HI83300 Portable Multiparameter Photometer And PH Meter

  • Home
  • New Products
  • Parameters
  • Applications
  • News
  • About
  • Contact Us
  • Home
  • Applications
  • Photometer/COD
  • HI83300 Portable Multiparameter Photometer and pH Meter
HI83300 Portable Multiparameter Photometer and pH Meter HI83300 Portable Multiparameter Photometer and pH Meter HI83300 Portable Multiparameter Photometer and pH Meter HI83300 Portable Multiparameter Photometer and pH Meter HI83300 Portable Multiparameter Photometer and pH Meter HI83300 Portable Multiparameter Photometer and pH Meter

Product Code : HI83300

Category : Photometer/COD

Catalog : sorry not ready

Request for Quote ×

Request for Quote

HI83300 Portable Multiparameter Photometer and pH Meter

Name * Email * Subject * Message * Close Send Message
  • Description

Product information "HI83300 Portable Multiparameter Photometer and pH Meter"HI83300 is a compact, multiparameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. To save valuable laboratory benchtop space, the HI83300 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.Advanced optical systemUnparalleled performance from a benchtop photometerDigital pH electrode inputSave valuable bench space with one meter that works both as a photometer and as a laboratory pH meterAbsorbance measuring modeAllows performance verification using CAL Check standardsDetailsFrom aluminum to zinc, the HI83300 benchtop photometer measures 37 different key water quality parameters using 60 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.A digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.The HI83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.High Efficiency LED Light SourceAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.High Quality Narrow Band Interference FiltersThe narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.Reference Detector for a Stable Light SourceA beam splitter is used as part of the internal reference system of the HI83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.Large Cuvette SizeThe sample cell of the HI83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.Focusing Lens for Greater Light YieldAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.pH SpecificationspH Range Photometer: 6.5 to 8.5 pHpH electrode: -2.00 to 16.00 pHpH Resolution Photometer: 0.1 pHpH electrode: 0.1 pHpH Accuracy Photometer: ±0.1 pHpH electrode: ±0.01 pHpH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode usedpH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibrationpH Method Photometer: phenol redpH-mV Range ±1000 mVpH-mV Resolution 0.1 mVpH-mV Accuracy ±0.2 mV Oxygen, Dissolved SpecificationsOxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2)Oxygen, Dissolved Resolution 0.1 mg/LOxygen, Dissolved Accuracy ±0.4 mg/L ±3% of readingOxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method Absorbance SpecificationsAbsorbance Range 0.000 to 4.000 AbsAbsorbance Resolution 0.001 AbsAbsorbance Accuracy +/-0.003Abs @ 1.000 Abs AlkalinityAlkalinity Range Freshwater: 0 to 500 mg/L (as CaCO3)Seawater: 0 to 500 mg/L (as CaCO3)Alkalinity Resolution 1 mg/LAlkalinity Accuracy ±5 mg/L ±5% of readingAlkalinity Method Colorimetric method Aluminum SpecificationsAluminum Range 0.00 to 1.00 mg/L (as Al3+)Aluminum Resolution 0.01 mg/LAluminum Accuracy ±0.04 mg/L ±4% of readingAluminum Method Adaptation of the aluminon method Ammonia SpecificationsAmmonia Range Low Range: 0.00 to 3.00 mg/L (as NH3-N)Medium Range: 0.00 to 10.00 mg/L (as NH3-N)High Range: 0.0 to 100.0 mg/L (as NH3-N)Ammonia Resolution 0.01 mg/L; 0.1 mg/LAmmonia Accuracy Low Range: ±0.04 mg/L ±4% of readingMedium Range: ±0.05 mg/L ±5% of readingHigh range: ±0.5 mg/L ±5% of reading at 25 °CAmmonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method Anionic Surfactants SpecificationsAnionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS)Anionic Surfactants Resolution 0.01 mg/LAnionic Surfactants Accuracy ±0.04 mg/L ±3% of readingAnionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS. Bromine SpecificationsBromine Range 0.00 to 8.00 mg/L (as Br2)Bromine Resolution 0.01 mg/LBromine Accuracy ±0.08 mg/L ±3% of readingBromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. Calcium SpecificationsCalcium Range Freshwater: 0 to 400 mg/L (as Ca2+)Seawater: 200 to 600 mg/L (as Ca2+)Calcium Resolution 1 mg/LCalcium Accuracy Freshwater: ±10 mg/L ±5% of