1 SIMATIC NET Installation Instructions Stand / Dated 04/98 INSTALLATION INSTRUCTIONS for the CP 5412 (A2) This document contains information in English. SIEMENS AG 1998 Subject to change SIEMENS Aktiengesellschaft 1

2 English SIMATIC NET Installation Instructions Dated 04/98 INSTALLATION INSTRUCTIONS for the CP 5412 (A2) SIEMENS AG 1998 Subject to change Siemens Aktiengesellschaft 2

3 Warning Startup Prior to startup you must observe the notes in the relevant documentation. For ordering data of the documentation please refer to catalogs or contact your local SIEMENS representative. Do not start up until you have established that the machine on which you intend to run this component complies with the directive 89/392/EEC. Information for the Reader Text Conventions The following symbol is used in the text to draw attention to important points. This symbol highlights important features and dangers. Registered Trademarks SIMATIC NET and SINEC are registered trademarks of Siemens AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners. The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility or design, are reserved. We have checked the contents of this manual for agreement with the hardware described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcome. SIEMENS AG 1998 All rights reserved Technical data subject to change. Oder no..: Orders to Gerätewerk Karlsruhe Printed in the Federal Republic of Germany Siemens Aktiengesellschaft

4 Introduction Overview These installation instructions describe the installation of the following products: DP-5412 under Windows 95 DP-5412 under Windows NT 4.0 FMS-5412 under Windows 95 FMS-5412 under Windows NT 4.0 S under Windows 95 S under Windows NT 4.0 PG-5412 under Windows 95 PG-5412 under Windows NT 4.0 Contents 1 The Package Hardware and System Requirements Hardware Requirements System Requirements General Requirements for Operating the CP Software Requirements for COM PROFIBUS Key Diskette and License Installing the Software Preparations for Installation Notes on Installation Starting Installation Hardware Configuration under Windows 95 and NT Software Configuration: Setting the PG/PC Interface Definition of Terms Making the Assignments CP 5412A2 (PROFIBUS) Parameter Set CP 5412A2 (MPI) Parameter Set Installing the CP Configuring COM PROFIBUS for DP-5412 and FMS COML S7 for S Diagnostics Troubleshooting Under Windows Under Windows NT Where to Get Help Technical Specifications...50 Installationsanleitung CP 5412 (A2) - Deutsch 5 C79000-Z8974-C39-01

5 Installation Instructions for the CP 5412 (A2) Overview of the Basic Steps in Installation Under Windows 95 Step Description 1 Install the software (see Chapter 4). 2 Restart your computer. 3 Configure the hardware (see Chapter 5) Installing The resources are assigned automatically in the Device Manager (you can review the resources in the Device Manager) 4 Setting the PG/PC Interface (see Chapter 6) Assignment Module parameter set 5 Shut the computer down. 6 Install the card (see Chapter 7). 7 Function test with the diagnostic tool (see Chapter 9). Under Windows NT 4.0 Step Description 1 Install the software (see Chapter 4). 2 Restart your computer. 3 Configure the hardware (see Chapter 5) Installation The resources are assigned manually. 4 Setting the PG/PC Interface (see Chapter 6) Assignment Module parameter set 5 Shut the computer down. 6 Install the card (see Chapter 7). 7 Function test with the diagnostic tool (see Chapter 9). 6 Copyright by SIEMENS AG

6 Installation Instructions for the CP 5412 (A2) 1 The Package Software Package German/English The product packages DP-5412, Windows 95 or Windows NT 4.0, FMS-5412, Windows 95 or Windows NT 4.0, S7-5412, Windows 95 or Windows NT 4.0, PG-5412, Windows 95 or Windows NT 4.0 each include the following: 1 SIMATIC NET CD 1 red key diskette with the license for the relevant product. Installation Instructions for the CP 5412 (A2) Software Product Certificate Product Information Bulletin SIMATIC NET CD The program package is shipped along with other SIMATIC NET products on a CD-ROM. The red diskette (key diskette) contains the authorization information for the program package and is not read-only Copyright by SIEMENS AG 7

