Siderise CW-FS Firestop - Flip EBook Pages 1-28 - AnyFlip

  • Quick Upload
  • Explore
  • Features
  • Support
    • Contact Us
    • FAQ
    • Help Document
  • Pricing
Sign In Sign Up
  • Explore
  • Features
  • Support
    • Contact Us
    • FAQ
    • Help Document
  • Pricing
  • Enrichment
  • Business
  • Books
  • Art
  • Lifestyle
  • Religion
  • Home
  • Science
The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here. Home Explore Siderise CW-FS Firestop View in Fullscreen

Siderise CW-FS Perimeter Barriers & Firestop

Like this book? You can publish your book online for free in a few minutes!
  • Kencana Mirae Industri
  • http://anyflip.com/moult/lttv/
Download PDF Share

Related Publications

Discover the best professional documents and content resources in AnyFlip Document Base. Search Published by Kencana Mirae Industri, 2021-10-21 22:35:45 Siderise CW-FS Firestop
    Pages:
  • 1 - 28

Siderise CW-FS Perimeter Barriers & Firestop

VERSION 1.9 SEPTEMBER 2021PERIMETERBARRIERS &FIRESTOPSFor use in curtain wallingapplications2 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSPERIMETER BARRIERS Siderise CW perimeter barrier and fire stop systemsAND FIRE STOPS FOR offer an extensive range of solutions for fire stop, smokeCURTAIN WALLING stop and sound barrier requirements in all architectural cladding panel applications. Based on the experience gained through being the premier supplier to the UK curtain walling market, the products represent an unrivalled combination of fully qualified performance, practical installation and service benefits. The primary function of the CW system is to maintain continuity of fire resistance by sealing the void between the compartment floors or walls and the external curtain wall both horizontally and vertically.Canary Wharf, LondonFront Cover: Dollar Bay, London• No. 1 in the UK for over 30 years | 3VERSION 1.9 SEPTEMBER 2021• Third-party approved options: Benefits Certifire & Intertek certification• Fully compliant to: UK, EU & UAE regulations • Market leading fire resistance and smoke seal• Fire Resistance to: EN 1364-4, EN 1366-4 • Suitable for horizontal and vertical application• Classified ‘A1‘ to: EN 13501-1 • Unique product construction provides ability to accommodate façade movement • Fully qualified acoustic performance • Simple and quick to install4 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSPRODUCT DESCRIPTIONSiderise perimeter barriers and fire stops for curtainwalling use is a unique method of manufacture thatprovides a resilient lateral compression. This facilitatesinstallation ensuring the requisite tight fit and enhancesfire integrity.The materials throughout the range comprise of a one-piece product with a pre-compressed non-combustiblestone wool core. The products also have integralaluminium foil facings to provide an overall Class A1 rating(to EN 13501-1) and excellent resistance to smoke.The systems can offer tested fire rating options rangingfrom 30mins to 3 hours and can accommodate voidwidths up to 600mm.In addition to providing an effective seal against thepassage of smoke and fire the products will also functionas an effective acoustic barrier and plenum lining. Siderise Cavity Barrier (CW-CB) or Siderise Fire Stop (CW-FS) Metal spandrel panel with Siderise Nexus ‘Core’ Siderise Nexus ‘Fusion’ Insulation other than Class A1 Siderise Nexus or Class A1 Siderise CW-FB Curtain Wall Fire Board Siderise CW-AB Acoustic Barrier Overlay Siderise CVB/C Acoustic Void Barrier| 5VERSION 1.9 SEPTEMBER 2021Standard systems Fire performance Third party certificationThe materials can be either supplied Reaction to fire Certifire Certification has beenas pre-cut units to suit a specified void achieved based on proven firesize or in sheet form for cutting on Siderise CW Cavity Barriers and Fire performance, for horizontalsite. Stops have been tested for non- applications to EN 1364-4 (Table 1), combustibility and classified ‘A1’ to EN and horizontal and vertical applicationsSheets 13501-1. to EN 1366-4 (Table 2 & 3).