 | | *Email | Email confirmation: | | *Name | | *Company | | *Phone | | *Address | | *City | | *State | | *Zip Code | | *Country | | Please answer the security question: 3+2= | | (*) Required Fields | | |  | 303-699-1135 1-800-456-9012 |  |  | - Cables & Wires
All-weather, Rubber & Welding - All-weather Cable
- Rubber & Welding Cable
Coaxial, Video & Loudspeaker - RG-Coaxial Cable
- Halogen-free RG-Coaxial Cable
- CATV-Cable
- SAT-Coaxial Cable to 2150 MHz
- Multimedia Coaxial Cable
- SAT-Coaxial Cable (Digital TV)
- Video Cable
- RGB-Transmission Cable
- Loudspeaker Cable
-
Control Cables - PUR Control Cable, Unshielded
- PUR Control Cable, Shielded
- PUR Track Cable, Unshielded
- PUR Track Cable, Shielded
- PVC Control Cable, Unshielded
- PVC Control Cable, Shielded
- PVC Track Cable, Unshielded
- PVC Track Cable, Shielded
- Bio Oil Resistant Cable
- Halogen-free Control Cable
- Safety Against High Bending - Track Cable
- Intrinsically Safe PVC Cable
Data & Computer Cables - Flexible PVC Cable
- Highly Flexible PVC Cable
Data, Network & BUS - Helucom® Fiber Optics Cable
- Helukat® Copper Data Cable
- Helukabel® BUS Cable
Flat & Ribbon Cables - Flat Cables & Ribbon Cables in PVC
Halogen-free Security Cables - Introduction
- Halogen-free Installation Cable
- Halogen-free Control Cable
- Halogen-free Data Cable
Harmonized Cable -
Harmonized Cable, VDE, UL, CSA approved Heat-Resistant & Compensating - Silicone Cable
- Fluorinated Polymeric Cable
- Single Conductor
- Multi Conductor
- Compensating Cable
Installation Cables - Installation Cables, Halogen-free
Internationally Approved - Multi-Approval Cables: UL, CSA, CE, Hookup Wire
Media Cables - Media Cables, Audio, Video, Speaker, Audio & Light
Power Cables, Medium Voltage - Power / Underground Cable & Ground Conductor
- Gas Station Cable
- Introduction: XLPE-insulated Power Cable
- Power Cables up to 30 kV, XLPE-insulated
Pre-assembled Cables - Pre-assembled Cables & Wires
Servo, Feedback & Motor Cable - Feedback Cable
- Servo Cable
- Motor Cable
- Sensor/Actuator Cable
- Robotics Cable
- Track Cable
Tray Rated Control Cables Single Conductors - PVC Single Conductor (-5°C up to +80°C)
Special Cables - Special PVC/PUR Control Cable
- Single Conductors
- Trailing Cable
- Cable for Renewable Energy
- Sensor/Actuator Cable
- Airport 400 Hz
- Truck Cable
Spiral Cable - Spiral Cables, PVC or PUR
Telephone & Fire Warning Cables - Telephone Cables & Fire Warning Cables, VDE approved
Vehicle Cables - Vehicle Cables acc. to DIN ISO 6722