7 Installation Instructions for the CP 5412 (A2) 2 Hardware and System Requirements 2.1 Hardware Requirements Computer Hardware Requirements This product can be used on SIMATIC programming devices (PGs) and AT-compatible PCs. For further information, please read the Readme.txt file in the main menu of the CD-ROM. The CP 5412 (A2) is a card for IBM-AT-compatible PCs/PGs and requires a 16-bit wide ISA slot. When installing the module, make sure that you take the usual precautions to avoid damage caused by electrostatic discharge (ESD). Opening the PC/programming device and inserting/removing the module is permitted only when the power supply is disconnected. Before installing the module, please read the section in the manual for your PC/programming device titled Installing Modules or similar and follow the instructions there. 8 Copyright by SIEMENS AG

8 Installation Instructions for the CP 5412 (A2) 2.2 System Requirements General Requirements for Operating the CP Operating System You require Windows 95 or Windows NT version 4.0 as the operating system. Software You require one of the following software packages: DP-5412 under Windows 95 DP-5412 under Windows NT 4.0 FMS-5412 under Windows 95 FMS-5412 under Windows NT 4.0 S under Windows 95 S under Windows NT 4.0 PG-5412 under Windows 95 PG-5412 under Windows NT 4.0 CP 5412 (A2) You require a CP 5412 (A2) SIMATIC NET communications processor for operation. Before plugging in the CP 5412 (A2) module, please set the I/O range proposed by the installation program. If you are installing several modules, make sure that a different I/O range is set on each CP. Copyright by SIEMENS AG 9

9 Installation Instructions for the CP 5412 (A2) I/O Range Each CP 5412 (A2) occupies four contiguous addresses in the I/O address area starting at a selectable base address. The following base addresses (hex) are available: 240, 244, 248, 24C, 280, 284, 288, 28C, 300, 304, 308, 30C, 390, 394, 398, 39C The Plug-and-Play functions of Windows 95 will automatically select a free I/O range. You should therefore first install the software in order to obtain a free I/O range. You then set this range on the CP 5412 (A2) before installing it. Under Windows NT, please make sure that the I/O ranges you select are not used for any other purpose in your system. Interrupt Each CP 5412 (A2) requires one interrupt for operation. This can be set in the software and can be selected from among the following values: IRQ 5, IRQ 10, IRQ 11, IRQ 12, IRQ 15. The Plug-and-Play functions of Windows 95 automatically select one of the interrupts listed above. Under Windows NT, make sure that the interrupt you select is not used already by other components in your system. Several CPs on one computer can share one interrupt. The first CP (without the entry SubBoard ) occupies the interrupt on the computer. The following CPs (with the entry SubBoard ) share the interrupt of the first CP. Dual-Port RAM Address Area Each CP 5412 (A2) occupies a memory area of 16 Kbytes during operation. The range position is set in the configuration program. 10 Copyright by SIEMENS AG

10 Installation Instructions for the CP 5412 (A2) Under Windows 95 The Plug-and-Play functions of Windows 95 automatically select a suitable DPRAM memory area. On some computer models with a memory configuration greater than 16 Mbytes, access to the ISA bus is only possible in areas D0000-DFFFF or E0000-EFFFF. You may have to change settings in the BIOS of your computer. For more information, read the BIOS description of your computer. If you use a memory management program, for example EMM386, you must inform the management program of the memory area you are using. With EMM386, for example, you would either add the following line to the CONFIG.SYS file Device=C:\DOS\EMM386.EXE X=D000-DFFF or modify the line accordingly if it already exists. For further options, please refer to your operating system manual and the memory manager you are using. Under Windows NT Make sure that the memory area you select is not used by any other component in your system (display in Windows NT diagnostics). On some computer models with a memory configuration greater than 16 Mbytes, access to the ISA bus is only possible in areas D0000-DFFFF or E0000-EFFFF. You may have to change settings in the BIOS of your computer. For more information, read the BIOS description of your computer. Space Required on the Hard Disk During installation, the space required by the software package is displayed and the destination drive is checked to make sure there is sufficient space. Copyright by SIEMENS AG 11