• Standard sheet products are Resistance to fire For further details, Certifire Certificate supplied 1200 x 1200mm which may ‘CF 563’ can be downloaded from prove beneficial when the actual Siderise CW systems have been tested www.siderise.com void size is not known or where to EN 1364-4 and EN 1366-4 for fire it varies significantly. Please note resistance, and classified to EN 13501- Intertek Certification has also been when ordered in sheet form, the 2. achieved based on reaction to fire requisite quantity of fixing brackets performance to EN 13501-1, and fire needs to be purchased separately. Siderise CW systems provide resistance to EN 1364-4 for horizontal continuity of fire resistance applications (Table 1).Pre-cut Strips across the void when aligned with• Pre-cut products are available in fire rated elements to maintain For further details, Intertek compartmentation. Certificates ‘WH120-32944302’ 1mm increments of width to suit the (EN 13501-1) and ‘WHI19-32944301’ cavity size. Please see Tables 1, 2 & 3 The correct system is simply selected (EN 1364-4) can be downloaded from regarding ‘fit type’. by matching the fire resistance www.siderise.com. requirements to the CW system type• S upplied with appropriate brackets and void size. as part of a system Tables 1 to 3 summarise the voidThe standard fixing brackets are sizes, fire resistance classificationssupplied in 1mm galvanised mild steel to EN 13501-2, and provide 3rd Partyin flat form that is complete with a pre- Certification details where applicable.notched facility for folding on site. Approved Document B – England &All holes are to be drilled to suit the Walesvarying site conditions. Different sizebrackets are available according to the Approved Document B for Englandcavity size – please see Tables 1 to 3. & Wales (2019 edition) gives classification to EN 13501-2 as theAll fixing brackets are to be mechanic- primary route to compliance.ally secured to the substructure withsuitable non-combustible fixings. BS 476-20 remains as an alternate route to compliance. Siderise CW systems have addition- ally been tested and assessed to BS 476-20. For any voids not covered by Tables 1 to 3, please contact technical. [email protected] for advice on these options.6 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSTable 1: Fire Resistance to EN 1364-4* (Horizontal Orientation)Void Product Product Compression Cover Bracket Classification 3rd Party ApprovalWidth Ref. Thickness (minimum) Length Requirement (EN 13501-2)(mm) Certifire ‘CF 563’ (mm) 2 no. B65/110 EI 120 Intertek ‘WHI19-20 to 50 600mm EI 180 32944301’ CW-FS120 120mm +10% 1200 centres EI 120 Certifire ‘CF 563’51 to 150 CW-FS180 150mm 2 no. B65/110 EI 180 Intertek ‘WHI19- 600mm EI 120 32944301’151 to CW-FS120 120mm +10% 1200 centres EI 180 Certifire ‘CF 563’250 CW-FS180 150mm 2 no. B195 Intertek ‘WHI19- 600mm 32944301’ CW-FS120 120mm +10% 1200 centres CW-FS180 150mmNOTE: All fixing brackets are to be mechanically fixed to structure. Please see separate installation instructions.Table 2: Fire Resistance to EN 1366-4 (Horizontal Orientation)Void Product Product Compression Cover Bracket Classification 3rd Party ApprovalWidth Ref. Thickness (minimum) Length Requirement (EN 13501-2) Certifire ‘CF 563’(mm) Certifire ‘CF 563’ (mm) None EI 30 Certifire ‘CF 563’ EI 60 Certifire ‘CF 563’ CW-CB30 75mm 2 no. B65/110 EI 120 Certifire ‘CF 563’ 600mm EI 3020 to 50 CW-FS60 90mm +10% 1200 centres EI 60 2 no. B195 EI 120 CW-FS120 120mm 600mm EI 30 centres EI 60 CW-CB30 75mm 2 no. B355 EI 120 600mm EI 3051 to 150 CW-FS60 90mm +10% 1200 centres EI 60 2 no. B355 EI 120 CW-FS120 120mm 600mm centres EI 60 CW-CB30 75mm151 to 250 CW-FS60 90mm +10% 1200 CW-FS120 120mm251 to CW-CB30 75mm +10% 1200300 CW-FS60 90mm CW-FS120 120mm301 to CW- 120mm +10% 1200600 FS60-XNOTE: All fixing brackets are to be mechanically fixed to structure. Please see installation instructions.