- Hi-Tech Closeout Stock Sale
- TECHNICAL INFORMATION
- Advertising & Media
- Online Catalogs & Flyers
- Cable & Wire
- Enclosures
- Strain Relief
- Circular Connectors
- Conduit System
- camozzi Pneumatics
- Accessories
- Press Releases
- Cable & Wire
- Enclosures
- Strain Relief
- Circular Connectors
- Conduit System
- camozzi Pneumatics
- Accessories
- Product Videos
- Advertisements
- Blog
- Product News
- Product Applications
| | | IMPORTER OF | | | WE PROVIDE CUSTOMERS WITH CABLE MANAGEMENT SOLUTIONS! | | -Quantity Discounts! | -No Minimum Orders! | -Inventory in Excess of $25 Million! | | -Blanket Orders! | -Quick and Friendly Service! | -All Major Credit Cards! | | | | Cable Index | Harmonized Cables |  | Printable PDF | | Sealcon Helukabel Harmonized Cable: H07 RN-F | | Heavy Rubber Outer Jacket, Harmonized Type | | | | - Rubber outer jacket cable H07RN-F to DIN VDE 0282 part 4, HD 22.4 S3 IEC 60245-4
- Temperature Range -30°C to +60°C (-22°F to +140°F)
- Permissible Operating Temperature at conductor +60°C/+140°F
- Nominal Voltage U0/U 450/750 V In case of protected and fixed installation U0/U 600/1000 V
| - Max. permissible Operating Voltage in three phase and one phase a.c. system U0/U 476/825 V direct current-system U0/U 619/1238 V
- Test Voltage 2500 V
- Permanent Tensile Load Max. 15 N/mm²
- Minimum Bending Radius For fixed installation 4x cable Ø For guiding over roller 7.5x cable Ø During winding on drums 5-7x cable Ø
| | | | | No. of Conductors Selection |  | 1 |  | 2 |  | 3 |  | 4 |  | 5 |  | 7 |  | 12 |  | 18 |  | 19 |  | 24 | | | | | Helukabel Part-No. | Description & No. Conductors x cross-sec. mm2 | Outer Diameter | Cop. weight kg/km | Weight ca. kg/km | AWG | | 37001 | H07RN-F 1X1.5 | 5.7 - 7.1 | 14.4 | 58.0 | 16 | | 37002 | H07RN-F 1X2.5 | 6.3 - 7.9 | 24.0 | 71.0 | 14 | | 37003 | H07RN-F 1X4 | 7.2 - 9.0 | 38.0 | 100.0 | 12 | | 37004 | H07RN-F 1X6 | 7.9 - 9.8 | 58.0 | 130.0 | 10 | | 37005 | H07RN-F 1X10 | 9.5 - 11.9 | 96.0 | 230.0 | 8 | | 37006 | H07RN-F 1X16 | 10.8 - 13.4 | 154.0 | 290.0 | 6 | | 37007 | H07RN-F 1X25 | 12.7 - 15.8 | 240.0 | 420.0 | 4 | | 37008 | H07RN-F 1X35 | 14.3 - 17.9 | 336.0 | 530.0 | 2 | | 37009 | H07RN-F 1X50 | 16.5 - 20.6 | 480.0 | 750.0 | 1 | | 37010 | H07RN-F 1X70 | 18.6 - 23.3 | 672.0 | 960.0 | 2/0 | | 37011 | H07RN-F 1X95 | 20.8 - 26.0 | 912.0 | 1250.0 | 3/0 | | 37012 | H07RN-F 1X120 | 22.8 - 28.6 | 1152.0 | 1560.0 | 4/0 | | 37013 | H07RN-F 1X150 | 25.2 - 31.4 | 1440.0 | 1900.0 | 300 kcmil | | 37014 | H07RN-F 