11 Installation Instructions for the CP 5412 (A2) Software Requirements for COM PROFIBUS This chapter applies to DP and FMS-5412-products only. COM PROFIBUS; Software Requirements Note To use the COM PROFIBUS configuration program, you require the following: Necessary Resources Specification Operating system Windows 95 or Windows NT Memory Free space on hard disk at least 8 Mbytes at least 10 Mbytes Type of processor at least The COM PROFIBUS configuration program is shipped on the SIMATIC NET CD in German and English. The COM PROFIBUS configuration program is installed automatically along with the DP-5412 package or with the FMS-5412 package. For more detailed information, refer to the readme file in the main menu of the CD. 12 Copyright by SIEMENS AG

12 Installation Instructions for the CP 5412 (A2) 3 Key Diskette and License Key Diskette Each product is supplied with a red key diskette (authorization diskette). This contains a license that is required to operate the product. This diskette is not read-only (see the position of the slide). Do not change the position of the write-protection slide! The license on the key diskette cannot be copied using disk copy functions. Keep this diskette in a safe place. Installing the License During installation, this license is transferred to your hard disk (default setting in the check box during installation). It is not possible to operate the product without the license. Please do not interrupt the transfer since the license could otherwise be lost. The key diskette cannot be copied. Location on Hard Disk The license is saved in the hidden directory \ax nf zz on the drive on which you installed the product. Please do not delete the directory \ax nf zz or any files it contains. The license cannot be transferred to a compressed drive. If your drive is compressed, select an uncompressed drive when installing the license. Copyright by SIEMENS AG 13

13 Installation Instructions for the CP 5412 (A2) AUTHORSW.EXE You can also install the authorization later using the AUTHORSW.EXE program on the key diskette. Start the AUTHORSW.EXE program:. Select the license you require in drive A:\. Using the menu Authorization > Transfer, select the destination drive for the authorization. If you want to reformat your hard disk, you must first transfer the license back to the key diskette using the AUTHORSW.EXE program on the key diskette. If you do not do this, the license is lost and you can no longer use the product. If you uninstall the license, make sure that you use the diskette from which you installed the it. The authorization information cannot be transferred from the hard disk to a diskette or from a diskette to the hard disk by simply using normal copy functions. 14 Copyright by SIEMENS AG

14 Uninstallers and the Authorization Installation Instructions for the CP 5412 (A2) If you uninstall this product with an uninstaller, you may lose the authorization. Explanation: This warning applies to all users that installed the product with an uninstaller. Note If you want to uninstall the product using an uninstaller, you must first transfer your license back to the key diskette using the AUTHORSW.EXE program on the key diskette. If you do not, then depending on the uninstaller, the license for this product may be destroyed. If a license cannot be detected, a message is displayed on the screen at regular intervals. Copyright by SIEMENS AG 15

15 Installation Instructions for the CP 5412 (A2) 4 Installing the Software 4.1 Preparations for Installation Preparations for Software Installation To prepare for software installation, follow the steps below: Read the README.TXT file on the CD-ROM. Read these installation instructions thoroughly. Installation from CD Installation from Diskette Under Windows 95 and Windows NT, you install the product using the SETUP.EXE installation program in the main directory on the CD. If you want to install the product on a computer without a CD-ROM drive, you must copy the required product from the CD to diskettes. How to do this is explained in the readme file on the CD. 16 Copyright by SIEMENS AG

16 Installation Instructions for the CP 5412 (A2) 4.2 Notes on Installation Screen Savers When using a screen saver, remember that it also requires CPU time and can lead to overload of the system. Some screen savers do not release all the memory they use and this can lead to a continuous reduction of available memory. Virus Scanners Using virus scanners during normal operation can cause problems in hardware extensions. It is advisable to run virus tests only when CP-5412/Windows NT is not running. Following a virus test, the computer should be reset before any process link is activated. Important! Before you install this product, please make sure that no other application has been started that uses existing SIMATIC NET components. Installation on the Same Drive Entries in the Registry (under Windows NT) If software components that would normally be replaced during installation of this product are already in use, they are retained and not replaced without any error message being displayed. This means that the installation is incomplete and you may encounter problems later during operation. If you have already installed a SINEC or SIMATIC NET product, you should always install the new product on the same drive! Please note that to install this product successfully, you must log on as an administrator with Windows NT. Otherwise important entries in the Windows NT registry cannot be made. If you are not authorized to write to the registry, the installation will be incomplete. Copyright by SIEMENS AG 17