| 7VERSION 1.9 SEPTEMBER 2021Table 3: Fire Resistance to EN 1366-4 (Vertical Orientation)Void Product Product Compression Cover Bracket Classification 3rd Party ApprovalWidth Ref. Thickness (minimum) Length Requirement (EN 13501-2) Certifire ‘CF 563’(mm) Certifire ‘CF 563’20 to 50 (mm) None EI 30 Certifire ‘CF 563’ EI 60 Certifire ‘CF 563’51 to 150 CW-CB30 75mm +10% 1200 2 no. B65/110 EI 120 Certifire ‘CF 563’ CW-FS60 90mm 600mm EI 30 Certifire ‘CF 563’151 to CW-FS120 120mm +10% 1200 centres EI 60250 CW-CB30 75mm 2 no. B195 EI 120 CW-FS60 90mm +10% 1200 600mm EI 30251 to CW-FS120 120mm centres EI 60300 CW-CB30 75mm +10% 1200 2 no. B355 EI 120 CW-FS60 90mm 600mm EI 30301 to CW-FS120 120mm +10% 1200 centres EI 60450 CW-CB30 75mm 2 no. B355 EI 120451 to CW-FS60 90mm 600mm EI 30600 CW-FS120 120mm centres EI 60 CW-CB30 75mm 2 no. B355 EI 120 CW-FS60 90mm 600mm CW-FS120 120mm centres EI 60 CW- 120mm +20mm 1200 FS60-XNOTE: All fixing brackets are to be mechanically fixed to structure. Please see installation instructions.8 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSAcoustic performance As an example, the installation of which can further enhance the 120mm thick CW-FS120 within the overall acoustic performance of theThe CW range additionally provides an cavity will increase the transmission construction.effective sound barrier as the material loss via the tortuous sound path byconstruction and inherent properties approximately 25dB. AB barriers are extremely quick andof the stone wool core afford the CW easy to install and are suitable forexceptional acoustic performance. The precise value will depend upon improving sound performance within the specifics of the construction. all curtain walling environments.Also, the foil facings coupled withthe additional sealing of joints with Table 4 confirms values for Weighted The AB acoustic barriers are factorySiderise foil tape all serve to provide Sound Reduction Index (Rw) based on produced multi-layer compositeimproved air tightness. laboratory tests to determine airborne materials consisting of an aluminium sound transmission in accordance with foil faced polymeric layer bonded to aSound reduction between floors BS EN ISO 140-3 : 1995, BS 2750 Pt 3 flexible acoustic foam. The productsThe installation of the CW systems :1995. are available in two grades dependingwithin an external curtain wall cavity on the acoustic performancewill significantly increase the floor-to- Enhanced acoustic performance requirement, namely AB5 and AB10floor attenuation. AB acoustic barriers whenever façade deflection is Siderise offer a range of complementary anticipated. acoustic mass overlay materialsTable 4: CW acoustic performance Table 5: AB acoustic performanceWeighted Sound Reduction Index Weighted Sound Reduction IndexProduct Type Thickness (mm) Rw (dB) Product Type Surface mass (mm) Rw (dB)CW-CB30 75 21 25 22 AB5 5 kg/m2 28 25CW-FS60 90 26* AB10 10 kg/m2CW-FS120 120CW-FS180 150NOTE: *Assessed values by either UKAS accredited Laboratoriesor IOA registered Acoustic EngineersTable 6: The table below illustrates typical CW and AB acoustic performance of a range of different curtain wallfire stopping products, including products manufactured by Siderise.Product 21 - 30dB Rw 31 – 35dB Rw 36 - 50dB Rw 50dB Rw + Rw RwSiderise CW-FS60 Rw Rw Rw Rw Rw RwSiderise CW-FS120 + Ctr + Ctr + Ctr + CtrSiderise CW-FS60 + AB5 Overlay 23 21 — — — — ——Siderise CW-FS120 + AB5 Overlay 25 23 — — — — ——Siderise CW-FS60 + AB10 Overlay — — 33 27 — — ——Siderise CW-FS120 + AB10 Overlay — — 33 27 — — ——Siderise CW-FS120 + AB10 Overlay — — — — 36* 31* ——+ CVB/C10 below — — — — 37 32 ——Siderise CW-FS120 + 2mm Steel Plate Overlay —+ CVB/C10/75 below —— —— — 51 45 — —— —— — 53 45NOTE: *Assessed values by either UKAS accredited Laboratories or IOA registered Acoustic