | 0.124 | 0.0035 |
| 185 | 37/2.52 | 17.64 | 2.0 | 21.64 | 1843.5 | 0.0991 | 0.0035 |
| 240 | 61/2.25 | 20.25 | 2.2 | 24.65 | 2383.5 | 0.0754 | 0.0034 |
| 300 | 61/2.52 | 22.68 | 2.4 | 27.48 | 2971.5 | 0.0601 | 0.0033 |
| 400 | 61/2.85 | 25.65 | 2.6 | 30.85 | 3927.4 | 0.0470 | 0.0031 |
| Nominal Cross Section Area | No. of Wires /Dia. of Wires | Approx. Dia. of Conductor | Thickness of Insulation | Approx. Overall Dia. | Approx. Weight of Cable | Max. Conductor Resistance at 20°C | Min. Insulation Resistance at 70°C |
| mm2 | No./mm | mm | mm | mm | kg/km | Ω/km | MΩ.km |
| H07V-K | |||||||
| 1.5 | 30/0.25 | 1.57 | 0.7 | 2.97 | 21.2 | 13.3 | 0.010 |
| 2.5 | 49/0.25 | 2.02 | 0.8 | 3.62 | 33.4 | 7.98 | 0.0095 |
| 4 | 56/0.30 | 2.9 | 0.8 | 4.5 | 50.3 | 4.95 | 0.0078 |
| 6 | 84/0.30 | 3.6 | 0.8 | 5.2 | 71.1 | 3.30 | 0.0068 |
| 10 | 84/0.40 | 4.7 | 1.0 | 6.7 | 117.7 | 1.91 | 0.0065 |
| 16 | 126/0.40 | 5.9 | 1.0 | 7.9 | 177.7 | 1.21 | 0.0053 |
| 25 | 196/0.40 | 7.3 | 1.2 | 9.7 | 275.0 | 0.780 | 0.0050 |
| 35 | 276/0.40 | 9.2 | 1.2 | 11.6 | 376.1 | 0.554 | 0.0043 |
| 50 | 396/0.40 | 11 | 1.4 | 13.8 | 535.0 | 0.386 | 0.0042 |
| 70 | 360/0.50 | 13.1 | 1.4 | 15.9 | 730.0 | 0.272 | 0.0036 |
| 95 | 475/0.50 | 14.4 | 1.6 | 17.6 | 981.3 | 0.206 | 0.0036 |
| 120 | 608/0.50 | 16.3 | 1.6 | 19.5 | 1221.8 | 0.161 | 0.0032 |
| 150 | 756/0.50 | 18.7 | 1.8 | 22.3 | 1532.5 | 0.129 | 0.0032 |
| 185 | 925/0.50 | 20.1 | 2.0 | 24.1 | 1883.8 | 0.106 | 0.0032 |
| 240 | 1221/0.50 | 23.1 | 2.2 | 27.5 | 2435.9 | 0.0801 | 0.0031 |
TW/THW Type TW and THW may be used for general purpose wiring for power and lighting, for installation in air, conduit, duct or other recognized raceways, in wet or dry locations. Learn more
6242Y FLAT TWIN & EARTH Fixed installation in dry or damp premises on walls, boards or trays, in channels or embedded in plaster Learn more
FLAT TPS CABLE It is used in conduit, underground ducts for domestic, commercial and industrial installations where not subject to mechanical damage. Learn more
H05V-U & H05V-R & H05V-K PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Learn more
H05VV-F Flexible cables for mobile lightweight, suitable for installation in homes, kitchens, offices, for connection of portable light as hair dryers, washing machines, refrigerators etc.. Learn more
THHN/THWN General use in commercial and industrial construction, and installations where resistance against oils and gasoline is required. Learn more
TSJ/TSJ-N CABLE It is manufactured in duplex, triplex and quadruplex formations, in gauges ranging from 18 AWG (0.824 mm2) to 6 AWG (13.3 mm2). Learn more Inquiry We respond quickly to any questions, inquiries, needs and feedback. If you have business needs or questions about our products, feel free to contact us. Your Country Company name Your name * Email * Phone * Skype/WhatsApp/Wechat Your message * Submit If you have any question, please do not hesitate to contact us. We will do our best to help and support. [email protected] +86-(0)371-60306197 tanocable +86-13523507083 CONTACT US
Copyright © 2020 Henan Tano Cable Co., Ltd. All rights reserved.
Từ khóa » H07v-r Vs H07v-k
-
H07V-U . H07V-R . H07V-K - Fast Cables
-
H07V-U,H07V-R,H07V-K,450/750V Copper Conductor PVC ...
-
[PDF] PVC-insulated Wires H07VU/- R/-K Acc. To EN 50525-2-31
-
450/750V H07V-U/ H07V-R / H07V-K PVC Insulated Cable
-
Low Voltage Wire Up To 750 Volt; H07V-K, H07V-R, H07V-U - Seen Joo
-
[PDF] H07V-U H07V-R H07V-K 450/750V
-
H07V-K And H05V-K Cables | Allied University
-
What Do The Letters Stand For In VDE Cable And The Corresponding ...
-
H07V-U, H07V-R, H07V-K, 450/750V Copper Conductor PVC ...
-
H07V-U H07V-R H07V-K Building Wire Single Core Non-Sheathed
-
H07V-R ( Ym ) - PVC Insulated Single Core Wire - Allkabel Sro
-
Cable H05V-U, H05V-R, H05V-K, H07V-U, H07V-R, H07V-K
-
H07V-R | Everwell Cables & ElectricalEverwell Cables & Electrical