17 Installation Instructions for the CP 5412 (A2) 4.3 Starting Installation Starting the Software Installation The software can only be installed with the supplied installation program since part of the software is compressed on the CD. To install the software, follow the steps below: Under Windows 95 Start Windows 95 Insert the SIMATIC NET CD in the CD-ROM drive. Start the SETUP.EXE file on your CD. Follow the instructions of the installation program. Select the check boxes of the products you want to install in the Components dialog. Under Windows NT Start Windows NT Log on as administrator in your Windows NT system. Insert the SIMATIC NET CD in the CD-ROM drive. Start the SETUP.EXE file on your CD. Follow the instructions of the installation program. Select the check boxes of the products you want to install in the Components dialog. 18 Copyright by SIEMENS AG

18 Installation Instructions for the CP 5412 (A2) Read the readme.txt file of the product. You can open the file by clicking the product you want to install and then clicking the Readme button. If you have decided to install the authorization, you will be asked to insert the key diskette in the floppy drive. Continue the installation until it is completed. Then reboot your computer. Read the readme.txt file of the product. You can open the file by clicking the product you want to install and then clicking the Readme button. If you have decided to install the authorization, you will be asked to insert the key diskette in the floppy drive. Continue the installation until it is completed. Then reboot your computer. Where to Go from Here After you have installed the software, you configure the module by installing a CP and assigning resources to it. You then configure the software by creating the access point for the application and assigning a module parameter set to the access point (see Chapter 6). Note The COM PROFIBUS configuration program is automatically installed with the DP-5412 or FMS-5412 package. Copyright by SIEMENS AG 19

19 Installation Instructions for the CP 5412 (A2) 5 Hardware Configuration under Windows 95 and NT 4.0 Setting the PG/PC Interface With the Setting the PG/PC Interface configuration program, you can install the hardware and assign parameters to PROFIBUS communication connections. Preparations for Configuring Modules After you have installed the software on your hard disk, start the configuration program to configure the CP 5412 (if it was not started automatically). If you have already installed a CP 5412 (A2) in your computer under Windows 95 or Windows NT 4.0 and only want to operate an additional software package, you can skip this section and move on to configuration of the software. 20 Copyright by SIEMENS AG

20 Installation Instructions for the CP 5412 (A2) Specifying the CP and the Identifier SubBoard The hardware list box displays CPs, some of which include the entry SubBoard. This entry relates to interrupts. Several CPs on one computer can share one interrupt. The first CP (without the entry SubBoard ) occupies the interrupt on the computer. The following CPs (with the entry SubBoard ) share the interrupt of the first CP. Copyright by SIEMENS AG 21

21 Installation Instructions for the CP 5412 (A2) Configuring Modules To configure the hardware, follow the steps below: Step Description 1 Turn on your computer and start Windows 95 or Windows NT Start the configuration program Setting the PG/PC Interface : With the Setup program if you selected the option Yes, start configuration program now in the last dialog of the Setup program. or Via the Simatic path (taskbar Start -> SIMATIC -> SIMATIC NET -> Setting the PG/PC Interface). or Using the Control Panel of Windows 95 (taskbar -> Settings -> Control Panel -> Setting the PG/PC Interface). 3 Click the Install... button 4 In the Selection list box, select CP 5412 (A2). If you have installed more than one CP, select the first CP without the label SubBoard and the other CPs with the label SubBoard. Please note, that one CP must always be installed that is not a SubBoard because the subboard CPs share the interrupt assigned to the CP that is not labeled SubBoard. 22 Copyright by SIEMENS AG

22 Installation Instructions for the CP 5412 (A2) 5 Click the Install -- > button to install the device. Copyright by SIEMENS AG 23

