H07Z-K - Cables RCT

Có thể bạn quan tâm

  1. You are here:  
  2. Cables RCT
  3. Products
  4. Product range by material
  5. HFFR Cables
  6. 450/750 V
  7. H07Z-K
HFFR Cables
H07Z-K
Featured

H07Z-K

These halogen free cables comply with the construction product classification criteria according to the EU CPR Regulation 305/2011 and EN 50575 , being those suitable for setting up wiring installations for panels, especially when a low fume and corrosive gas emission and improved behaviour with temperature is required.

Reference Standards

UNE-EN 50525-3-41, EN 50525-3-41, IEC 60227-3

Applications

Suitable for the following installations:

  • Meter centralization
  • Premises with public attendance
Industrial90 GradosAlta SeguridadFlexibleAENORHARROHSCPR

Technical Characteristics

Imagen construcción H07Z-K
1.Conductor

Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228

2.Insulation

Thermosetting material with polyolefin base with low fume and corrosive gas emission, type EI-5,in accordance with UNE 21027-9 and HD 22.9S3:2007

Nominal voltage

450/750 V

Test voltage

2.500 V A.C.

Maximum temperature

90 ºC

Minimum temperature

-15ºC According to standard cold tests

Colors

According to UNE-EN 50525-1 and EN 50525-1

No flame spread

According to UNE-EN 60332-1-2, EN 60332-1-2 and IEC 60332-1-2

Low halogen content

According to IEC 60754-1 and 60754-2

Low emission of corrosive gases

According to UNE-EN 50267, EN 50267 and IEC 60754-1 and 60754-2

Low emission of opaque fumes

According to UNE-EN 61034-2, EN 61034-2 and IEC 61034-2

Dimensions

Section (mm2)Resistance at 20°C (Ohm/km)External Diameter (mm)Weight (kg/km)Class

1x1,5

13,3

2,90

18

Dca-s2,d2,a2

1x2,5

7,98

3,48

28

Dca-s2,d2,a2

1x4

4,95

4,00

42

Dca-s2,d2,a2

1x6

3,3

4,48

60

Dca-s2,d2,a2

1x10

1,91

5,90

104

Dca-s2,d2,a2

1x16

1,21

6,85

154

Dca-s2,d2,a2

1x25

0,78

8,47

231

Dca-s2,d2,a2

1x35

0,554

9,80

322

Dca-s2,d2,a2

1x50

0,386

11,60

464

Dca-s2,d2,a2

1x70

0,272

13,45

653

Dca-s2,d2,a2

1x95

0,206

16,00

856

Dca-s2,d2,a2

1x120

0,161

17,80

1106

1x150

0,129

19,60

1360

1x185

0,106

21,56

1628

1x240

0,0801

24,12

2145

Documents

Data SheetDeclaration of PerformanceAENOR CertificateHAR Certificate
VersionFrom Until
041-0213/09/17
041-0127/07/1713/09/17

Say hello!

Contact
Cables RCT Fábrica

Pol Ind. PridesCtra Castellón km 226.950720 La Cartuja BajaZaragoza - Spain

Tel.: +34 976 500 120Mail: [email protected]

Cables RCT Depósito Barcelona

Pol. Ind. MonsolísAvinguda del Bon Pastor 19-2708930 San Adrià de Besòs - Spain

Tel.: +34 93 3079562Mail: [email protected]

Cables RCT Depósito Madrid

Área Empresarial AndalucíaAvda. Río Guadalquivir, 728906 Getafe - Madrid - Spain

Tel.: +34 91 6918548Mail: [email protected]

Cables RCT Depósito Sevilla

Polígono Industrial Calongec/ Bronce Nave 441007 Sevilla - Spain

Tel.: +34 954 354946Mail: [email protected]

Cables RCT Depósito Valencia

Polígono Industrial Sedavíc/ Sequía de Calvera 5 A46910 Valencia - Spain

Tel.: +34 96 3759070Mail: [email protected]

  • Privacy Policy
  • Disclaimer and Conditions of Use
  • Cookies Policy
  • Inicio

Tlf.(+34) 976 500 120

  • Facebook
  • Twiter
  • Youtube
  • Likedin
  • Products
    • Product range by material
      • PVC Cables
        • Cables 300/300 V
        • Cables 300/500 V
        • Cables 450/750V
        • Cables 0.6/1 KV
        • Instrumentation and control
      • HFFR Cables
        • Cables 300/500 V
        • Cables 450/750 V
        • Cables 0.6/1 KV
        • Instrumentation and control
      • UL certified cables
      • Solar cables
      • Shielded cables
      • Bare copper
      • Prewired cable
      • Automotive Cables
      • Inkjet cables (Marking Grade)
  • Products
    • Product range by voltage
      • 300/300 V
      • 300/500 V
      • 450/750 V
      • 0.6/1 kV
      • UL certified cables
      • 1,5/1,5 kV dc
      • Instrumentation and control
      • Bare copper
      • Automotive cables
      • InkJet cables (Marking Grade)
      • Prewired cable
  • Products
    • Packaging
      • Reel Sizes
      • Plywood Reels
      • Boxed Wire®
      • Plastic reels
      • Cardboard Reels
      • Shrink-plastic packaging
  • RCT Cables - We are manufacturers
  • Blog
  • Copper Price
  • CPR Regulation
    • 1: What is the CPR? Who does it affect?
    • 2: What characteristics must the cables satisfy with respect to the CPR?
    • 3: Since when must the CPR be applied to cables?
    • 4: Which are the Euroclasses of the CPR that apply to cables?
    • 5: What does the Euroclass initial mean?
    • 6: Euroclass classification
    • 7: How are cables assessed and verified externally?
    • 8: What is the declaration of performance “DoP”?
    • 9: What does the EC marking look like?
  • Downloads
    • Company certificates
    • Technical documents
    • Data Sheet - Certificates
    • Logos
  • Contact Us
    • Headquarters
    • Delegation Barcelona
    • Delegation Madrid
    • Delegation Sevilla
    • Delegation Valencia

Select your language

English
  • Español
  • Français
  • Português
  • English
  • Facebook
  • Twiter
  • Youtube
  • Likedin

Từ khóa » H07z