Safety/Relay Unit G9SA (G9SB-301-B AC/DC24) - MiSUMi

Safety/Relay Unit G9SABrand :OMRON

Caution

Product Description

A small and ultra-thin relay unit for safety and industrial uses. The product series features a wide array of types. [Features]· Four kinds of 45-mm wide units are available: a 3-pole model, a 5-pole model, and a model with 3 poles + 2 OFF-delay poles, as well as a two-hand controller.· Also available are 17.5-mm wide expansion units with 2-poles and 3-poles, and 22.5-mm units with 3 OFF-delay poles.· The expansion units can be connected in a single action.· Can be DIN track mounted or screw mounted. OFF-delay types have 15-step OFF-delay settings.· Conforms to EN ISO13849-1 (PLe/Safety Category 4) (G9SA) and European EN standards (G9SB). TÜV certified (G9SB).· When it receives a signal from an input unit such as an emergency stop switch, it sends a signal to the output (contactor etc.) depending on whether it is judged to be safe or not. [Applications]· Can be used as device which ensures that operations only commence if it is deemed safe to do so.

Safety Relay Unit G9SA Specifications of OMRON Industrial Relays

Main ContactAuxiliary ContactNumber of Input ChannelsRated VoltageFormat
3 a1 b1 ch and 2 ch shared24 V AC/DCModel G9SA-301
100 to 240 V AC
5 a24 V AC/DCModel G9SA-501
100 to 240 V AC

Emergency stop unit of Industrial Relays

Main ContactOFF DelayContactAuxiliary ContactNumber of Input ChannelsOFF DelayTimeRated VoltageFormat
3 a2 a1 b1 ch and 2 chshared7.5 secs24 V AC/DCModel G9SA-321-T075
15 secs24 V AC/DCModel G9SA-321-T15
30 secs24 V AC/DCModel G9SA-321-T30

Emergency stop unit with OFF delay of Industrial RelaysThe OFF delay time is variable in 15 steps. The following times can be set:T075: 0.5/1/1.5/2/2.5/3/3.5/4/4.5/5/5.5/6/6.5/7/7.5 secsT15: 1/2/3/4/5/6/7/8/9/10/11/12/13/14/15 secsT30: 2/4/6/8/10/12/14/16/18/20/22/24/26/28/30 secs

Safety Relay Unit G9SB Specifications of OMRON Industrial Relays

Main ContactAuxiliary ContactNumber of Input ChannelsReset ModeInput TypeRated VoltageFormat
2 aNone2 chAutoInverse24 V AC/DCModel G9SB-2002-A
1 ch, 2 chPositive CommonModel G9SB-200-B
2 chManualInverseModel G9SB-2002-C
1 ch, 2 chPositive CommonModel G9SB-200-D
3 a1 bNo (Power supply directly OFF)Auto--24 V DCModel G9SB-3010
2 chInverse24 V AC/DCModel G9SB-3012-A
1 ch, 2 chPositive CommonModel G9SB-301-B
2 chManualInverseModel G9SB-3012-C
1 ch, 2 chPositive CommonModel G9SB-301-D
  • The Industrial Relays inverse input type is mainly used for mechanical switch 2-ch input.
  • The Industrial Relays positive common input type is mainly used for safety sensor input or for mechanical switch 1-ch input.
  • *The Model G9SB-3010 can be applied to safety category 3 because of its power supply double break.

Rating of OMRON Industrial Relays

FormatModel G9SA-301Model G9SA-501Model G9SA-321-T□
Power Supply Voltage24 V AC/DC: 24 V AC, 50/60 Hz / 24 V DC, 100 to 240 V AC: 100 to 240 V AC, 50/60 Hz
Allowable Voltage Fluctuation RangePower supply voltage -15% +10%
Power Consumption24 V AC/DC: 1.8 VA/1.7 W max.100 to 240 V AC: 9 VA max.24 V AC/DC: 2.8 VA/2.6 W max.100 to 240 V AC: 11 VA max.24 V AC/DC: 3.5 VA/3.3 W max.100 to 240 V AC: 12.5 VA max.

Power supply: G9SA type

  • *Increases by a maximum of 2 VA / 2 W when an expansion unit is connected.
FormatModel G9SB-200□-□Model G9SB-3010Model G9SB-301□-□
Power Supply Voltage24 V AC/DC: 24 V AC, 50/60 Hz / 24 DC, 24 V DC: 24 V DC
Allowable Voltage Fluctuation RangePower supply voltage -15% +10%
Power Consumption1.6 VA / 1.4 W max.1.7 W max.2.0 VA / 1.7 W max.

Power supply: G9SB type

FormatModel G9SA-301/321-T□Model G9SA-501
Input Current40 mA max.60 mA max.