23 Installation Instructions for the CP 5412 (A2) 6 Under Windows NT 4.0 only: In the Resources dialog, you will find a pair of values, for example 0240H-0243H under the entry Input/Output Range. Note down the value. You require this later to set the I/O range on the CP 5412 (A2). Under Windows 95 only: The parameters Interrupt and Memory Range are selected automatically by the Plug and Play functions of the operating system and should only be modified manually by the user in exceptional situations in the system configuration (Control Panel ->Device Manager). Under Windows 95, the resources assigned to the CP by the system are displayed in the Device Manager. 24 Copyright by SIEMENS AG

24 Installation Instructions for the CP 5412 (A2) The Resources tab displays a pair of values, for example 0240H-0243H, for the Input/Output Range. Note down the value. You require this later to set the I/O range on the CP 5412 (A2). The figure above shows a typical display when no conflicts have been detected. If conflicts are indicated, the resources must be reassigned manually in the Device Manager. Copyright by SIEMENS AG 25

25 Installation Instructions for the CP 5412 (A2) 6 Software Configuration: Setting the PG/PC Interface Configuring the Software After you have selected the hardware parameters, you can configure the software for the CP 5412 (A2). Setting the PG/PC Interface With the Setting the PG/PC Interface configuration program, you can install the hardware and assign parameters to PROFIBUS communication connections. 26 Copyright by SIEMENS AG

26 Installation Instructions for the CP 5412 (A2) 6.1 Definition of Terms Setting the PG/PC Interface With the Setting the PG/PC Interface configuration program, you can assign parameters to PROFIBUS communication connections. Access Point of Application The access point of the application is the name of a communication connection. Applications and libraries can access the module using the application point. Module Parameter Sets Module parameter sets contain all the Properties of a network access point. This includes the underlying hardware, the station parameters and the bus parameters. Copyright by SIEMENS AG 27

27 Installation Instructions for the CP 5412 (A2) 6.2 Making the Assignments After hardware configuration, you automatically return to the Access Path tab in which you can configure the software. In this case, start at step 2 in the table below. Procedure for Software Configuration Step Description 1 Start the Setting the PG/PC Interface configuration program via the Start menu of the taskbar (Start>Simatic>SIMATIC NET > Setting the PG/PC Interface) or via the Control Panel (Start>Settings>Control Panel >Setting the PG/PC Interface) 2 Select an access point in the Access Point of Application list box, for example by clicking it with the mouse. Reaction: The assigned module parameter set is displayed in the list box. If you have not yet made an assignment, the entry None is activated. If you select <Add/Delete>, you can also create a new access point in the list box. 28 Copyright by SIEMENS AG

28 Installation Instructions for the CP 5412 (A2) If you are working with DP-5412 or with STEP 5: Use the defined access points CP_L2_X: where X = 1 to 4. The number X must be specified as the CP number in the reference.board structure element when you call dpn_init(). If you are working with FDL: You can use any access points. These must be entered as a parameter for the SCP_OPEN() call. If you are working with SAPI S7: You can select your own name for the access point. The access point must be specified in the program as the parameter cp_name of the s7_init command. If you are working with SAPI FMS: You can select your own name for the access point. If you are working with STEP 7: You must use, for example, the access point S7ONLINE to communicate with S7 programmable controllers. You can also use this name in your program. 3 Create the assignment of access point to module parameter set, for example by clicking the required module parameter set with the mouse in the Assigned Module Parameter Set list box. For the PROFIBUS module parameter set see Section For the MPI module parameter set see Section Configure the selected module parameter set using the Properties button. This opens a dialog in which you can assign parameters for the interface. 5 Repeat steps 2 and 3 for further access points. 6 Close the configuration program with OK to save your assignment, with Cancel to save no new assignments. 7 Shut down your computer and turn it off. Install the CP 5412 as described in Chapter 7. Copyright by SIEMENS AG 29