readingSeawater: ±6% of readingCalcium Method Freshwater: Adaptation of the Oxalate methodSeawater: Adaptation of the Zincon method ChlorideChloride Range 0.0 to 20.0 mg/L (as Cl?)Chloride Resolution 0.1 mg/LChloride Accuracy ±0.5 mg/L ±6% of reading at 25 °C Chlorine Dioxide SpecificationsChlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2)Chlorine Dioxide Resolution 0.01 mg/LChlorine Dioxide Accuracy ±0.10 mg/L ±5% of readingChlorine Dioxide Method Adaptation of the Chlorophenol Red method. Chlorine SpecificationsTotal Chlorine Range 0.00 to 5.00 mg/L (as Cl2)Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2)Ultra High Range: 0 to 500 mg/L (as Cl2)Total Chlorine Resolution 0.01 mg/L; 0.001 mg/L; 1 mg/LTotal Chlorine Accuracy ±0.03 mg/L ±3% of readingUltra Low Range: ±0.020 mg/L ±3% of readingUltra High Range: ±3 mg/L ±3% of readingChlorine Method Adaptation of the EPA 330.5 DPD methodFree Chlorine (ULR) & Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl Chromium, hexavalent SpecificationsChromium, hexavalent Range Low Range: 0 to 300 ?g/L (as Cr6+)High Range: 0 to 1000 ?g/L (as Cr6+)Chromium, hexavalent Resolution 1 ?g/LChromium, hexavalent Accuracy Low Range: ±1 ?g/L ±4% of readingHigh Range: ±5 ?g/L ±4% of readingChromium, hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method. Color, Water SpecificationsColor, Water Range 0 to 500 PCU (Platinum Cobalt Units)Color, Water Resolution 1 PCUColor, Water Accuracy ±10 PCU ±5% of readingColor, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method. Copper SpecificationsCopper Range Low Range: 0.000 to 1.500 mg/L (as Cu2+)High range: 0.00 to 5.00 mg/L (as Cu2+)Copper Resolution 0.001 mg/L; 0.01 mg/LCopper Accuracy Low Range: ±0.01 mg/L ±5% of readingHigh Range ±0.02 mg/L ±4% of readingCopper Method Adaptation of the EPA bicinchoninate method Cyanuric Acid SpecificationsCyanuric Acid Range 0 to 80 mg/L (as CYA)Cyanuric Acid Resolution 1 mg/LCyanuric Acid Accuracy ±1 mg/L ±15% of readingCyanuric Acid Method Adaptation of the turbidimetric method Fluoride SpecificationsFluoride Range Low Range: 0.00 to 2.00 mg/L (as F-)High range: 0.0 to 20.0 mg/L (as F-)Fluoride Resolution 0.01 mg/L; 0.1 mg/LFluoride Accuracy Low Range: ±0.03 mg/L ±3% of readingHigh Range: ±0.5 mg/L ±3% of readingFluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method Hardness, Total SpecificationsHardness, Total Range Low Range: 0 to 250 mg/L (as CaCO3)Medium Range: 200 to 500 mg/L (as CaCO3)High Range: 400 to 750 mg/L (as CaCO3)Hardness, Total Resolution 1 mg/LHardness, Total Accuracy Low Range: ±5 mg/L ±4% of readingMedium Range: ±7 mg/L ±3% of readingHigh Range: ±10 mg/L ±2% of readingHardness, Total Method Adaptation of the EPA recommended method 130.1 Hardness, Calcium SpecificationsHardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)Hardness, Calcium Resolution 0.01 mg/LHardness, Calcium Accuracy ±0.11 mg/L ±5% of readingHardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method Hardness, Magnesium SpecificationsHardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3)Hardness, Magnesium Resolution 0.01 mg/LHardness, Magnesium Accuracy ±0.11 mg/L ±5% of readingHardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method Hydrazine SpecificationsHydrazine Range 0 to 400 ?g/L (as N2H4)Hydrazine Resolution 1 ?g/LHydrazine Accuracy ±4% of full scale readingHydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method Iodine SpecificationsIodine Range 0.0 to 12.5 mg/L (as I2)Iodine Resolution 0.1 mg/LIodine Accuracy ±0.1 mg/L ±5% of readingIodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method Iron SpecificationsIron Range Low Range: 0.000 to 1.600 mg/L (as Fe)High Range: 0.00 to 5.00 mg/L (as Fe)Iron Resolution 0.001 mg/L; 0.01 mg/LIron Accuracy Low Range: ±0.01 mg/L ±8% of readingHigh Range: ±0.04 mg/L ±2% of readingIron Method Low Range: Adaptation of the TPTZ MethodHigh Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters Magnesium SpecificationsMagnesium Range 0 to 150 mg/L (as Mg2+)Magnesium Resolution 1 mg/LMagnesium Accuracy ±5 mg/L ±3% of readingMagnesium Method Adaptation of the Calmagite method Manganese SpecificationsManganese Range Low Range: 0 to 300 ?g/L (as Mn)High Range: 0.0 to 20.0 (as Mn)Manganese Resolution 1 ?g/L; 0.1 mg/LManganese Accuracy Low Range: ±10 ?g/L ±3% of readingHigh Range: ±0.2 mg/L ±3% of readingManganese Method Low Range: Adaptation of the PAN