96M13087 Multi Camera High Performance Machine Vision System XG-8000 Series Controller Instruction Manual Read this manual thoroughly before using the XG-8000 Series. Always keep this manual in a safe place for future reference. Introduction This manual describes the hardware information. Read this manual thoroughly to understand the performance and functions of the “Multi Camera High Performance Machine Vision System XG-8000 Series” in order to maximize the performance of the system.
PAGE 2
Safety Precautions Symbols The following warning symbols are used to ensure safety and to prevent human injury and/or damage to property when using the system. Measures to be taken when an abnormality occurs In the following cases, turn the power OFF immediately. Using the unit in an abnormal condition may cause fire, electric shock, or product malfunction. Contact your local KEYENCE office for repair.
PAGE 3
Identifying Controls and Connectors Note • Camera input unit CA-EC80HX cannot be used with the XG-8800L(P). Camera input unit CA-EC80HX/CA-EC80L/XG-EC80L cannot be used with the XG-8800(P). • If the firmware of the camera input unit is old, an error message will be displayed at the startup of the device (Ver.5.0.0020 or later). In this case, execute an update with the latest firmware with the camera input unit attached.
PAGE 4
Installing the Controller Unit Installing the Expansion Unit Install the controller unit to DIN rail, or use the holes on the bottom of the controller to secure it with screws. Note • Do not install the XG in a location with lots of dust or water vapor. The XG does not have a mechanism to protect the XG from dust or water. Dust or water entering the controller can cause damage to the XG. • Turn off the power to the controller when connecting or removing an expansion unit, a cable, or a terminal block.
PAGE 5
Installing the CV Connecting the Camera Cables Installing the Controller on a DIN Rail Connect the camera to the camera connector of the controller unit using one of the optional camera cables. If connecting only a single camera, attach it to the camera 1 connector. The controller unit and the expansion unit are designed to be mounted on a DIN rail. Pull out the tab on the bottom in the direction of the arrow to mount or dismount the controller.
PAGE 6
Connecting the 24 VDC Power Source Parallel I/O Assignment: When Using Cable OP-51657 (Sold Separately) Connect a 24 VDC power source to the power source/earth terminal. No. Note • Use an AWG14-AWG22 Power cable. • Always connect the Frame Ground Terminal of the 24 VDC power source to a D type ground. • Use a Crimping Terminal the size shown below that matches an M3 screw. • Securely tighten with a screw tightening torque of 0.5-0.75 [N·m] Ring Terminal Y Terminal 5.8 mm or less 1 2 5.
PAGE 7
Terminal Block 1 Terminal Block 2 (XG-8500L(P)/8502L(P)/ 8700L(P)/8702L(P)/8800(P)/8802(P)/ 8800L(P)/8802L(P) only) Standard Specifications The following values show the terminal block 1 specifications for the system. Standard Specifications Note Tightening with a force above the standard torque may cause damage to the terminal block. OUT1 connector The following values show the terminal block 2 specifications for the system.
PAGE 8
Input/Output Circuit Note • Use a shield cable that supports an RS-422 signal for the connection to the IN2 Connector for encoder input, and always connect the Cable shield to the FG. • Power source 0 V and COMIN1, COMIN2 (Connector), COMIN2 (Terminal block), COMOUT1, COMOUT2, COMOUT_F+, COMOUT_F-, COMOUT2_F+, COMOUT2_F-, and 0VOUT are all isolated. • COMOUT2_F+ and COMOUT2_F- are the common terminal for dedicated output for OUT2 Connector 1 through to 4.
PAGE 9
Main Specifications XG-8000(P)/8002(P)/8500(P)/8502(P)/8700(P)/8702(P) Model type XG-8700/8702 XG-8500/8502 XG-8000/8002 • With CA-HX200C/HX200M connected 2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels • With CA-HX048C/HX048M connected 470 k pixel mode: 784(H) x 596(V), approx. 470,000 pixels 310 k pixel mode: 640(H) x 480(V), approx. 310,000 pixels 240 k pixel mode: 512(H) x 480(V), approx.
PAGE 10
XG-8500L(P)/8502L(P)/8700L(P)/8702L(P) Model type XG-8700L/8702L • With CA-H2100C/H2100M, XG-H2100C/H2100M connected 21 mega-pixel mode: 5104(H)x4092(V), approx. 20.89 mega-pixels 5 mega-pixel mode: 2432(H)x2050(V), approx. 4.99 mega-pixel • With XG-HL08M is connected: 8192(H) x 8192(L), approx. 67.11 mega-pixels • With XG-HL04M is connected: 4096(H) x 16384(L), approx. 67.11 mega-pixels • With XG-HL02M is connected: 2048(H) x 16384)L), approx. 33.
PAGE 11
XG-8800(P)/8802(P)/8800L(P)/8802L(P) Model type Pixels Camera input Trigger input XG-8800/8802 XG-8800L/8802L • With XG-H500C/H500M connected 5 mega-pixel mode: 2432(H) x 2050(V), approx. 4.99 mega-pixels • With XG-200C/S200C/H200C/200M/S200M/H200M connected 2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels 1 mega-pixel mode: 1024(H) x 960(V), approx.
PAGE 12
Dimensions Warranties and Disclaimers Controller Unit XG-8000(P)/8002(P)/8500(P)/8502(P)/8700(P)/8702(P)/8500L(P)/ 8502L(P)/8700L(P)/8702L(P) 23.5 134.6 132.0 DIN rail installation part 153.0 35.9 83.3 65.3 6.0 (92.0) 116.7 M4 depth: 11.0 M4 depth: 11.0 112.0 M4 depth: 6.0 80.0 M4 16.5 depth: 6.0 XG-8800(P)/8802(P)/8800L(P)/8802L(P) 23.5 206.5 132.0 DIN rail installation part 153.0 35.9 83.3 65.3 6.0 (92.0) M4 depth: 6.0 M4 depth: 11.0 M4 depth: 11.0 70.0 M4 depth: 11.0 M4 depth: 11.
Từ khóa » Xg-8500l
-
XG-8500L - Line Scan Camera - Keyence Singapore
-
Multi-camera Imaging System/Controller - XG-8500
-
XG-8500L - Multi-camera Imaging System/Line Scan ... - Keyence
-
100% NEW KEYENCE XG-8500L In Box XG8500L (DHL) | EBay
-
NEW XG-8500L XG8500L By DHL Or EMS - EBay
-
XG-8500L XG8500L New In Box - AliExpress Home Improvement
-
KEYENCE XG-8000 Series User Manual | 12 Pages
-
Bộ điều Khiển Camera Công Nghiệp Keyence XG-8500
-
多用摄像机图像系统/行扫描摄像机对应控制器- XG-8500L
-
XG-8500L XG-8500全新原装正品KEYENCE基恩士线型扫描相机控制器
-
XG-8500L参数对比 - 中国工控网
-
キーエンス Xg 8500(電材、配電用品)の中古品・新品・未使用品一覧
-
As 103487 XG-8000 Im 96M13087 GB WW 1039-3 PDF - Scribd