29 Installation Instructions for the CP 5412 (A2) If you do not assign an access point to a module, it is not possible to operate the module. The configuration program proposes the default device name as CP_L2_x: where x is the number of the CP = 1, 2,... If you use the DP programming interface, this default must not be modified since the DP libraries use this name as standard. In other words, CP_L2_x must be assigned to the CP5412A2(PROFIBUS). For more detailed information about configuration, refer to the help function of the called configuration program. Starting the Driver When you reboot your system, the protocols you have activated are started automatically. Note Check all the settings of your PG/PC interface. In particular, check the access point and the module parameter set, before continuing with the configuration. Properties of the Standard Parameter Sets The standard parameter sets for a module differ in terms of the underlying network type and consequently in the parameter assignment options they provide. Setting DP Bus Parameters The bus parameters for DP or for FMS is cannot be set using the Setting the PG/PC Interface configuration program. They are set during configuration with COM PROFIBUS and entered in the database. 30 Copyright by SIEMENS AG

30 Installation Instructions for the CP 5412 (A2) CP 5412A2 (PROFIBUS) Parameter Set CP 5412A2 (PROFIBUS) Parameter Set Using the standard parameter set CP 5412A2 (PROFIBUS) allows access to PROFIBUS networks for SAPI-S7, SAPI-FMS, DP applications or FDL applications and applications based on other protocols (for example STEP 7). In the Properties dialog, you can modify the PROFIBUS parameters. Under Station Parameters, the local parameters can be set: the local station number and a layer 4 timeout (irrelevant for the user). With the Not the only master active check box, you can decide how the module is included in the PROFIBUS ring. If this option is activated, the module can enter the active ring when the module is already turned on. If the module is to be the only master in the PROFIBUS network, this option must be deactivated. The network parameters apply to the entire PROFIBUS network and must match on all nodes. Copyright by SIEMENS AG 31

31 Installation Instructions for the CP 5412 (A2) PROFIBUS Network Properties Tab The bus profiles contain predefined data records with bus parameters. Select the DP bus profile if you operate only S7 components on your PROFIBUS network. If you also have S5 components or third party components on the bus, you must select the Universal profile. Select the Standard bus profile for multi-master operation with fast bus nodes. If you set the User-defined bus profile, you can set the bus parameters after clicking the Bus Parameters... button. If you set one of the other bus profiles, you can only view the bus parameters. The following dialog appears after clicking Bus Parameters : 32 Copyright by SIEMENS AG

32 Installation Instructions for the CP 5412 (A2) FMS/DP Protocol Tab The communication connections via the FMS or DP communication protocol are specified in a database created with the COM PROFIBUS configuration tool (see Chapter 8). The database is specified in a module parameter set in the FMS/DP Protocol Properties page. Specify the name with the extension (ldb) and path of the DP or FMS database. You can search for the database using the Search button. A DP or FMS database must be specified to allow communication via the DP or FMS protocol! Copyright by SIEMENS AG 33

33 Installation Instructions for the CP 5412 (A2) S7 Protocol Tab Communication connections using the S7 communication protocol are specified with the COML S7 configuration tool (see Chapter 8). The database is selected in a module parameter set in the SAPI S7 Properties page. Specify the name with the extension (ldb) and path of the S7 database. You can search for the database using the Search button. An S7 database must be specified to allow communication via the S7 protocol! 34 Copyright by SIEMENS AG

34 Installation Instructions for the CP 5412 (A2) Mode Dialog In the Mode dialog, you can check the operating mode of your CP. If, for example, you select a new database in the Properties, you do not need to reboot your computer but must restart the CP In the dialog shown here, the CP was reset, restarted and then tested. To test the mode of the CP 5412, the CP 5412 must be installed permanently in the computer. Copyright by SIEMENS AG 35

35 Installation Instructions for the CP 5412 (A2) CP 5412A2 (MPI) Parameter Set CP 5412A2 (MPI) Parameter Set The standard parameter set CP 5412A2 (MPI) allows access to MPI networks and to SAPI-S7. The network parameters are valid for the entire MPI network and must match on all nodes. The transmission rate in MPI networks can only be set to 187 Kbps and 1.5 Mbps. It is not possible to set the bus parameters. In the Properties dialog, you can modify the MPI bus parameters. Under Station Parameters, the local parameters can be set: the local station number and a layer 4 timeout (irrelevant for the user). With the Not the only master active check box, you can decide how the module is included in the PROFIBUS ring. If this option is activated, the module can enter the active ring when the module is already turned on (default for MPI networks). MPI Network Properties Dialog 36 Copyright by SIEMENS AG