Engineers| 9VERSION 1.9 SEPTEMBER 2021Siderise CW-FS120 Siderise CW-FS120 + AB10 Overlay Siderise CW-FS120 + AB10 Overlay + CVB/C10 belowSociete Generale, London10 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS| 11VERSION 1.9 SEPTEMBER 2021Installation recommendations Where the void is smaller than the Installation detailing section available, the CW-CB/CW-FSSiderise CW is installed using can be trimmed on site with a sharp For the interface with the mullionnecessary compression and fixing serrated knife providing that the condition we recommend that thebrackets (see tables 1-3) which are compression allowance is maintained. CW is trimmed to accommodateimpaled into the material at mid- Also, if used in sheet form, the product the mullion with the joint betweenthickness at nominal 600mm fixing must be cut to provide the requisite adjacent product being along thecentres i.e. 300mm from each end. compression fit. centre line of the mullion.For horizontal applications the cut Installation principles For curtain wall systems with mullionstrips are then inserted within the void centres in excess of 1200mm, wewith the fixing brackets located over The CW material must be installed recommend the use of standardthe edge of the concrete floor slab. with the un-faced stone wool in 1200mm CW-CB/CW-FS trimmed to contact with the sides of the cavity, accommodate the mullion, togetherThe brackets must be mechanically the aluminium foil smoke barrier with a smaller section of CW-CB/fixed to the compartment floor or wall, facings will be positioned top and CW-FS trimmed to accommodate thewith suitable non-combustible fixings. bottom i.e. remains visible to the mullion. installer. For all installations the CWThe CW is built into the void to seals are to be sized to provide the Please note that the smaller 300mmprovide the necessary compression as correct compression allowance. See CW-CB/CW-FS length is secured withper Tables 1 to 3. It’s crucial that there Tables 1 to 3. two fixing brackets. We specify that allare no gaps. small portions of CW-CB/CW-FS are Installation considerations fixed with two fixing brackets as partEnsure that there are no gaps and that of the system.all joints, including the intersections As standard, the CW material must beof horizontal / vertical installation, compressed within the void to maintain For the interface with the spandrelare tightly abutted and sealed with the integrity of the seal. panel at the mullion position weSiderise foil tape to ensure the recommend the use of a cut portionintegrity of the smoke barrier. As a For vertical applications where the of CW product to suit the void (cutminimum the topside is only sealed façade deflection may be up to 15mm, oversize to maintain compression).with Siderise foil tape, the juncture we recommend that you calculate This is then bonded into position withbetween façade and floor or wall need the design deflection of the external Siderise fire and acoustic gap sealant.not be sealed. façade system in both positive and negative wind load situations. Then Smaller voids and/or particularlyFixing brackets follow Tables 1 to 3 + the design difficult situations can be treated by deflection of the system. the additional application of SideriseA range of support brackets for fire and acoustic gap sealant to makeSiderise CW-FS horizontal perimeter Additional material allowances good joints, areas of missing materialbarriers are available for void widths should be included whenever façade or complex details.of up to 600mm (see Tables 2 and 3 deflection is anticipated. For example:for appropriate type and quantity). The CW material is easily cut on site CW-CB/CW-FS + Deflection + with a sharp serrated knife to formThe fixing brackets should be trimmed Compression a tight resilient seal around mullionif necessary to approximately 75% details and structural brackets etc.of the cavity width. The standard CW-CB/CW-FS