Input: G9SA type

  • *Increases by a maximum of 30 mA when an expansion unit is connected.
FormatModel G9SB-200□-□Model G9SA-3010Model G9SB-301□-□
Input Current25 mA max.60 mA max.30 mA max.

Input: G9SB type

FormatModel G9SA-301/501/321-T□
LoadResistive Load
Rated Load250 V AC 5 A, 30 V DC 5 A
Rated Carry Current5 A

Switch: G9SA type

FormatModel G9SB-200□-□, Model G9SB-3010, Model G9SB-301□-□
LoadResistive Load
Rated Load250 V AC 5 A, 30 V DC 5 A
Rated Carry Current5 A

Switch: G9SB type

Performance of OMRON Industrial Relays

FormatModel G9SA-301Model G9SA-501/321-T□
Contact Resistance100 mΩ
Operating Time30 ms max.
Response Time10 ms max.
Insulation Resistance100 MΩ min., 500 V DC ohmmeter
Dielectric StrengthBetween Different Outputs2,500 V AC 50/60 Hz 1 min
Between Input and Output
Between Power Supply and Output
Between Power Supply and Input (100 to 240 V AC only)
Vibration Resistance10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock ResistanceDurability300 m/s2
Malfunction100 m/s2
DurabilityMechanical5,000,000 operations min. (at approx. 7,200 operations/hr)
Electrical100,000 operations min. (at 1,800 operations/hr under rated load)
Failure Rate (P Level) (Reference Value)5 V DC 1 mA
Ambient Operating Temperature-25 to +55°C (assuming no icing or condensation)
Ambient Operating Humidity35 to 85% RH
Terminal Tightening Torque0.98 N·m
WeightApprox. 210 gApprox. 270 g
  • Industrial Relays, Measured with 1 A at 5 V DC using the voltage-drop method.
  • Not Including bounce time.
  • The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
  • Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
  • The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.
  • The weight shown is for 24-VAC/VDC type. For 100 to 240-VAC type, add approximately 20 g.
FormatModel G9SB-200□-□Model G9SB-3010Model G9SB-301□-□
Contact Resistance100 mΩ
Operating Time30 ms max.
Response Time10 ms max.
Insulation Resistance100 MΩ min., 500 V DC ohmmeter
Dielectric StrengthBetween Different Outputs2,500 V AC 50/60 Hz 1 min
Between Input and Output
Between Power Supply and Output
Vibration Resistance10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock ResistanceDurability300 m/s2
Malfunction100 m/s2
DurabilityMechanical5,000,000 operations min. (at approx. 7,200 operations/hr)
Electrical100,000 operations min. (at 1,800 operations/hr under rated load)
Failure Rate (P Level) (Reference Value)5 V DC 1 mA
Ambient Operating Temperature-25 to +55°C (assuming no icing or condensation)
Ambient Operating Humidity35 to 85% RH
Terminal Tightening Torque0.5 N·m
WeightApprox. 115 gApprox. 135 gApprox. 120 g
  • Industrial Relays, Measured with 1 A at 5 V DC using the voltage-drop method.
  • Not Including bounce time.
  • The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
  • Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
  • The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.

Product Dimensional Outline Drawings of OMRON Industrial Relays

Units: mm

 Model G9SA-301, Model G9SA-501, Model G9SA-321-T□ full view

Model G9SA-301Model G9SA-501Model G9SA-321-T□ full view

Model G9SA-301, Model G9SA-501, Model G9SA-321-T□ dimensional outline drawing

Dimensional outline drawings of Industrial Relays

  • Time switch is only available for the Model G9SA-321-T□.
  • The K1 to K4 LEDs light when the a contacts of internal relays K1 to K4 close.
  • *Do not remove unless an expansion unit is being used.

Units: mm

Model G9SB-200□-□, Model G9SB-3010 full view

Model G9SB-200□-□Model G9SB-3010 full view

Model G9SB-200□-□, Model G9SB-3010 dimensional outline drawing

Dimensional outline drawings of Industrial Relays

Units: mm

Model G9SB-301□-□ full view

Model G9SB-301□-□ full view

Model G9SB-301□-□ dimensional outline drawing

Dimensional outline drawings of Industrial Relays

Viewed ProductsRecently Viewed ProductsMy ComponentsMy Components0CartCartEconomy SeriesMRO Product

Chat with MISUMI

Chat service is available for any inquiry to MISUMI

Service hours

9:00 - 18:00 (Mon-Sat)

For out of service hours, you can leave a message to us.We will reply to your inquiries on the next business day.(except Sundays and public holidays).

Noted for use

Chat service is for Corporate customers and limited for Thai language.

Request for Quotation and Place Order is not available on Chat.

Start chat

Từ khóa » G9sb-301-bac/dc24