36 Installation Instructions for the CP 5412 (A2) S7 Protocol Properties Page The communication connections using the S7 communication protocol are specified in a database created with the COML S7 configuration tool (see Chapter 8). The database is specified in a module parameter set in the SAPI S7 tab of the Properties dialog. Specify the name with the extension (ldb) and path of the S7 database. You can search for the database using the Search button. An S7 database must be specified to allow communication via the S7 protocol! Copyright by SIEMENS AG 37

37 Installation Instructions for the CP 5412 (A2) Mode Dialog In the Mode dialog, you can check the operating mode of your CP. If, for example, you select a new database in the Properties, you do not need to reboot your computer but must restart the CP In the dialog shown here, the CP was reset, restarted and then tested. To test the mode of the CP 5412, the CP 5412 must be installed permanently in the computer. 38 Copyright by SIEMENS AG

38 Installation Instructions for the CP 5412 (A2) 7 Installing the CP 5412 DIL Switch To install the CP 5412 (A2), you require the values assigned for the input/output range of the CP 5412 (A2) during hardware configuration. Configuration Register Setting the DIL switch All the values required to operate the module are downloaded to the CP by the software from the configuration register. The configuration register occupies four addresses in the input/output range of the PC. The four addresses that are used are set using a DIL switch. The figure below shows the DIL switch on the CP 5412 (A2) module. The default setting of the DIL switch is DIL switch Switch up = "1" Switch down = "0" Selecting the I/O Range The following table shows the various combinations of switch settings and the I/O range they select: Copyright by SIEMENS AG 39

39 Installation Instructions for the CP 5412 (A2) Switch Setting I/O Range (hex.) (standard) B C-24F B C-28F B C-30F B C-39F The selected I/O range must not be used by any other card. Starting the Driver When you reboot your system, the protocols you have activated are started automatically. 40 Copyright by SIEMENS AG

40 Installation Instructions for the CP 5412 (A2) 8 Configuring Note No further configuration is necessary for FDL COM PROFIBUS for DP-5412 and FMS-5412 Note If COM PROFIBUS does not start on a Windows NT System, check whether the correct path is entered in the environment variable PATH. Remember that the AUTOEXEC.BAT file can be empty or may not exist in a Windows NT system. In this case, you must make the required entries in the PATH environment variable yourself. Note COM PROFIBUS was installed along with DP-5412 or FMS Function of COM PROFIBUS You require the COM PROFIBUS V3.3 configuration software to configure the bus structure, the DP master and the DP slaves. You can also create comprehensive system documentation with COM PROFIBUS. Procedure Follow the steps below to create a binary database for DP or for FMS with the COM PROFIBUS program: Step Description 1 Start the COM PROFIBUS program from the Start menu (Start>Programs>Siemens COM PROFIBUS>COM PROFIBUS). 2 Start a new configuration with the menu command File > New. 3 For the DP protocol: Select the station type CP5412 (A2) as DP master in the Master-Host Selection dialog in COM PROFIBUS and specify the station address of the master. Confirm with OK. For the FMS protocol: Select the station type CP5412 (A2) as FMS master in the Master-Host Selection dialog in COM PROFIBUS and specify the station address of the master. Confirm with OK. Reaction: A new project with the specified master is created. Copyright by SIEMENS AG 41

