HAMEG HM8012 USER MANUAL Pdf Download - ManualsLib
× Bookmark added × Added to my manuals
Print
Print page 1 Print document (15 pages)
- Manuals
- Brands
- Hameg Manuals
- Multimeter
- HM 8012
- User manual
- Manual (68 pages) ,
- Service manual (29 pages) ,
- Manual (68 pages)
- page of 15 Go / 15
- Contents
- Table of Contents
- Bookmarks
- Specifications
- Important Hints
- Operating Conditions
- Warranty and Repair
- Maintenance
- Operation of the Module
- Control Elements
- AC Voltage Measurement
- Current Measurement
- Resistance Measurements
- Protection against Overloads
- Crest Factor
- Diode Test
- Temperature Measurements
- Decibel Measurements
- Remote Control
- Function Commands
- Mode Commands
- Status Commands
- Function Test
- Measurement Equipment Used
- Wdm8012 Software
Quick Links
Download this manual See also: Service Manual, Manual Visit us at www.TestEquipmentDepot.com WDM8012 Software (incl. delivery) HZ15 PVC Test Leads Mainframe HM8001-2 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 4 ¾ - D i g i t p r o g r a m m a b l e M u l t i m e t e r H M 8 0 1 2 4¾ digit display with 50,000 counts Basic accuracy 0.05% Automatic and manual range selection Max. resolution 10μV, 0.01dBm, 10nA, 10m , 0.1°C/°F Offset function/relative value measurement in basicmeasurement functions Input impedance ›1G (0.5V and 5V DC range) RS-232 interface PC software for control and data logging Mainframe HM8001-2 required for operation inklusive Table of Contents Previous Page Next Page- 1
- 2
- 3
- 4
- 5
Need help?
Do you have a question about the HM8012 and is the answer not in the manual?
Ask a questionQuestions and answers
Related Manuals for Hameg HM8012
-
Multimeter Hameg HM8012 Manual 4 3/4 - digit multimeter (68 pages) -
Multimeter Hameg HM8012 Manual 4 3/4-digit multimeter (68 pages) -
Multimeter Hameg HM 8012 Manual (36 pages)
-
Multimeter Hameg HM 8012 Manual 4 3/4 digit programmable multimeter (35 pages)
-
Multimeter Hameg HM8012 Service Manual 4 3/4 digit multimeter (29 pages) -
Multimeter Hameg hmc8012 User Manual (47 pages)
-
Multimeter Hameg HMC8012 Programmer's Manual Scpi commands (72 pages)
-
Multimeter Hameg HM8011-3 Operating Manual Hm8011-3 (33 pages) -
Multimeter Hameg HM8011-3 Service Manual (9 pages) -
Multimeter Hameg HM8112-3 Manual 6 1/2-digit precision-multimeter (56 pages)
-
Multimeter Hameg HM 8040-2 Manual (27 pages)
-
Multimeter Hameg HM8112-3S Manual 6 1/2 digit precision multimeter (56 pages) -
Multimeter Hameg HM8010 Manual 4 3/4 - digit multimeter (60 pages) -
Multimeter Hameg HM8112-2 Manual Programmable multimeter (27 pages)
Summary of Contents for Hameg HM8012
- Page 1 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com 4 ¾ - D i g i t p r o g r a m m a b l e M u l t i m e t e r H M 8 0 1 2 WDM8012 Software 4¾...
-
Page 2: Specifications
≥ 60 dB (50/60 Hz ± 0.5%) CMRR fs. = full scale; Crest factor: 7 max. Included in delivery: HM8012 Multimeter, Manu- AC current al, HZ14 Interface cable, HZ15 PVC Test Leads, Measurement ranges: 500 μA, 5 mA, 50 mA, 500 mA, 10 A Software-CD. -
Page 3: Important Hints
International Electrotechnical Commission Warranty and Repair (IEC) safety standards. HAMEG instruments are subjected to a strict qua- Warning! lity control. Prior to leaving the factory, each ins- Any interruption of the protective conductor trument is burnt-in for 10 hours. -
Page 4: Maintenance
RMA number either by internet (http://www. instrument is not connected to the protective earth hameg.com) or fax. If you do not have an original terminal (banana plug above the mainframe mul- shipping carton, you may obtain one by calling tipoint connector). -
Page 5: Control Elements
C o n t r o l - E l e m e n t s 16 17 9 10 11 12 14 15 Current in excess of 10 A (max. 20 A) must Control-Elements not be applied for a period exceeding 30 s, otherwise the internal measurement resistor thermal device will blow. - Page 6 C o n t r o l - E l e m e n t s on the display during initial action on the HOLD/ AUTO (pushbutton) OFFSET key . Activate this function by means of Pushbutton for switching the AUTO range selec- a second press on the HOLD/OFFSET key.