1X185 | 27.6 - 34.4 | 1776.0 | 2300.0 | 350 kcmil | | 37015 | H07RN-F 1X240 | 30.6 - 38.3 | 2304.0 | 2950.0 | 500 kcmil | | 37016 | H07RN-F 1X300 | 33.5 - 41.9 | 2880.0 | 3600.0 | 600 kcmil | | 37017 | H07RN-F 1X400 | 37.4 - 46.8 | 3840.0 | 4600.0 | 750 kcmil | | 37018 | H07RN-F 1X500 | 41.3 - 52.0 | 4800.0 | 6000.0 | 1000 kcmil | | 37019 | H07 RN-F 2X1 | 7.7 - 10.0 | 19.0 | 98.0 | 17 | | 37020 | H07 RN-F 2X1.5 | 8.5 - 11.0 | 29.0 | 135.0 | 16 | | 37021 | H07 RN-F 2X2.5 | 10.2 - 13.1 | 48.0 | 193.0 | 14 | | 37022 | H07 RN-F 2X4 | 11.8 - 15.1 | 77.0 | 280.0 | 12 | | 37023 | H07 RN-F 2X6 | 13.1 - 16.8 | 115.0 | 330.0 | 10 | | 37024 | H07 RN-F 2X10 | 17.7 - 22.6 | 192.0 | 586.0 | 8 | | 37025 | H07 RN-F 2X16 | 20.2 - 25.7 | 307.0 | 810.0 | 6 | | 37026 | H07 RN-F 2X25 | 24.3 - 30.7 | 480.0 | 1160.0 | 4 | | Helukabel Part-No. | Description & No. Conductors x cross-sec. mm2 | Outer Diameter | Cop. weight kg/km | Weight ca. kg/km | AWG | | 37027 | H07RN-F 3G1 | 8.3 - 10.7 | 29.0 | 130.0 | 17 | | 37028 | H07RN-F 3G1.5 | 9.2 - 11.9 | 43.0 | 165.0 | 16 | | 37029 | H07RN-F 3G2.5 | 10.9 - 14.0 | 72.0 | 235.0 | 14 | | 37030 | H07RN-F 3G4 | 12.7 - 16.2 | 115.0 | 320.0 | 12 | | 37031 | H07RN-F 3G6 | 14.1 - 18.0 | 173.0 | 420.0 | 10 | | 37032 | H07RN-F 3G10 | 19.1 - 24.2 | 288.0 | 810.0 | 8 | | 37033 | H07RN-F 3G16 | 21.8 - 27.6 | 461.0 | 1050.0 | 6 | | 37034 | H07RN-F 3G25 | 26.1 - 33.0 | 720.0 | 1250.0 | 4 | | 37035 | H07RN-F 3G35 | 29.3 - 37.1 | 1008.0 | 1900.0 | 2 | | 37036 | H07RN-F 3G50 | 34.1 - 42.9 | 1440.0 | 2600.0 | 1 | | 37037 | H07RN-F 3G70 | 38.4 - 48.3 | 2016.0 | 3400.0 | 2/0 | | 37038 | H07RN-F 3G95 | 43.3 - 54.0 | 2736.0 | 4450.0 | 3/0 | | 37039 | H07RN-F 3G120 | 47.4 - 60.0 | 3456.0 | 5180.0 | 4/0 | | 37040 | H07RN-F 3G150 | 52.0 - 66.0 | 4320.0 | 6500.0 | 300 kcmil | | 37041 | H07RN-F 3G185 | 57.0 - 72.0 | 5328.0 | 7860.0 | 350 kcmil | | 37042 | H07RN-F 3G240 | 65.0 - 82.0 | 6192.0 | 10224.0 | 500 kcmil | | 37043 | H07RN-F 3G300 | 72.0 - 90.0 | 8640.0 | 12620.0 | 600 kcmil | | 37044 | H07 RN-F 4G1 | 9.2 - 11.9 | 38.0 | 150.0 | 17 | | 37045 | H07 RN-F 4G1.5 | 10.2 - 13.1 | 58.0 | 200.0 | 16 | | 37046 | H07 RN-F 4G2.5 | 12.1 - 15.5 | 96.0 | 290.0 | 14 | | 37047 | H07 RN-F 4G4 | 14.0 - 17.9 | 154.0 | 395.0 | 12 | | 37048 | H07 RN-F 4G6 | 15.7 - 20.0 | 230.0 | 540.0 | 10 | | 37049 | H07 RN-F 4G10 | 20.9 - 26.5 | 384.0 | 950.0 | 8 | | 37050 | H07 RN-F 4G16 | 23.8 - 30.1 | 614.0 | 1260.0 | 6 | | 37051 | H07 RN-F 4G25 | 28.9 - 36.6 | 960.0 | 1860.0 | 4 | | 37052 | H07 RN-F 4G35 | 32.5 - 41.1 | 1344.0 | 2380.0 | 2 | | 37053 | H07 RN-F 4G50 | 37.7 - 47.5 | 1920.0 | 3190.0 | 1 | | 37054 | H07 RN-F 4G70 | 42.7 - 54.0 | 2688.0 | 4260.0 | 2/0 | | 37055 | H07 RN-F 4G95 | 48.4 - 61.0 | 3648.0 | 5600.0 | 3/0 | | 37056 | H07 RN-F 4G120 | 53.0 - 66.0 | 4608.0 | 6830.0 | 4/0 | | 37057 | H07 RN-F 4G150 | 58.0 - 73.0 | 5760.0 | 8320.0 | 300 kcmil | | 37058 | H07 RN-F 4G185 | 64.0 - 80.0 | 7104.0 | 9800.0 | 350 kcmil | | 37059 | H07 RN-F 4G240 | 72.0 - 91.0 | 9216.0 | 12100.0 | 500 kcmil | | 37060 | H07 RN-F 4G300 | 80.0 - 101.0 | 11520.0 | 15200.0 | 600 kcmil | | Helukabel Part-No. | Description & No. Conductors x cross-sec. mm2 | Outer Diameter | Cop. weight kg/km | Weight ca. kg/km | AWG | | 37061 | H07RN-F 5G1.5 | 11.2 - 14.4 | 72.0 | 240.0 | 16 | | 37062 | H07RN-F 5G2.5 | 13.3 - 17.0 | 120.0 | 345.0 | 14 | | 37063 | H07RN-F 5G4 | 15.6 - 19.9 | 192.0 | 485.0 | 12 | | 37064 | H07RN-F 5G6 | 17.5 - 22.2 | 288.0 | 650.0 | 10 | | 37065 | H07RN-F 5G10 | 22.9 - 29.1 | 480.0 | 1200.0 | 8 | | 37066 | H07RN-F 5G16 | 26.4 - 33.3 | 768.0 | 1550.0 | 6 | | 37067 | H07RN-F 5G25 | 32.0 - 40.4 | 1200.0 | 2250.0 | 4 | | 37068 | H07RN-F 5G35 | 36.8 - 45.8 | 1680.0 | 2750.0 | 2 | | 37091 | H07RN-F 5G50 | 40.0 - 50.8 | 2400.0 | 3950.0 | 1 | | 37092 | H07 RN-F 7G1.5 | 14.5 - 17.5 | 101.0 | 375.0 | 16 | | 37079 | H07 RN-F 7G2.5 | 16.5 - 20.0 | 168.0 | 520.0 | 14 | | 37093 | H07 RN-F 12G1.5 | 17.6 - 22.4 | 175.0 | 460.0 | 16 | | 37096 | H07 RN-F 12G2.5 | 20.6 - 26.2 | 288.0 | 760.0 | 14 | | 37097 | H07 RN-F 18G2.5 | 24.4 - 30.9 | 432.0 | 850.0 | 14 | | 37094 | H07 RN-F 19G1.5 | 20.7 - 26.3 | 274.0 | 810.0 | 16 | | 37098 | H07 RN-F 19G2.5 | 25.5 - 31.0 | 456.0 | 1075.0 | 14 | | 37095 | H07RN-F 24G1.5 | 24.3 - 30.7 | 346.0 | 1015.0 | 16 | | 37099 | H07RN-F 24G2.5 | 28.8 - 36.4 | 576.0 | 1390.0 | 14 | | | to top  | | Current ratings for H07 RN-F (H07RN-F) for current supply in industrial application Operating temperature at conductor +60°C/+140°F, ambient temperature +30°C/+86°F (Air) | | | Number of Conductors | 1-conductor | 2-conductor | 3-conductor | 3-conductor | 4-conductor | 5-conductor | | Number of loaded conductors | 2 loaded | 3 loaded | 2 loaded | 2 loaded | 3 loaded | 3 loaded | 3 loaded | | Cross-section in mm2 | Current ratings in Ampere | | 4 | 34 | 30 | 34 | 35 | 29 | 30 | 30 | | 6 | 43 | 38 | 43 | 44 | 36 | 37 | 38 | | 10 | 60 | 53 | 60 | 62 | 51 | 52 | 54 | | 16 | 79 | 71 | 79 | 82 | 67 | 69 | 71 | | 25 | 104 | 94 | 105 | 109 | 89 | 92 | 94 | | 35 | 129 | 117 | - | 135 | 110 | 114 | - | | 50 | 162 | 148 | - | 169 | 138 | 143 | - | | 70 | 202 | 185 | - | 211 | 172 | 178 | - | | 95 | 240 | 222 | - | 250 | 204 | 210 | - | | 120 | 280 | 260 | - | 292 | 238 | 246 | - | | 150 | 321 | 300 | - | 335 | 273 | 282 | - | | 185 | 363 | 341 | - | 378 | 309 | 319 | - | | 240 | 433 | 407 | - | 447 | 365 | 377 | - | | 300 | 497 | 468 | - | 509 | 415 | 430 | - | | 400 | 586 | 553 | - | - | - | - | - | | 500 | 670 | 634 | - | - | - | - | - | | 630 | 784 | 742 | - | - | - | - | - | | | to top  | | Note | | For the method of installation | - Single conductor cables are bunched
| - 2-conductor cables laid parallel with contact
| - 3-conductor cables are in triangle-form
| | Conversion factors for deviating ambient temperature | | Ambient temperature at air °C/°F | 30/86 | 35/95 | 40/104 | 45/113 | 50/122 | 55/131 | | Factor | 1.0 | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 | | | | We can also have your company name printed on these cables. |  | | Cable Construction | to top  | | - Copper conductor fine wire stranded, bare to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383
- Rubber conductor insulation EI4 to DIN VDE 0282 part 1
- Insulation thickness to DIN VDE 0282 part 4
- Conductor identification to DIN VDE 0293-308 and HD 186
- Conductor colors up to 5 conductors - one color 6 and more conductors - black with numbering 3 and above - with green-yellow earth conductor 2 conductors without green-yellow grounding conductor
- Conductors stranded in layers with optimal lay-length
- Outer jacket (rubber): Black, rubber compound to DIN VDE 0282 part 1
- Jacket thickness to DIN VDE 0282 part 4
| | | Properties | to top  | | - Resistant to Ozone Weather
- Oil resistant Test according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
- Ozone resistant of the insulation to DIN VDE 0472 part 805, test method A or part 805 A1, test method C
- Oil resistant - Test according to EN 60811-2-1
| | | Note | to top  | | - G = with green-yellow ground conductor x = without green-yellow ground conducto.
- AWG sizes are approximate equivalent values. The actual cross-section is in mm².
- Further dimensions and cross-sections available upon request
- H07 RN-F = harmonized cable with rubber outer jacket, working voltage 750V, fine stranded
- The core identification of a single core jacketed insulated wire is black. For application as a protective conductor, the ends are to be identified with green-yellow and the middle conductor with light blue.