MethodHigh Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method Molybdenum SpecificationsMolybdenum Range 0.0 to 40.0 mg/L (as Mo6+)Molybdenum Resolution 0.1 mg/LMolybdenum Accuracy ±0.3 mg/L ±5% of readingMolybdenum Method Adaptation of the mercaptoacetic acid method Nickel SpecificationsNickel Range Low Range: 0.000 to 1.000 mg/L (as Ni)High Range: 0.00 to 7.00 g/L (as Ni)Nickel Resolution 0.001 mg/L; 0.01 g/LNickel Accuracy Low range: ±0.010 mg/L ±7% of readingHigh Range: ±0.07 g/L ±4% of readingNickel Method Low Range: Adaptation of the PAN methodHigh Range: Adaptation of the photometric method Nitrate SpecificationsNitrate Range 0.0 to 30.0 mg/L (as NO3-- N)Nitrate Resolution 0.1 mg/LNitrate Accuracy ±0.5 mg/L ±10% of readingNitrate Method Adaptation of the cadmium reduction method Nitrite SpecificationsNitrite Range FreshwaterLow Range: 0 to 600 ?g/L (as NO2--N)High Range: 0 to 150 mg/L (as NO2-)Seawater Ultra Low Range: 0 to 200 ?g/L (as NO2--N)Nitrite Resolution Freshwater: 1 ?g/L; 1 mg/LSeawater: 1 ?g/LNitrite Accuracy FreshwaterLow Range: ±20 ?g/L ±4% of readingHigh Range: ±4 mg/L ±4% of readingSeawater±10 ?g/L ±4% of readingNitrite Method Adaptation of the EPA Diazotization method 354.1 Oxygen, Scavenger SpecificationsOxygen, Scavenger Range 0 to 1000 ?g/L (as DEHA)0.00 to 1.50 mg/L (as Carbohydrazide)0.00 to 2.50 mg/L (as Hydroquinone)0.00 to 4.50 mg/L (as ISO-ascorbic acid)Oxygen, Scavenger Resolution 1 ?g/L (DEHA); 0.01 mg/LOxygen, Scavenger Accuracy ±5 ?g/L ±5% of reading (DEHA)Oxygen, Scavenger Method Adaptation of the iron reduction method Ozone SpecificationsOzone Range 0.00 to 2.00 mg/L (as O3)Ozone Resolution 0.01 mg/LOzone Accuracy ±0.02 mg/L ±3% of readingOzone Method Colorimetric DPD Method Phosphate SpecificationsPhosphate Range FreshwaterLow Range: 0.00 to 2.50 mg/L (as PO43-)High range: 0.0 to 30.0 mg/L (as PO43-)Seawater Ultra Low Range: 0 to 200 ?g/L (as P)Phosphate Resolution Freshwater: 0.01 mg/L; 0.1 mg/LSeawater: 1 ?g/LPhosphate Accuracy FreshwaterLow Range: ±0.04 mg/L ±4% of readingHigh Range: ±1 mg/L ±4% of readingSeawater Ultra Low Range: ±5 ?g/L ±5% of readingPhosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid methodFreshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method Potassium SpecificationsPotassium Range 0.0 to 20.0 mg/L (as K)Potassium Resolution 0.1 mg/LPotassium Accuracy ±3.0 mg/L ±7% of readingPotassium Method Adaptation of the Turbidimetric Tetraphenylborate method Silica SpecificationsSilica Range Low Range: 0.00 to 2.00 mg/L (as SiO2)High Range: 0 to 200 mg/L (as SiO2)Silica Resolution 0.01 mg/L; 1 mg/LSilica Accuracy Low Range: ±0.03 mg/L ±3% of readingHigh Range: ±1 mg/L ±5% of readingSilica Method Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue methodHigh Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO2 Silver SpecificationsSilver Range 0.000 to 1.000 mg/L (as Ag)Silver Resolution 0.001 mg/LSilver Accuracy ±0.020 mg/L ±5% of readingSilver Method Adaptation of the PAN method Sulfate SpecificationsSulfate Range 0 to 150 mg/L (as SO42-)Sulfate Resolution 1 mg/LSulfate Accuracy ±5 mg/L ±3% of readingSulfate Method Turbidimetric - Sulfate is precipitated with barium chloride crystals Zinc SpecificationsZinc Range 0.00 to 3.00 mg/L (as Zn)Zinc Resolution 0.01 mg/LZinc Accuracy ±0.03 mg/L ±3% of readingZinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method General Meter SpecificationsInput Channels 1 pH electrode input and 5 photometer wavelengthspH Electrode digital pH electrode (not included)Logging Type log on demand with user name and sample ID optional inputLogging Memory 1000 readingsConnectivity USB-A host for flash drive; micro-USB-B for power and computer connectivityGLP calibration data for connected pH electrodeDisplay 128 x 64 pixel LCD with backlightBattery Type / Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurementPower Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)Environment 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensingDimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8")Weight 1.0 kg (2.2 lbs.)Photometer/Colorimeter Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filtersPhotometer/Colorimeter Light Detector silicon photodetectorBandpass Filter Bandwidth 8 nmBandpass Filter Wavelength Accuracy ±1 nmCuvette Type round, 24.6 mmNumber of Methods 128 max.Ordering Information HI83300 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

Từ khóa » Hi83300