Model | IX-H2000 | |||
Main unit / expansion unit | Main unit | |||
Display | Min. display unit | Z axis | 10 μm *1 | |
X axis | 50 μm *1 | |||
Display range | Z axis | ±999.99 to ±999 mm 39.33" (with 4 selectable steps) *1 | ||
X axis | ±999.95 to ±999 mm 39.33" (with 4 selectable steps) *1 | |||
Tools | Scan mode | Height, Step, Average height, Pin height, MAX/MIN, Height area, Monochrome area, Width, Step calculation, Thickness calculation,Position adjustment, 1-axis adjustment, 2-axis adjustment (Max. number of settings) Judgment: 16 tools, Position adjustment: 1 tool*2 | ||
Line mode | Height (Ave./Max./Min.), Step (Ave./Max./Min.), Edge position, Width/diameter, Step/width calculation, Thickness calculation,Position adjustment, Tilt adjustment (Max. number of settings) Judgment: 16 tools *3, Position adjustment: 1 tool, Tilt adjustment: 1 tool*2 | |||
Other functions | Common | Zero/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR),Sensor date/time information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgment conditions, NPN/PNP switching,Simultaneous main unit/expansion unit input, Mutual interference prevention, Security | ||
Scan mode | Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain),Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram,Area height histogram, Fixed reference area, Mask outline, Rotation range, Height image display on tool setting screen, Scaling function | |||
Line mode | Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement,HOLD function, Alarm setting, Measurement method (Ave./Max./Min.), Laser sensitivity adjustment, Averaging filter, Median filter, X-axis median filter | |||
Input | Input | Switchable between non-voltage input and voltage inputFor non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) | ||
Number of inputs | 8 (IN1 to IN8) | |||
Function | IN1: External trigger ↑↓ / Timing input, IN2 to IN8: Enable by assigning optional functionsAssignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgment value only) Reset (judgment value and error) | |||
Output | Output | Open collector output; NPN/PNP switchable, N.O./N.C. switchableFor open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or lessFor open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less | ||
Number of inputs | 10 (OUT1 to OUT10) | |||
Function | Enable by assigning the optional functionsAssignable functions: Total judgment result (All OK/Any OK/NG), Run, Busy, Error, Position adjustment result, Tilt adjustment result, Result of the logical operation of each tool,Monochrome area / Height area tool result (OK/NG), Height / Step / Max./Min. / Calculation tool result (OK/NG/HIGH/LO), Alarm | |||
Analog voltage output | ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω *4 | |||
Analog current output | 4 to 20 mA, Max. load resistance: 350 Ω *4 | |||
Number of programs | 32 | |||
Statistical information | Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1 *5 | |||
Detection history | Saved history | Scan mode | 50 (FTP/SFTP client function: Enabled/High-resolution mode: Enabled)80 (FTP/SFTP client function: Enabled/High-resolution mode: Disabled)70 (FTP/SFTP client function: Disabled/High-resolution mode: Enabled)100 (FTP/SFTP client function: Disabled/High-resolution mode: Disabled) *6 | |
Line mode | 400 (FTP/SFTP client function: Enabled/High-resolution mode: -)500 (FTP/SFTP client function: Disabled/High-resolution mode: -) *6 | |||
Save conditions | Selectable between NG only and All *6 | |||
Image data transmission (FTP/SFTP client function) | Destination | FTP/SFTP server | ||
Method | Selectable between bmp, jpeg, and txt | |||
Conditions | 4 conditionsSelectable between All, Total judgment result (OK/NG), Result of each tool (OK/(NG and ALM)), and Result of the logical operation of each tool (OK/NG) | |||
Ethernet | Standard | 100BASE-TX/10BASE-T *7 | ||
Connector | RJ45 8-pin connector *7 | |||
Interface compatibility | CC-Link, DeviceNet®, EtherNet/IP™, EtherCAT®, RS-232C, BCD output, TCP/IP non-procedural communication *8 | |||
Number of connectible units | Main units: 1, Expansion units: 1, Communication units (DL): 1 | |||
Ratings | Power voltage | 24 VDC ±10% (including ripple) | ||
Current consumption | Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *9 | |||
Environmental resistance | Ambient temperature | 0 to +50°C 32 to 122°F (No freezing) | ||
Relative humidity | 35 to 85% RH (No condensation) | |||
Material | Main unit case: PC / Power connector: PA, POM / Analog output connector: PA, POM / I/O connector: PA /Head connector: Zinc + Ni plating, PA / Ethernet connector: Copper alloy + Ni plating / Rear heat sink:Aluminum / Main unit rear DIN rail fixing tab: POM / Nameplate: PC | |||
Weight | Approx. 210 g | |||
*1 For displaying on an IX Series control panel or PC software.*2 Configurable for each program.*3 Up to 8 tools can be used for the diameter tool only.*4 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.*5 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.*6 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software.*7 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.*8 When a DL Series device is used. Contact KEYENCE for information on other interfaces.*9 Includes a DL Series communication unit. | ||||
Scroll
Data Sheet (PDF) Other Models
View Catalog
Downloads:
- Technical Guides
- Data Sheet (PDF)
- CAD / CAE
- Manuals
- Software
For Your Support:
- Ask an Expert
- Experience Demo / Test
- Free Trial Unit
Product Lineup:
- Laser Displacement Sensors
- Home
- Products
- Measurement Sensors
- Laser Displacement Sensors
- Image-Based Laser Sensor
- Models
- Sensor amplifier main unit
- Catalogs
- CAD / CAE
- Manuals
- Software
- Data Sheet (PDF)
- Price
- Experience Demo / Test
- Ask an Expert
Từ khóa » H 2000
-
Luxury Rooms H 2000 Roma
-
VECTASHIELD® PLUS Antifade Mounting Medium With DAPI
-
H 2000 | Ellison Technologies
-
PortaCom H2000 Dual-Earpiece Headset H-2000 B&H Photo Video
-
HDK® H2000 | Pyrogenic Silica - Wacker Chemie AG
-
H-2000 PEM Fuel Cell - 2kW - Horizon Educational
-
[PDF] H-2000-2014-06-B (RP3 Data Sheet).pmd - Renishaw
-
H2000 / ROV / Remotely Operated Vehicle - ECA Group
-
Phân Bón Lá H-2000.L 100ml
-
Characterization Of The Decision-making Deficit Of Patients With ...
-
H2000 Spraygun Mini HVLP - YouTube
-
Gusmer H-2000 Manuals - Polysource Industries
-
Economy Chain Hoists With Chain Container - Product Page