to suit void + 15mmfixing brackets are supplied in 1mm + 10mm = CW-CB/CW-FS to suit voidgalvanised mild steel in flat form that + 25mmis complete with a pre-notched facilityfor folding on site. Stainless steel Therefore for 120mm void = 120mmbrackets can be quoted and provided + 15mm + 10mm = 145mm of CW-CB/upon request. All holes are to be CW-FSsite drilled to suit the varying siteconditions.Dollar Bay, London12 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSMovement characteristics Design considerationsCurtain walling and external façade Important factors to consider for thedeflection application of fire stops within curtain wall façades:The qualification of proprietary firestop systems are typically limited • Review the position of firestopby the condition that they must be and distance from fixing bracketinstalled in a static environment. connection.However, for curtain walling • E nsure structural engineer specifiesapplications it is imperative that the façade defelction.the installed seal is able to functioneffectively with due regard to all • R eview the curtain wall expansiondesigned movement serviceability and any floor slab/building movement.limits. Siderise recognise that curtainwalling and cladding façade systems • Review transom/mullion deflection.will deflect due to: Upon confirmation and consideration• Positive wind-load of the above parameters, the required• Negative wind-load fire stop compression factor can• Occupational live load be assessed for the specific project application.The above are covered by EN 13116:2001 Note 1: Siderise CW vertical fireTypically, a project may stipulate that stop systems can accommodatethe curtain walling system may have the façade deflection due to their uniquefollowing allowable deflection limits: construction. However, material size is crucial to ensure that integrity isUnder the declared wind loads the maintained.maximum frontal deflection of thecurtain walling’s framing members shall Note 2: On a project basis, considernot exceed L/200 or 15mm, whichever both inward and outward deflectionis the less, when measured between requirements for the system.the points of support or anchorage tothe building’s structure in compliancewith EN 13116. [Extract from EN 13830]These factors may inevitably combineto preclude the suitability andtherefore, use of certain systems e.g.high density material slab products.However, the CW perimeter barriersand fire stop systems are very effectivein their function within curtain wallingas the unique material constructioncan accept the cyclical negative andpositive wind and live loads imposedon the façade.| 13VERSION 1.9 SEPTEMBER 2021The Scalpel, London14 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSHorizontal perimeter barrier installation: CW-FSH-01-A Curtain Wall Fire Stop Siderise CW-FS 75% Fixed Bracket Spandrel Panel Siderise Bracket Siderise NXR CoreFixed BracketSiderise Bracket 75% Spandrel Panel Siderise NXR CoreCurtain Wall Fire StopSiderise CW-FS Products used Siderise curtain wall fire stop CW-FS Siderise support brackets Siderise Nexus Core ‘NXR’Horizontal perimeter barrier installation: CW-FSH—02—A | 15VERSION 1.9 SEPTEMBER 2021 Curtain Wall Fire Stop Fixed Bracket Siderise CW-FS Siderise BracketFoil Tape Spandrel InsulationSiderise FT 120/45 Non Fire RatedFixed Bracket Spandrel InsulationSiderise Bracket Non Fire RatedCurtain Wall Fire StopSiderise CW-FS Products used Siderise curtain wall fire stop CW-FS Siderise support brackets Spandrel insulation (non fire rated)16 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS Fixed Bracket Siderise BracketHorizontal perimeter barrier installation: CW-FSH—03—A Curtain Wall Fire Stop Siderise CW-FSFoil Tape Composite PanelSiderise FT 120/45 Siderise NXS FusionFixed Bracket Composite PanelSiderise Bracket Siderise NXS FusionCurtain Wall Fire StopSiderise CW-FS Products used Siderise curtain wall fire stop CW-FS