Ligamentous Laxity Across C0-C1-C2 Complex. Axial Torque-rotation ...
The .gov means it’s official. Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.
The site is secure. The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation Search: Search Advanced Clipboard Save Email Send to- Clipboard
- My Bibliography
- Collections
- Citation manager
Save citation to file
Format: Summary (text) PubMed PMID Abstract (text) CSV Create file CancelEmail citation
Subject: 1 selected item: 2263977 - PubMed To: From: Format: Summary Summary (text) Abstract Abstract (text) MeSH and other data Send email CancelAdd to Collections
- Create a new collection
- Add to an existing collection
Add to My Bibliography
- My Bibliography
Your saved search
Name of saved search: Search terms: Test search terms Would you like email updates of new search results? Saved Search Alert Radio Buttons- Yes
- No
Create a file for external citation management software
Create file CancelYour RSS Feed
Name of RSS Feed: Number of items displayed: 5 10 15 20 50 100 Create RSS Cancel RSS Link CopyActions
CiteCollectionsAdd to Collections- Create a new collection
- Add to an existing collection
Share
- Permalink Copy
Page navigation
- Title & authors
- Abstract
- Similar articles
- Cited by
- Publication types
- MeSH terms
- Related information
- Grants and funding
- LinkOut - more resources
Abstract
The axial torque until failure of the ligamentous occipito-atlanto-axial complex (C0-C1-C2) subjected to axial angular rotation (theta) was characterized using a biaxial MTS system. A special fixture and gearbox that permitted right axial rotation of the specimen until failure without imposing any additional constraints were designed to obtain the data. The average values for the axial rotation and torque at the point of maximum resistance were, respectively, 68.1 degrees and 13.6 N-m. The specimens offered minimal resistance (approximately 0.5 N-m), up to an average axial rotation of 21 degrees across the complex. The torque-angular rotation (T-theta) curve can be divided into four regions: regions of least and steadily increasing resistances, a transition zone that connects these two regions, and the increasing resistance region to the point of maximum resistance. The regions of least and steadily increasing resistances may be represented by two straight lines with average slopes of 0.028 and 0.383 N-m/degree, respectively. Post-test dissection of the specimens disclosed the following. The point of maximum resistance corresponded roughly to the value of axial rotation at which complete bilateral rotary dislocation of the C1-C2 facets occurred. The types of injuries observed were related to the magnitude of axial rotation imposed on a specimen during testing. Soft-tissue injuries alone (like stretch/rupture of the capsular ligaments, subluxation of the C1-C2 facets, etc.) were confined to specimens rotated up to or close to the point of maximum resistance. The specimens that were subjected to rotations up to the point of maximum resistance of the curve spontaneously reduced completely on removal from the testing apparatus. Spontaneous reduction was not possible for specimens tested slightly beyond their points of maximum resistance.(ABSTRACT TRUNCATED AT 250 WORDS)
PubMed Disclaimer
Similar articles
- Dynamic response of the occipito-atlanto-axial (C0-C1-C2) complex in right axial rotation. Chang H, Gilbertson LG, Goel VK, Winterbottom JM, Clark CR, Patwardhan A. Chang H, et al. J Orthop Res. 1992 May;10(3):446-53. doi: 10.1002/jor.1100100318. J Orthop Res. 1992. PMID: 1569507
- Effects of alar ligament transection on upper cervical spine rotation. Panjabi M, Dvorak J, Crisco JJ 3rd, Oda T, Wang P, Grob D. Panjabi M, et al. J Orthop Res. 1991 Jul;9(4):584-93. doi: 10.1002/jor.1100090415. J Orthop Res. 1991. PMID: 2045985
- Development of a computer model to predict strains in the individual fibers of a ligament across the ligamentous occipito-atlanto-axial (C0-C1-C2) complex. Goel VK, Yamanishi TM, Chang H. Goel VK, et al. Ann Biomed Eng. 1992;20(6):667-86. doi: 10.1007/BF02368612. Ann Biomed Eng. 1992. PMID: 1449233
- Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis. Du JY, Aichmair A, Kueper J, Wright T, Lebl DR. Du JY, et al. J Neurosurg Spine. 2015 Feb;22(2):151-61. doi: 10.3171/2014.10.SPINE13805. Epub 2014 Dec 5. J Neurosurg Spine. 2015. PMID: 25478824 Review.
