Hanna Digital Refractometer For Ethylene Glycol Analysis - HI96831
- Home
- Hanna
- Digital Refractometers
- Hanna Digital Refractometer for Ethylene Glycol Analysis - HI96831
$257.00Qty123456789101112131415161718192021222324252627282930 Discontinued
Ask a Question Send This Page to a FriendAsk an Expert
Our tech experts are ready to help!1-866-4 JJSTECH (1-866-455-7832)
Email Us Share this product:Hanna Digital Refractometer for Ethylene Glycol Analysis - HI96831
$257.00Discontinued
- Description
- Specifications
- Datasheets & User Manuals
- Questions
- Reviews
- Description
HI96831 Digital Refractometer for Ethylene Glycol Analysis by Hanna Instruments
The HI 96831 Ethylene Glycol Digital Refractometer is a rugged, portable, water resistant device that utilizes the measurement of refractive index to determine the percent volume and freezing point of ethylene glycol based solutions.
This digital refractometer eliminates the uncertainty associated with mechanical refractometers. HI 96831 samples are measured after a simple user calibration with distilled or deionized water. Within seconds, the refractive index and temperature are measured and converted into one of two measurement units; % volume or freezing point. These meters use internationally recognized references for unit conversion and temperature compensation for glycol solutions (e.g. CRC Handbook of Chemistry and Physics, 87th Edition).
- The dual-level LCD displays measurement and temperature readings simultaneously
- Automatic Temperature Compensation for accurate measurements
- Easy measurement; place a few drops of the sample in the well and press the READ key
- BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.
- IP65 water protection; built to perform under harsh laboratory and field conditions.
- Quick, accurate results, readings are displayed in approximately 1.5 seconds.
- Single point calibration with distilled or deionized water
- Small sample size, can be as small as 2 metric drops.
- Automatic shut-off after three minutes of non-use
- Stainless steel sample well, easy to clean and corrosion resistant
- ABS thermoplastic casing
Order Information:
HI 96831 is supplied with battery and instruction manual.![]()
- Specifications
| % Volume Range | 0 to 100 % |
| Freezing Point Range | 0 to -50 °C (32 to -58 °F) |
| Temperature Range | 0 to 80 °C (32 to 176 °F) |
| % Volume Resolution | 0.1 % |
| Freezing Point Resolution | 0.1 °C (0.1 °F) |
| Temperature Resolution | 0.1 °C (0.1 °F) |
| % Volume Accuracy (@20°C) | ±0.2 % |
| Freezing Point Accuracy (@20°C) | ±0.5 °C (±1.0 °F) |
| Temperature Accuracy (@20°C) | ±0.3 °C (±0.5 °F) |
| Temperature Compensation | automatic between 0 and 40°C (32 to 104°F) |
| Measurement Time | approximately 1.5 seconds |
| Minimum Sample Volume | 100 µL (to cover prism totally) |
| Light Source | yellow LED |
| Sample Cell | stainless steel ring and flint glass prism |
| Auto-off | after three minutes of non-use |
| Enclosure Rating | IP 65 |
| Battery Type / Battery Life | 9V / approximately 5000 readings |
| Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
| Weight | 420 g (14.8 oz.) |
- Datasheets & User Manuals
Datasheets & User Manuals
- Questions & Answers
Questions & Answers
Ask a Question- Reviews
Reviews
Hanna Digital Refractometer for Ethylene Glycol Analysis - HI96831 $257.00 Write a ReviewRelated Items in This Section
- Hanna Digital Refractometer for Sugar Analysis Sucrose - HI96801
- Hanna Digital Refractometer for Sugar Analysis Fructose - HI96802
- Hanna Digital Refractometer for Sugar Analysis Glucose - HI96803
- Hanna Digital Refractometer for Sugar Analysis Invert Sugar - HI96804
- Hanna Digital Refractometer for Measurement of Sugar in Wine % of Brix - HI96811
- Hanna Digital Refractometer for Measurement of Sugar in Wine °Baumé - HI96812
- Hanna Digital Refractometer for Measurement of Sugar in Wine %Brix & %V/V - HI96813
- Hanna Digital Refractometer for Measurement of Sugar in Wine %Brix, °Oechsle & °KMW - HI96814
- Hanna Digital Refractometer for Sodium Chloride Measurement - HI96821
- View More ...
Từ khóa » Hi 96831
-
Hanna Instruments HI 96831 Digital Ethylene Glycol Refractometer
-
[PDF] HI 96831 Ethylene Glycol Refractometer - Wolflabs
-
Digital Refractometer For Ethylene Glycol Analysis - HI96831
-
HI-96831 Digital Refractometer For Ethylene Glycol Analysis
-
Hanna HI96831 Digital Refractometer For Ethylene Glycol Analysis
-
Hanna - Model HI 96831 - Ethylene And Propylene Glycol Analysis
-
HI96831 Digital Refractometer For Ethylene Glycol Analysis Hanna ...
-
Hanna Instruments HI 96831 Instruction Manual - ManualsLib
-
Learn About The Hanna Instruments Ethylene Glycol Refractometer ...
-
HANNA HI-96831 Digital Refractometer / Ethylene Glycol Analysis
-
Hanna Instruments HI 96831 Digital Refractometer For Ethylene Glycol ...
-
Glycol - Hanna Instruments Ltd
-
Hanna Instruments HI 96831 User Manual | Page 6 / 12