Siderise support brackets Siderise Nexus Fusion ‘NXS’Horizontal perimeter barrier installation: CW-FSH—04—A | 17VERSION 1.9 SEPTEMBER 2021 Curtain Wall Fire Stop Firestop Support Bracket Siderise CW-FS Siderise BracketFoil Tape Fire Rated BoardSiderise FT 120/45 Siderise CW-FB BoardFirestop Support Bracket Steel TraySiderise Bracket min 0.9mm 75% Fire Rated Board Siderise CW-FB BoardCurtain Wall Fire StopSiderise CW-FS Products used Siderise curtain wall fire stop CW-FS Siderise support brackets Siderise CW-FB Spandrel protection18 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS Fixed Bracket Siderise BracketHorizontal perimeter barrier installation: CW-FSH—03—B Curtain Wall Fire Stop Siderise CW-FSFoil Tape Composite PanelSiderise FT 120/45 Class ‘A1’ Thermal InsulationFixed Bracket (min 80kg/m3)Siderise Bracket Composite PanelCurtain Wall Fire Stop Class ‘A1’ Thermal InsulationSiderise CW-FS (min 80kg/m3) Products used Siderise curtain wall fire stop CW-FS Siderise support brackets Class ‘A1’ (min 80kg/m3) Thermal InsulationHorizontal perimeter barrier installation: CW-FSH—04—B | 19VERSION 1.9 SEPTEMBER 2021 Curtain Wall Fire Stop Firestop Support Bracket Siderise CW-FS Siderise BracketFoil Tape 75% Fire Rated BoardSiderise FT 120/45 Siderise CW-FB BoardFixed Bracket Steel TraySIDERISE Bracket min. 0.9mmCurtain Wall Fire Stop Fire Rated BoardSIDERISE CW-FS SIDERISE CW-FB Board Products used Siderise curtain wall fire stop CW-FS Siderise support brackets Siderise CW-FB Spandrel protection20 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSHorizontal perimeter barrier installation: CW-FSH—05—AAcoustic Overlay Fixing Strap Fixed BracketSiderise CW-AB Generic Fixing Strap Siderise BracketFoil Tape Spandrel PanelSiderise FT 120/45 Siderise NXR CoreFixed Bracket Acoustic OverlaySiderise Bracket Siderise CW-AB Spandrel PanelFixing StrapGeneric Fixing Strap Siderise NXR CoreCurtain Wall Fire StopSiderise CW-FS Products used Siderise curtain wall fire stop CW-FS Siderise support brackets Siderise Nexus lamella boards Siderise acoustic barrier overlay ABHorizontal perimeter barrier installation: CW-FSH—06—A | 21VERSION 1.9 SEPTEMBER 2021Acoustic Overlay Fixing Strap Fixed BracketSiderise CW-AB Generic Fixing Strap Siderise BracketFoil Tape Spandrel PanelSiderise FT 120/45 Siderise NXR CoreFixed Bracket Acoustic OverlaySiderise Bracket Siderise CW-AB Spandrel PanelFixing StrapGeneric Fixing Strap Siderise NXR CoreCurtain Wall Fire StopSiderise CW-FSAcoustic UpgradeSiderise CVB Products used Siderise curtain wall fire stop CW-FS Siderise support brackets Siderise nexus lamella boards Siderise acoustic barrier overlay AB Siderise acoustic upgrade CVB/C22 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSHorizontal perimeter barrier installation: CW-FSH—07—A Spandrel Panel Siderise NXR CoreCurtain Wall Firestop Foil TapeSiderise CW-FS Siderise RFT 120/45Curtain Wall Fire Stop Spandrel PanelSiderise CW-FS Siderise NXR CoreFixed BracketSiderise Bracket Products used Siderise curtain wall fire stop CW-FS| 23VERSION 1.9 SEPTEMBER 2021Vertical perimeter barrier installation: CW-FSV—08—A Fixed Bracket Siderise Bracket Fixed Bracket Siderise BracketFoil Tape Curtain Wall Fire Stop Spandrel PanelSiderise FT 120/45 Siderise CW-FS Siderise NXR CoreFixed Bracket Curtain Wall FirestopSiderise Bracket Siderise CW-FSFixed Bracket Spandrel PanelSiderise Bracket Siderise NXR CoreCurtain Wall Fire StopSiderise CW-FSFoil TapeSiderise FT 120/45 Products used Siderise nexus lamella boards Siderise curtain wall fire stop CW-FS Siderise foil tape: RFT 120/4524 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS Fixed Bracket Siderise BracketVertical perimeter barrier installation: CW-FS—08—B Curtain Wall Firestop Siderise CW-FSFoil Tape Curtain Wall Fire Stop Spandrel PanelSiderise FT 120/45 Siderise CW-FS Siderise NXR CoreFixed Bracket Curtain Wall Fire StopSiderise Bracket Siderise