 | | *E-mail | | *Name | | *Company | | *Phone | | *State | | *Zip Code | | *Country | | Please answer the security question: 3+2= | | (*) Required Fields | | | | 303-699-1135 1-800-456-9012 |  | - Cable & Wire
All-weather, Rubber & Welding - All-weather Cable
- Rubber & Welding Cable
Coaxial, Video & Loudspeaker - RG-Coaxial Cable
- Halogen-free RG-Coaxial Cable
- CATV-Cable
- SAT-Coaxial Cable to 2150 MHz
- Multimedia Coaxial Cable
- SAT-Coaxial Cable (Digital TV)
- Video Cable
- RGB-Transmission Cable
- Loudspeaker Cable
-
Control Cables - PUR Control Cable, Unshielded
- PUR Control Cable, Shielded
- PUR Track Cable, Unshielded
- PUR Track Cable, Shielded
- PVC Control Cable, Unshielded
- PVC Control Cable, Shielded
- PVC Track Cable, Unshielded
- PVC Track Cable, Shielded
- Bio Oil Resistant Cable
- Halogen-free Control Cable
- Safety Against High Bending - Track Cable
- Intrinsically Safe PVC Cable
Data & Computer Cables - Flexible PVC Cable
- Highly Flexible PVC Cable
Data, Network & BUS - Helucom® Fiber Optics Cable
- Helukat® Copper Data Cable
- European BUS Cable
Flat & Ribbon Cables - Flat Cables & Ribbon Cables in PVC
Halogen-free Security Cables -
Introduction -
Halogen-free Installation Cable -
Halogen-free Control Cable -
Halogen-free Data Cable -
Harmonized Cable - Harmonized Cable, VDE, UL, CSA approved
Heat-Resistant & Compensating - Silicone Cable
- Fluorinated Polymeric Cable
- Single Conductor
- Multi Conductor
- Compensating Cable
Installation Cables - Installation Cables, Halogen-free
Internationally Approved - Multi-Approval Cables: UL, CSA, CE, Hookup Wire
Media Cables - Media Cables, Audio, Video, Speaker, Audio & Light
Power Cables, Medium Voltage - Power / Underground Cable & Ground Conductor
- Gas Station Cable
- Introduction: XLPE-insulated Power Cable
- Power Cables up to 30 kV, XLPE-insulated
Pre-assembled Cables - Pre-assembled Cables & Wires
Servo, Feedback & Motor Cable - Feedback Cable
- Servo Cable
- Motor Cable
- Sensor/Actuator Cable
- Robotics Cable
- Track Cable
Tray Rated Control Cables Single Conductors - PVC Single Conductor (-5°C up to +80°C)
Special Cables - Special PVC/PUR Control Cable
- Single Conductors
- Trailing Cable
- Cable for Renewable Energy
- Sensor/Actuator Cable
- Airport 400 Hz
- Truck Cable
Spiral Cable - Spiral Cables, PVC or PUR
Telephone & Fire Warning Cables - Telephone Cables & Fire Warning Cables, VDE approved
Vehicle Cables - Vehicle Cables acc. to DIN ISO 6722
- Advertising & Media
- Catalogs
- Cable & Wire
- Industrial Enclosures
- Strain Relief Fittings
- Circular Connectors
- Conduit
- Pneumatics
- Accessories
- Flyers
- Cable & Wire
- Industrial Enclosures
- Strain Relief Fittings
- Circular Connectors
- Conduit
- Pneumatics
- Accessories
- Blog
| | | | | Cable Index | Halogen-Free Security Cable | Halogen-Free Installation Cable |  | Printable PDF | | | Halogen-Free Security Cable: J-H(St)H | | Bd Installation Cable, Halogen-Free, According to VDE 0816 | Sealcon, Inc, European & Domestic cable H.jpg) | | Part-No. | Description & No. of pairs x diameter in mm | Outer Diameter mm | Copper Weight kg/km | Weight ca. kg/km | AWG | | 34050 | J-H(ST)H 2X2X0.6 | 5.8 | 14.0 | 50.0 | - | | 34051 | J-H(ST)H 4X2X0.6 | 8.6 | 25.0 | 91.0 | - | | 34052 | J-H(ST)H 6X2X0.6 | 9.0 | 37.0 | 100.0 | - | | 34053 | J-H(ST)H 10X2X0.6 | 10.3 | 59.0 | 147.0 | - | | 34054 | J-H(ST)H 20X2X0.6 | 15.5 | 116.0 | 308.0 | - | | 34055 | J-H(ST)H 30X2X0.6 | 16.5 | 172.0 | 350.0 | - | | 34056 | J-H(ST)H 40X2X0.6 | 18.6 | 229.0 | 465.0 | - | | 34057 | J-H(ST)H 50X2X0.6 | 20.7 | 286.0 | 571.0 | - | | 34058 | J-H(ST)H 60X2X0.6 | 22.8 | 342.0 | 662.0 | - | | 34059 | J-H(ST)H 80X2X0.6 | 26.6 | 455.0 | 877.0 | - | | 34060 | J-H(ST)H 100X2X0.6 | 28.2 | 568.0 | 1055.0 | - | | 34061 | J-H(ST)H 2X2X0.8 | 6.8 | 25.0 | 70.0 | - | | 34062 | J-H(ST)H 4X2X0.8 | 10.5 | 45.0 | 135.0 | - | | 34063 | J-H(ST)H 6X2X0.8 | 10.9 | 65.0 | 151.0 | - | | 34064 | J-H(ST)H 10X2X0.8 | 13.1 | 106.0 | 230.0 | - | | 34065 | J-H(ST)H 20X2X0.8 | 20.4 | 206.0 | 507.0 | - | | 34066 | J-H(ST)H 30X2X0.8 | 21.5 | 307.0 | 600.0 | - | | 34067 | J-H(ST)H 40X2X0.8 | 24.5 | 407.0 | 788.0 | - | | 34068 | J-H(ST)H 50X2X0.8 | 27.1 | 508.0 | 972.0 | - | | 34069 | J-H(ST)H 60X2X0.8 | 29.4 | 608.0 | 1120.0 | - | | 34070 | J-H(ST)H 80X2X0.8 | 33.2 | 809.0 | 1475.0 | - | | 34071 | J-H(ST)H 100X2X0.8 | 37.2 | 1010.0 | 1804.0 | - | | | - Flame retardant, halogen-free installation cable to DIN VDE 0815
