HM-100 - HIOS

HM-100
  • HM Series
Distributor Document Request

Feature

Use for torque control of screwdrivers for automatic assembly machines

● Measured data can be imported to a computer. ● Up to 100 data items can be stored in the memory and controlled (applicable to HP and HDP only). ● With one unit of Torque Meter, max, min and ave torque values can be measured (applicable to HP and HDP only). ● New product, HP-1 is ideal for measuring 10N・cm or smaller torque. ● Torque for both clockwise or counterclockwise can be measured. ● As a standard specificataon, data output and analogue output are available. ● We offer calibration and maintenance services. ● “Inspection Report” is attached to all the Torque Meters.

HM-100

Specification

Download

  • User's Manual (pdf)
  • DXF(Panel)
  • DXF(Detector+Fidaptor)

Peak mesuring range

  • N・m

  • lbf・in

Accuracy

Measuring models

External Dimensions(mm)

  • Display unit

  • Detector

Weight(g)

  • Torque display

  • Detector

Detectorcord

Charging time

Continuous operating time ona full charge

Battery life

Exclusive battery charger

  • 0.15-10
  • 15-1000
  • Within ±0.5% (F.S.)
  • TRACK and PEAK
  • 165 ×95 ×55 (H)
  • 119×45×33(H)
  • 1kg
  • 0.35kg
  • 1.7m (P/N: DPC-0506)
  • 6V NiMH (within 8 hours)
  • 8 hours
  • About 300 charges
  • Input:AC100V,120V,220-240V Output:DC 7.2V 120mA

HM-100Standard Accessories

Fidaptor with screw(1pc ) P/N:TFM40-Z (Black)
Buffer spring Measuring range:0.15-0.6 N • m P/N:CL65-0040
Screw Replacement screws on the top of fidaptor 5pcs HEX socket set screws for fixing: 2 pcs
L- wrench 1.5mm 1pc、2mm 1pc
Others Exclusive battery charger 1pcP/N:TCH-100N ※Overseas charger plug is different in kind depeding on country.
Detector cord: 1.7m 1pc P/N:DPC-0506
Inspection report 1 copy

HM-100Fidaptor List

Classification Standard accessories
P/N TFM40-Z
Measuring range(N・m) 0.5-3
  (Black)
Applicable tip No. +#2
crew head diameter M4.0

HM Battery Charger

国別 Voltage The battery charger Order Code
Japan AC100V A Plug TCH-100N
Canada, Taiwan, US, Korea AC100-120V A Plug TCH-120N
China, HK AC220-240V C Plug TCH-230G
Australia, UK, Singapore AC220-240V BF Plug TCH-230B

Series Comparison

Model

Peak mesuring range

  • N・m

  • kgf・cm

  • lbf・in

Accuracy

Measuring models

External Dimensions(mm)

    • External Dimensions(mm)
  • Display unit

  • Detector

Weight(g)

    • Weight(g)
  • Torque display

  • Detector

Detector

  • Bit socket

Detectorcord

Charging time

Continuous operating time ona full charge

Battery life

Exclusive battery charger

HM-10

  • 0.015-1
  • -
  • 1.5-100
  • Within ±0.5% (F.S.)
  • TRACK and PEAK
  • 165 ×95 ×55 (H)
  • 119×45×33(H)
  • 1kg
  • 0.35kg
  • 1.7m (P/N: DPC-0506)
  • 6V NiMH (within 8 hours)
  • 8 hours
  • About 300 charges
  • Input:AC100V,120V,220-240V Output:DC 7.2V 120mA

HM-100

  • 0.15-10
  • -
  • 15-1000
  • Within ±0.5% (F.S.)
  • TRACK and PEAK
  • 165 ×95 ×55 (H)
  • 119×45×33(H)
  • 1kg
  • 0.35kg
  • 1.7m (P/N: DPC-0506)
  • 6V NiMH (within 8 hours)
  • 8 hours
  • About 300 charges
  • Input:AC100V,120V,220-240V Output:DC 7.2V 120mA

Từ khóa » H&m 100