CW-FSCurtain Wall Fire Stop Spandrel PanelSiderise CW-FS Siderise NXR CoreCurtain Wall Fire StopSiderise CW-FSFoil TapeSiderise FT 120/45 Products used Siderise Nexus lamella boards Siderise curtain wall fire stop CW-FS Siderise foil tape: RFT 120/45| 25VERSION 1.9 SEPTEMBER 2021Vertical perimeter barrier installation: CW-FS—08—C Fixed Bracket Siderise Bracket Curtain Wall Fire Stop Siderise CW-FSMullion Insert Curtain Wall Fire Stop Spandrel PanelSiderise MI6 Siderise CW-FS Siderise NXR CoreFixed Bracket Mullion InsertSiderise Bracket Siderise MI6Curtain Wall Fire Stop Curtain Wall Fire StopSiderise CW-FS Siderise CW-FSCurtain Wall Fire Stop Spandrel PanelSiderise CW-FS Siderise NXR CoreFoil TapeSiderise FT 120/45 Products used Siderise Nexus lamella boards Siderise curtain wall fire stop CW-FS Siderise foil tape: RFT 120/4526 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPSRegulations guidance Siderise CW-CB Cavity Barriers have For the purpose of Siderise product been developed in recognition terminology, the ‘imperfection of fit’• Approved Document B of the of the more demanding requirements is considered to be the discontinuity Building Regulations requires that of the ‘Design Guide for the Fire between the edge of the structural cavity barriers must have a minimum Protection of Buildings’ as issued by frame (slab or wall) and the interface standard fire resistance of 30 The Loss Prevention Council. with the external cladding system. minutes integrity and 15 minutes insulation with regards to EN 1366-4 Cavity barriers … a definition “A Siderise CW-FS60 is suitable for criteria respectively (EI 15). construction provided to close a installation in alignment with a 1 hour concealed space against penetration rated compartment wall or floor to• The Loss Prevention Council’s of smoke or flame, or provided to provide continuity of fire resistance ‘Design Guide for the Fire Protection restrict the movement of smoke or across the cavity (EI 60). of Buildings’ states that cavity flame within such a space”. barriers must have 30 minutes Siderise CW-FS120 is suitable for integrity and minimum 30 minutes Siderise CW-CB30 is suitable for use installation in alignment with a 90 fire insulation (EI 30). as a cavity barrier (EI 30). minute or 2 hour rated compartment wall or floor (EI 120).• The ‘Standard Performance Criteria’ Siderise CW-FS Fire Stops are used for fire and smoke stopping to maintain the continuity of the fire Siderise CW-FS180 is suitable for issued by the Centre for Window resistance by sealing the gap between installation in alignment with a 3 hour and Cladding Technology states: compartment floors (and walls) and compartment floor (EI 180). “There shall be continuity of time the external curtain walling façade or temperature rated fire and smoke any other external cladding systems. stopping between the curtain wall and compartment walls and floors. Fire stops … a definition “Sealing an Any spaces or cavities between the imperfection of fit or design tolerance two shall be effectively stopped between fire rated elements of a against the spread of smoke and building to restrict the passage of fire flame. The fire resistance of such and smoke for the same period of fire stopping shall be equal to that resistance”. required of the compartment floor or wall against which it abuts”.Technical specificationSiderise Perimeter Barriers & Fire stops for Curtain WallingForm supplied Sheet : 1200mm x 1200mm x thickness (denoted by rating) Pre-cut strips : 1200mm x (cavity + compression as per Certifire/Intertek) x thickness –Colour please see tables 1 to 3Finish Silver, with coloured identification tape centrally located on the productDensity Aluminium foilThermal conductivity Nominal 75 kg/m3Cavities λ10 = 0.038 W/m.K (tested foil to foil)Reaction to fire 20mm to 600mm - please see tables 1 to 3Resistance to fire EN 13501-1 : Class ‘A1’ EN 13501-2 : EI 30 to EI 