- Page 7 It is possible to move from one func- Measurement inputs tion directly to any other function by a successive series of pressings. The HM8012 has four safety terminals with which, Mode selection when using appropriate measurement cables (e.g. HZ15), unintended contacts with the measurand For current and voltage modes, the AC-DC key are nearly impossible.
-
Page 8: Ac Voltage Measurement
The maximum input voltage of HM8012 is 600 V when the COM terminal is The HM8012 should be connected to the circuit to ground potential, i.e. by connecting whose potential with respect to ground is lowest. HM8012 to the object to be measured,... -
Page 9: Resistance Measurements
F u n c t i o n s alternating voltage height with the measuring The HM8012 crest factor ranges from 1 to 7 (for range choice. additional measurement error of <1%) and de- pends on the magnitude of the rms value of the Resistance measurements signal to be measured. -
Page 10: Temperature Measurements
It is possible to measure voltages up to 5 V. The maximum voltage that the equipment will The HM8012 is used for DC or AC voltage supply is 10 V in an open circuit. If the cathode measurements in decibels. The 0 dB reference of the DUT is connected to the ground (COM- is defi... -
Page 11: Function Commands
These correspond to the “RANGE” keys on the front panel. I? <CR> Request for equipment identifi cation which returns: AY<CR> switches to automatic range change HAMEG, HM8012, V1.03<CR> AN<CR> switches to manual range change I.e.: manufacturer, instrument Subject to change without notice... - Page 12 R e m o t e c o n t r o l reference, void and software version (1 - > 0.5 V, 0.5k , 500 μA, T°C, T°F) (Firmware). (2 - > 5 V, 5 k , 5 mA, Diode) (3 - >...
-
Page 13: Function Test
500 mV 250 mV (1) 248.65 - 251.35 This test should help verify, at certain intervals, the functions of HM8012 without any great expen- (2) 247.15 - 252.85 diture in measurement instruments. To achieve 2.5 V (1) 2.4865 - 2.5135 thermal balance, the module and the basic instru- (2) 2,4715 - 2.5285... -
Page 14: Wdm8012 Software
W D M 8 0 1 2 S o f t w a r e WDM8012 SOFTWARE A CD-ROM is provided with the HM8012 multi- meter, including the user manual, the WDM8012 ® software running under Windows , as well as an ®...
Table of Contents
Rename the bookmark
CancelDelete bookmark?
Cancel DeleteDelete from my manuals?
Cancel DeleteLogin
Sign In OR Sign in with Facebook Sign in with Google Don't have an account? Sign up! Restore passwordUpload manual
Upload from disk Upload from URL Thank you for your help!Từ khóa » Hm8012
-
HM8012 Multimeter Module | Overview - Rohde & Schwarz
-
HM8012 HAMEG INSTRUMENTS | LCD 4,75 Digit (50000);
-
R & S – HM8012 Multimeter Module - All Measure Technology
-
R & S - HM8012 Multimeter Module - All Measure Technology
-
Hameg HM8012 4 Digit Programmable Multimeter - Testwall
-
Hameg HM8012 Digit Programmable Multimeter - TEquipment
-
Rohde & Schwarz HM8012 Bench Digital Multimeter | 449-9937
-
Rohde & Schwarz HM8012 Bench Digital Multimeter, With RS ...
-
Rohde & Schwarz HM8012 Bench Digital Multimeter
-
HM8012 | Rohde & Schwarz Digital Multimeter | Distrelec Export Shop
-
HM8012 3593.0768.02 Rohde & Schwarz - All About Circuits
-
Hameg HM8012 Programmable Multimeter - Manualzz
-
[PDF] Hameg HM8012 Multimeter - Service Manual.pdf
-
HM8012 - SM5CBW's Hameg Modules
Multimeter Hameg HM8012 Manual 4 3/4 - digit multimeter (68 pages)
Multimeter Hameg HM8012 Manual 4 3/4-digit multimeter (68 pages)
Multimeter Hameg HM8012 Service Manual 4 3/4 digit multimeter (29 pages)
Multimeter Hameg HMC8012 Programmer's Manual Scpi commands (72 pages)
Multimeter Hameg HM8011-3 Operating Manual Hm8011-3 (33 pages)
Multimeter Hameg HM8011-3 Service Manual (9 pages)
Multimeter Hameg HM8112-3S Manual 6 1/2 digit precision multimeter (56 pages)
Multimeter Hameg HM8010 Manual 4 3/4 - digit multimeter (60 pages)