- What is new in mechanical properties of tissue-engineered organs. Auger FA, Berthod F, Goulet F, Germain L. Auger FA, et al. Curr Top Pathol. 1999;93:87-93. doi: 10.1007/978-3-642-58456-5_9. Curr Top Pathol. 1999. PMID: 10339901 Review. No abstract available.
Cited by
- Distinguishing Different Emotions Evoked by Music via Electroencephalographic Signals. Hou Y, Chen S. Hou Y, et al. Comput Intell Neurosci. 2019 Mar 6;2019:3191903. doi: 10.1155/2019/3191903. eCollection 2019. Comput Intell Neurosci. 2019. PMID: 30956655 Free PMC article.
- Chronic neck pain: making the connection between capsular ligament laxity and cervical instability. Steilen D, Hauser R, Woldin B, Sawyer S. Steilen D, et al. Open Orthop J. 2014 Oct 1;8:326-45. doi: 10.2174/1874325001408010326. eCollection 2014. Open Orthop J. 2014. PMID: 25328557 Free PMC article.
- A geometrical model of vertical translation and alar ligament tension in atlanto-axial rotation. Boszczyk BM, Littlewood AP, Putz R. Boszczyk BM, et al. Eur Spine J. 2012 Aug;21(8):1575-9. doi: 10.1007/s00586-012-2209-z. Epub 2012 Mar 2. Eur Spine J. 2012. PMID: 22382726 Free PMC article.
- Artificial atlanto-odontoid joint replacement through a transoral approach. Lu B, He XJ, Zhao CG, Li HP, Wang D. Lu B, et al. Eur Spine J. 2009 Jan;18(1):109-17. doi: 10.1007/s00586-008-0835-2. Epub 2008 Nov 29. Eur Spine J. 2009. PMID: 19043745 Free PMC article.
- Plate and screw fixation for atlanto-axial subluxation. Goel A, Laheri V. Goel A, et al. Acta Neurochir (Wien). 1994;129(1-2):47-53. doi: 10.1007/BF01400872. Acta Neurochir (Wien). 1994. PMID: 7998495
Publication types
- Research Support, U.S. Gov't, P.H.S. Actions
- Search in PubMed
- Search in MeSH
- Add to Search
MeSH terms
- Biomechanical Phenomena Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Biomedical Engineering / instrumentation Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Cadaver Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Cervical Vertebrae / pathology Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Cervical Vertebrae / physiology* Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Humans Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Ligaments / pathology Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Ligaments / physiology* Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Rotation Actions
- Search in PubMed
- Search in MeSH
- Add to Search
- Stress, Mechanical Actions
- Search in PubMed
- Search in MeSH
- Add to Search
Related information
- MedGen
Grants and funding
- AR 32954/AR/NIAMS NIH HHS/United States
LinkOut - more resources
Full Text Sources
- Ovid Technologies, Inc.
Medical
- MedlinePlus Health Information
Miscellaneous
- NCI CPTAC Assay Portal
- Clipboard
- Save
- My Bibliography
- Collections
- Citation Manager
NCBI Literature Resources
MeSH PMC Bookshelf Disclaimer
The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.
Từ khóa » C2 C1 C0
-
The Orientation Of C0, C1, And C2 In Neutral Position. A. C0: The Line...
-
Prove That (1 + C1/C0)(1 + C2/C1)(1 + C3/C2).....(1 + Cn/(Cn
-
The C1-C2 Vertebrae And Spinal Segment - Spine-health
-
Validation Of The Neutral Zone Of A C0–C1–C2 FE Complex
-
What Do The C0, C1, Etc. Mean? | Fandom - Genshin Impact Wiki
-
Prove That C0 - - +C1 - - +C2 - - +.....Cn - Toppr
-
Are The Binomial Coefficients In The Expansion Of (1+x)n. N ... - Toppr
-
( 1+(C1/C0) )( 1+(C2/C1) )( 1+(C3/C2) ).....( 1+(Cn/Cn-1) ) Is Equal To:
-
Mathsmerizing - YouTube
-
Solved A Four-bit Control Code (C0, C1, C2, C3) Is Used In A - Chegg
-
[2107.03604] Measurement Of $e^+e^-\toγχ_{c0,c1,c2}$ Cross ...
-
Giới Thiệu Khái Niệm Test Coverage (C0/C1/C2) - Viblo