180 (minutes) - please see tables 1 to 3| 27VERSION 1.9 SEPTEMBER 2021FURTHER INFORMATIONProducts available Ordering Technical & Sales supportThe following Siderise products are When ordering please: Sales supportavailable. Sales Team • Indicate contract title and location of T: +44 (0) 1656 730833• Siderise CW perimeter barriers and project. E: [email protected] fire stops for curtain walling – sheet or pre-cut strip options • Specify product type required, e.g. Technical support sheet form. Technical Services Team• Siderise Aluminium Jointing Tape T: +44 (0) 1656 730833 must be used at all joints and • Specify fire rating or thickness E: [email protected] intersections: RFT120/45 (120mm required. wide x 45m rolls) Adhesive backed, Site Services support Supplied in boxes of 8 • Specify void height or schedule of sizes for each product type. Siderise offer a range of services• Siderise Fire & Acoustic Sealant to contractors and installers. These may be used for small gaps and • Confirm total linear metres required include toolbox product installation undulations: FS120/310ML/WH (310ml for each size. and site installation inspection and cartridge) Supplied in boxes of 25 reporting (subject to availability and • Specify bracket type and quantity by agreement).Additional information available required Site Services TeamThe following information is available • Specify foil tape quantity T: +44 (0) 1656 730833for download via the website: requirement: RFT 120/45. E: [email protected]• NBS Specification Clause • Order Siderise fire and acoustic gap System testing support sealant 310ml cartridge• Safety Data Sheet Siderise can provide assistance and Environmental advice for large scale system testing to• Cutting and Installation instructions BS EN, NFPA, ASTM and AS standards. Siderise perimeter barriers and• 3rd party approval - Certifire ‘CF 563’ fire stops for curtain walling are Testing Support Team environmentally friendly. T: +44 (0) 1656 730833• 3rd party approval - Intertek ‘WHI9- E: [email protected] 32944301’ • They contain no Volatile Organic Compounds (VOCs) and no very Context• 3rd party approval - Intertek ‘WH20- Volatile Organic Compounds 32944302’ (vVOCs). The information in this datasheet is believed to be accurate at the date of • Zero Ozone Depleting Potential publication. Siderise has a policy of continuous product improvement and • Zero Global Warming Potential reserves the right to alter or amend the specifications of products without • Recyclable prior notice. Siderise does not accept responsibility for the consequences of Specification support using the products described outside of the recommendations within this Siderise offer specifiers support from datasheet. Expert advice should be initial enquiry and technical consultation sought where there is any doubt about to project realisation. NBS draft the correct specification or installation specifications are provided for standard of Siderise products. products and applications and can be tailored to suit specific project performance requirements.VERSION 1.72 APRIL 2021 | 28Siderise Insulation Siderise Special ProductsPassive fire solutions for the building Engineered acoustic solutions for equipmentenvelope manufacture and construction Siderise (Special Products) LtdUnited Kingdom Lady Lane Industrial EstateSiderise Group, Forge Industrial Estate, T: +44 (0) 1473 827695Maesteg, UK, CF34 0AY INDONESIAT: +44 (0) 1656 730833 | F: +44 (0) 1656 812509 PT. Kencana Mirae Industri Kawasan Ruko Business Park, Kebon Jeruk Blok I No.9Middle East & India Jakarta Barat, DKI Jakarta 11620 T : (+62) 21 5890 8283 | E : [email protected]Al Shafar Investment Building, www.kencanamirae.comAl Quoz Industrial Area 1, Dubai, UAET: +971 (0) 4 580 4999 MEMBERAsia PacificSiderise (Asia Pacific) Pte. Ltd. 80 Robinson Road,#02-00 Singapore 068898T: +65-963 19310www.siderise.com

Click to View FlipBook Version

Từ khóa » Cw-cb30