| | | Application | to top  | Heavy duty rubber-outer jacket flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open air and in agriculture plants. They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws and tools for home use as well as for transportable motors or machines at site. These cables are also suitable for fixed installation on plaster, in temporary buildings and residential barracks. They are suitable for direct laying on components and mechanical parts of machines, for example lifts and cranes. They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage up to 1000 V alternating voltage or a direct voltage up to 750 V against ground. The operating direct voltage is permitted up to 900 V against ground when they are used in rail-coaches. Installation in hazardous areas according to DIN VDE 0165 is allowed. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. | | | | | | Items For Quote Update Easy Quote | Harmonized Cables | FIVENORM | | H03VV-F | | H05VV-F: Black / White | | H05VV-F: Gray / Orange | | H05VV-F/SJT: Black / Gray | | H05VV-F/SJT: Orange | | H07 RN-F | | H07 G-U (Solid Conductor) | | H07 G-R (Stranded Conductor) | | H07 G-K | | JZ-603 | | JZ-603-CY | | THREENORM |  | | | is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry. | Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands Threads: PG, NPT, Metric, BSPP Threads Materials: Nylon, Nickel Plated Brass, PVDF (for chemicals and extreme temperatures) & Stainless Steel, NEMA 4x and 6 (IP68, IP 69K). Approvals: RoHS, Deca BDE, UR, UL, CE, CSA, VDE, German Lloyd, etc. UL f1 (UL 746C) - Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C | Circular Connectors (M16, M23, RJ45, M27 and M40) Sizes: M16 Signal, M23 Signal & Power, M27 Signal, M40 Power, M12/16 Twintus Types: Twintus, RJ45 Industrial Ethernet, PoE Fast Ethernet, Push-Pull, Stainless Steel, Over Molded Cordsets, Standard/EMI Ready Configurations: Signal (3-28 pole) & Power (6 & 8 pole) Materials: Nickel Plated Brass, Stainless Steel and Aluminum Approvals: RoHS, Deca BDE, UR, UL, CSA, TÜV, etc. | Industrial Enclosures (Plastic & Metal) Materials: Polycarbonate, ABS (Acryl-Butadiene-Styrene), Aluminum, Steel/Stainless Steel and Polyester. Types: Gray or Transparent Lids, available with Hinges and Latches, Plain Walls or Knockouts. Approvals: RoHS, Deca BDE, UL, CSA, TUV and CE. Modular, Expandable, UV and Impact Resistant, NEMA 4, 4x (IP 66/67). Solar Plus for Photovoltaic applications. Our Enclosures can be equipped with Strain Relief Fittings, Circular Connectors or Conduit Fittings. Other customization options like cutting & drilling are also available. | Conduit System High Pull-Out Resistance, Robust Performance, Long Life Expectancy, Fastest/ Easy installation, No Tools required! Fittings: Push-In, Turn-to-Seal, Snapclic DUO (Nylon or Nickel Plated Brass), Double-Seal, Flange/Bulkhead Conduit: Standard and Super Flex Corrugated Conduit Accessories: Snap-In Mounting Brackets. NEMA 4 (IP 54/65) Approvals: RoHS, Deca BDE, UR, German Lloyd, CE, etc. | Hazardous Location / Explosive Proof Cord Grips, Cable Glands These fittings are labeled and approved to withstand the required needs of a combustible environment. Materials: Nylon, Nickel Plated Brass, PVDF (chemical resistant & extreme temperatures), Stainless Steel. Threads: NPT, Metric & PG. NEMA 4x (IP 67) and 6 (IP 68/69K) Approvals: RoHS, Deca BDE, UL, CSA, VDE, CE, EEx e, ATEX, German Lloyd, IECEx, Ex-d/Ex-e, Ex-i EXIOS - High-end Cable Glands for armored cables in hazardous areas including the latest IECEx and ATEX certifications, for use in Ex-e, Ex-d and Ex-tD areas | Thread Adapters, Enlargers, Reducers Convert, Increase or Decrease your thread size with our newest product line of Adapters, Enlargers and Reducers. Threads: NPT, Metric and PG. Materials: Black or Gray Nylon, Nickel Plated Brass, Aluminum, Stainless Steel. Approvals: RoHS, Deca BDE, CE, EEe x, ATEX, etc. Hazardous / Explosive proof versions available. | Cable Accessories Locking Nuts:Black & Gray Nylon, Nickel Plated Brass, Zinc Plated Steel, EMI (w/ Cutting Edges) O-Rings: Buna-N, Viton®, Silicone Seal Rings: Polyethylene / Fiber-reinforced Plastic Hole Plugs: Dome, Hex, Nylon, Nickel Plated Brass Inserts: Standard, Reduced, Multi-Hole, Romex® Other Accessories: Ratchet & Socket Wrenches, Cable Clamps, etc. | | |