RKI Instruments GH-6001 Combustible Gas Monitor, 0-500 Ppm ...

  1. Home
  2. RKI Instruments
  3. RM-6000
  4. RM-6000 Single-Channel Gas Monitors
  5. RKI Instruments GH-6001 Combustible Gas Monitor, 0-500 ppm DCM (dicloromethane),100-240 VAC input, 60Hz - GH-6001A-02
RKI Instruments GH-6001 Combustible Gas Monitor, 0-500 ppm DCM (dicloromethane),100-240 VAC input, 60Hz - GH-6001A-02 Item #: GH-6001A-02Brand: RKI InstrumentsRKI Instruments GH-6001 Combustible Gas Monitor, 0-500 ppm DCM (dicloromethane),100-240 VAC input, 60Hz - GH-6001A-02$766.50Qty123456789101112131415161718192021222324252627282930 Ask a Question Send This Page to a Friend
  • JJS Technical Services
  • JJS Technical Services
  • JJS Technical Services
  • JJS Technical Services
  • JJS Technical Services
  • JJS Technical Services
  • JJS Technical Services

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us Share this product: RKI Instruments GH-6001 Combustible Gas Monitor, 0-500 ppm DCM (dicloromethane),100-240 VAC input, 60Hz - GH-6001A-02

RKI Instruments GH-6001 Combustible Gas Monitor, 0-500 ppm DCM (dicloromethane),100-240 VAC input, 60Hz - GH-6001A-02

$766.50
  • Description
  • Specifications
  • Datasheets & User Manuals
  • Questions
  • Reviews
  • Description

GH-6001A-02 GH-6001 Combustible Gas Monitor, 0-500 ppm DCM (dicloromethane),100-240 VAC input, 60Hz by RKI Instruments

Features

  • Compact and light weight
  • Bar meter and digital multi-indication
  • Simply fixturable
  • Two alarm levels, trouble alarm
  • Maintenance mode function
  • RoHS Compliant
  • Global standard

Applications

  • LPG, LNG utilities
  • Refineries
  • Petro-refinery, Petrochemical plants
  • Chemical plants
  • Semi-conductor manufacturing plants
  • Engineering, public works
  • Power station
  • Iron and steel works

*Please note we can only ship RKI products to customers within the United States

  • Specifications
RM-6000 series GP-6001 NC-6001(W) SP-6001 GH-6001 EC-6002 OX-6001 OX-6002 RM-6002 RM-6003
Detection gas Combustible Combustible / Toxic Toxic Oxygen Combustible / Toxic / Oxygen
Indication 3-color LCD bar meter (52 dots)
Type of acceptable detector head Catalytic combustion New ceramic Special catalytic / semiconductor combination sensor Semiconductor Electrochemical cell Galvanic cell 4-20mA outputs
2-wire type 3-wire type
Acceptable input signal Direct sensor signal 4-20mA output Direct sensor signal 4-20mA output
Applicable cable CVV-4C CVVS-3C CVVS-2C CVVS-3C
Max distance Max 1.0km Max 1.0km Max 2.0km Max 600m Max 2.0km
Output signal Output of electric power transmission (non-isolated) 4-20mADC, max loop load 300 ohm
Alarm indication Flashing or lighting lamp: Red(AL1), Red (AL2), Latching or non-latching, Locking mode
Trouble alarm Orange lamp flashing (FAULT), Non-latching
Alarm relays Normally energized or de-energized, Normally-open or closed contact Rated 1A at 125VAC, 1A at 30VDC (resistive)
Operation condition -10 -50°C, below 95%RH (non-condensing)
Power requirement Ac type: 100 -240 VAC +/-10% DC type: 24VDC +/-10%
Power consumption MAX 15VA MAX 8.5W MAX 11.5VA MAX 6W MAX 7.5VA MAX 3.5W MAX 6.5VA MAX 3W MAX 7.5VA MAX 3.5W
Dimensions & weight Approx. 110 (W) x 190 (H) x 54 (D) mm, Wall mounting type: 580g / Panel mounting type: 650g
Mounting Wall mounting type / Panel mounting type
  • Datasheets & User Manuals

Datasheets & User Manuals

    RM-6000 Datasheet
  • Questions & Answers

Questions & Answers

Ask a Question
  • Reviews

Reviews

RKI Instruments GH-6001 Combustible Gas Monitor, 0-500 ppm DCM (dicloromethane),100-240 VAC input, 60Hz - GH-6001A-02 $766.50 Write a Review

Related Items in This Section

  • RKI Instruments GP-6001 Combustible Gas Monitor, 0-100 %LEL Isobutane, 100-240 VAC Input - GP-6001A-01
  • RKI Instruments GP-6001 Combustible Gas Monitor, 0-100 %LEL CH4, for HW-6213 Sensor, 100-240 VAC Input - GP-6001A-02
  • RKI Instruments GH-6001 Combustible Gas Monitor, 0-200 ppm Hexane,100-240 VAC input, 60Hz - GH-6001A-01
  • RKI Instruments GH-6001 Combustible Gas Monitor, 0-500 ppm DCM (dicloromethane),100-240 VAC input, 60Hz - GH-6001A-02
  • RKI Instruments GP-6001 Combustible Gas Monitor, 0-100 %LEL H2, for HW-6211 sensor,100-240 VAC input - GP-6001A-03
  • RKI Instruments RM-6003 Gas Monitor, 0-100 %LEL isobutane, for 3-wire 4-20 mA detector, 100-240 VAC input, 60Hz - RM-6003A-01

Từ khóa » Gh-6001