PH36904: INZI800E ACTION: GET RC: 0X8 REASON: 0X78 AND SUBSEQUENT HANGINGSITUATION OR ABENDS47B OR INZU362E WITH RC 0XBA004 OR ABENDU1205A fix is available
Obtain the fix for this APAR.
Subscribe
You can track all active APARs for this component.
Notify me when an APAR for this component changes.
APAR status
Closed as program error.
Error description
- (HPU 5.1 only) An unload run in native mode and exploiting ZIIP processors issues the following message : INZI800E ERROR ACCESSING TO A DATASET. ACTION : GET RC: 0x8 REASON: 0x78 and subsequently either : - hangs - or terminates with ABENDS47B - or terminates with completion code of 8 after having issued the following messages INZU362E UNLOAD 00001 FROM TABLESPACE dbname.tsname FAILED POS(1, 3). RC = 0xba004 INZU447E AN ERROR OCCURRED DURING UNLOAD PROCESSING - REFER TO PREVIOUS EXPLANATION MESSAGES. INZU366I UTILITY RETURN CODE 8 (REASON CODE 0xba004) This occurs only when Db2 HPU retrieves the data from an online tablespace or from a Flash Image Copy dataset. It more likely occurs if the value of VUM023/VSBUFND is set to a value lower than the default and recommended value, i.e; 360. The following subparameter VUU030/ULOPTNS will allow the customer to enable/test the fix. ------ FIX(APAR_PH36904[,VERBOSE]) APAR_PH36904 : Enables the fix of APAR PH36904. VERBOSE : specify the additional VERBOSE option to request the WTO INZX001 message be issued whenever the fix for PH36904 is used. As this issue cannot be recreated at will, this feature helps validating the fix once in place. To do so, enable the verbose mode of the fix by specifying FIX(APAR_PH36904,VERBOSE) and by controlling the output of any unload that has issued the INZX001 message. Once the fix has been validated, just ignore the INZX001 message or remove the VERBOSE option to prevent INZX001 to be issued. The fix is disabled by default. ----- As this will be an official fix, its reliability will allow the customer to install it in production and to check its impact.
Local fix
- if applicable, consider increasing the value of VUM023/VSBUFND to a value closer to 360 and, if the issue still occurs, disable the use of zIIP processors with ZIIP OFF or run the unload in SQL mode by specifying the DB2 FORCE option,
Problem summary
- **************************************************************** * USERS AFFECTED: Users of Db2 High Performance Unload * * for z/OS * **************************************************************** * PROBLEM DESCRIPTION: An unload run in native mode issues and * * exploiting zIIP processors the * * following message: * * INZI800E ERROR ACCESSING TO A DATASET. * * ACTION: GET RC: 0x8 REASON: 0x78 * * and subsequently either : * * - hangs * * - or terminates with ABENDS47B * * - or terminates with completion code of * * 8 after having issued the following * * messages * * INZU362E UNLOAD 00001 FROM * * TABLESPACE dbname.tsname FAILED * * POS(1, 3). RC = 0xba004 * * INZU447E AN ERROR OCCURRED DURING * * UNLOAD PROCESSING - REFER TO * * PREVIOUS EXPLANATION MESSAGES. * * INZU366I UTILITY RETURN CODE 8 * * (REASON CODE 0xba004) * * * * This occurs only when Db2 HPU retrieves the data from an * * online tablespace or from a Flash Image Copy dataset. * * * * It more likely occurs if the value of VUM023/VSBUFND is * * set to a value lower than the default and recommended * * value i.e; 360. * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** Message INZI800E ACTION: GET RC: 0x8 REASON: 0x78 and subsequent hanging situation or ABENDS47B or INZU362E with reason code 0xba004.
Problem conclusion
- Code has been changed to fix this problem
Temporary fix
Comments
APAR Information
APAR number
PH36904
Reported component name
DB2 HI PERF UNL
Reported component ID
5697F4400
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-05-04
Closed date
2021-07-08
Last modified date
2024-06-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
- INZUTILK
Fix information
Fixed component name
DB2 HI PERF UNL
Fixed component ID
5697F4400
Applicable component levels
R510 PSY UI76253
UP21/07/14 P F107
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Document Information
Modified date: 12 June 2024
Page Feedback
Share your feedback
Need support?
- Submit feedback to IBM Support
1-800-IBM-7378 (USA)
- Directory of worldwide contacts
Từ khóa » C 0x8
-
0X8 To Decimal
-
What Does "(int) Value & 0x1, (int) Value & 0x2, (int) Value & 0x4, (int ...
-
What Is The Reason For Underscore In C Variable Name Definition?
-
Time Synchronization May Not Succeed - Windows Server
-
Windows Time Service Won't Synchronize - Microsoft Q&A
-
[Solved] 0X7 0X8 $2,120,000 $3,000 ($25,000) Sales ... - Cliffs Notes
-
0X8 Ligand Summary Page - RCSB PDB
-
DIN 7337A Al/St 4,0x8 Blind Rivet - Etra
-
Pfister SecurePfit 3-1/4 In. Extension Kit For 0X8-340A P9700830
-
Dokaply MDO W Backer 18mm 4'-0x8'-0 TKC - Doka Online Shop
-
0x8 To Decimal - Silicon Valley Gazette
-
DIN 7337A St/St 4,0x8 Blind Rivet - Etra
-
STARCO Flex Pro Spare Wheel 4,0x8 Wheel For Wheelbarrow ...