- Temperature Range Flexing -5°C to +50°C (+23°F to +122°F) Fixed Installation -30°C to +70°C (-22°F to +158°F)
- Loop Resistance at +20°C/+68°F Max. 130 Ohm/km at 0.6 mm² Max. 73.2 Ohm/km at 0.8 mm²
- Operating Top Level Voltage 300 V (Not for purposes of high current and power installation)
- Test Voltage Conductor/conductor U eff. 800 V Conductor/shield 800 V
- Insulation Resistance Min. 100 MOhm x km
| - Mutual Capacitance at 800 Hz Max. 120¹) nF/km
- Capacitance Unbalances at 800 Hz K1 max. 300²) pF/100 m K9-K12 max. 100³) pF/100 m
- Line Attenuation at 800 Hz Approx. 1.5 dB/km
- Minimum Bending Radius During delivery 7.5 x cable Ø Single bending without tension = 2.5 x cable Ø Repeated bending under tension = 7.5 x cable Ø
- Radiation Resistance Up to 100x106 cJ/kg (up to 100 Mrad)
- Caloric Load Values See technical information
| - 1) This value may be extended by 20% with make-up to 4 pairs
- 2) 20% of the values, but one value up to 500 pF is allowed
- 3) 10% of the values, but four values (relationship) of up to 300 pF are allowed
| | | - Bare copper conductor, solid, 0.6 mm Ø and 0.8 mm Ø
- Conductor insulation of halogen-free compound type HI2, to DIN VDE 0207 part 23 insulation wall thickness 0.3 or 0.4 mm
- Conductor and star-quad identification to DIN VDE 0815
- Conductors twisted in quads
- The conductors to quads and the quads are stranded to units
- Conductor wrapping with plastic tape
- Drain wire solid
- Electrostatic shield (St) of plastic coated aluminum foil
- Halogen-free outer jacket type HM2 to DIN VDE 0207 part 24
- Jacket color: Gray
| The halogen-free installation cables with improved characteristics in the case of fire are used for the telephone transmission, measurement and control technology. The static shield protects the transmission circuits against outer electrical interferences. A fire propagation is prevented through high oxygen index of the insulation material and produce no corrosive gases in case of fire. Those cables are preferably used for telecommunication indoor installations and in special cases the outdoor installation is permitted under protection against sunlight. These cables are suitable for fixed installation in areas with danger of fire, in dry and damp environments as well as on, in and under plaster. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. | | | | - Not for purposes of high current and power installation as well as underground laying
- The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests - Flame test to DIN VDE 0482 part 266-2, BS 4066 part 3 / DIN EN 50266-2 / IEC 60332-3 (equivalent DIN VDE 0472 part 804 test method C)
- Corrosiveness of combustion gases according to VDE 0482 part 267 / DIN EN 50267-2-2 / IEC 60754-2 (equivalent DIN VDE 0472 part 813)
- Smoke density according to DIN VDE 0482 part 1034-1+2 / IEC 61034-1+2 / DIN EN 61034-1+2 / BS 7622 part 1+2 (equivalent DIN VDE 0472 part 816)
| | - 1) This value may be extended by 20% with make-up to 4 pairs
- 2) 20% of the values, but one value up to 500 pF is allowed
- 3) 10% of the values, but four values (relationship) of up to 300 pF are allowed
- LS0H = Low Smoke Zero Halogen-Free
| | | Items For Quote Update Easy Quote | Halogen-Free Installation Cables | | J-H(St)H | | J-2Y(St)H | | J-H(St)H (Fire Warning) | | JE-H(St)H | | JE-LiHCH | | JE-H(St)H (Fire Warning) | | JE-H(St)HRH | | N2XH | | N2XCH | | N2XH-FE 180/E 30 | | N2XCH-FE 180/E 30 | | NHXH-FE 180/E 30 | | NHXCH-FE 180/E 30 | | N2XH-FE 180/E 90 | | N2XCH-FE 180/ E 90 | | NHXH-FE 180/E 90 | | NHXCH-FE 180/E 90 | | H05Z-K / H07Z-K | | PUR Single Conductor | | Technical Information | | What are Halogens? | | Applications | | Advantages | | Caloric load values & regulations | | Tests: Behavior in fire Method A (on single cable) Method B (on single cable) Method C (on bunched cable) | | Corrosivity of combustion gases | | Continuance of insulation effect under direct fire conditions | | Smoke density | | Functionality of electric cable systems | | Test: Functionality under fire |  | | | is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry. | | |