41 Installation Instructions for the CP 5412 (A2) 4 Configure the DP or FMS network with COM PROFIBUS, as described in the manual ET 200 Distributed I/O System Chapters 7 and 8 or in the online help of COM PROFIBUS. (Enter the bus parameters with the menu command Configure > Bus Parameters, select the slaves and enter the slave parameters (Configure > Slave Parameters ) ). 5 Save the configuration (menu command File > Save ). The project file has the extension.et2. 6 Create the DP or FMS database (.LDB and.txt) in the NCM format (extension.ldb using the menu command File > Export > NCM File. Reaction: The converter is started. It creates a loadable database (.LDB), an ASCII database (.TXT) and an ASCII output file (.ERR). 7 Enter the name of the DP database in the configuration program Setting the PG/PC Interface : Start the configuration program (for example taskbar Start > Control Panel > Setting the PG/PC Interface ). Now select an interface name CP_L2_X: (X=1..4) that references a module parameter set 5x11 (DP master) or create the assignment. 8 Click the Properties. button Reaction: The PROFIBUS FMS/DP Master Properties page appears. 9 Now enter the path and the file name of the previously created database (.LDB). Use the Search... button to browse through your hard disk(s). Confirm your entries with OK. 10 Check the setting of the check box Not the only active master. This option should only be activated if you want to connect the CP to an active PROFIBUS. If the CP of the PG / PC is the only master, the option must be deactivated! Confirm all the settings with OK. 11 You can now start your DP or FMS master application. To test your application, you can use the sample program DPMDEMO.EXE or FMSDEMO.EXE. These can be started in the program menu. 42 Copyright by SIEMENS AG

42 Installation Instructions for the CP 5412 (A2) 8.2 COML S7 for S Function of COML S7 The COML S7 configuration tool installed along with S is used to specify the basic information required by the S7 programming interface (SAPI-S7) to establish connections. Procedure Follow the steps below to create a database for S7: Step Description 1 Start the COML S7 program from the Start menu (Start>Programs>SIMATIC NET>DP-5412>COML S7). 2 Start a new configuration with the menu command File > New. 3 Select PROFIBUS as the network type. 4 Configure the S7 connections as described in the manual Configuring the S7 Mode with COML S7. The manual is on the SIMATIC NET CD. Refer also to the online help for COML S7. 5 Save the configuration (menu command File > Save Text DB). 6 Create the S7-database (.LDB) using the menu command File > Create Binary DB As... Close the COML S7 program. 7 Specify the name of the S7 database in the Setting the PG/PC Interface configuration program: Start the configuration program (for example taskbar Start > Control Panel > Setting the PG/PC Interface). Now select an interface name (for example CP_L2_1:) that refers to a module parameter set or create the assignment. 8 Click the Properties button. Reaction: The PROFIBUS Network or MPI Network Properties page appears. 9 Select the SAPI-S7 tab. Now enter the path and the file name of the previously created database (.LDB). Click the Search... button to browse through your hard disk(s). Confirm your entries with OK. 10 Check the setting of the check box Not the only active master. This option should only be activated if you want to connect the CP to an active PROFIBUS. If the CP of the PG / PC is the only master, the option must be deactivated! Confirm all the settings with OK. 11 You can now start your S7 application. To test your application, examples are available as source code. Copyright by SIEMENS AG 43

43 Installation Instructions for the CP 5412 (A2) 9 Diagnostics Diagnostics In the Setting the PG/PC Interface dialog, click the Diagnostics button to check the installation of the module. 44 Copyright by SIEMENS AG

44 Installation Instructions for the CP 5412 (A2) PROFIBUS Network Diagnostics In the PROFIBUS/MPI Network Diagnostics tab page, you can test your PROFIBUS network: Click the Test button. This displays the bus parameters, the local address and the state of the nodes on the network. Click Read to display the life list. Normally this is confirmed with O.K. in the dialog box beside it. If an error occurs, you will receive a detailed error message Example here: Active station (the CP 5412) with address 0 alone on the bus. Copyright by SIEMENS AG 45

45 Installation Instructions for the CP 5412 (A2) S7 Protocol Diagnostics Using the dialog in the figures shown below, you can test your configurations. 46 Copyright by SIEMENS AG

46 Installation Instructions for the CP 5412 (A2) DP RAM Dialog In the DP-RAM dialog, you can obtain information about the DP-RAM by clicking Read. Copyright by SIEMENS AG 47

47 Installation Instructions for the CP 5412 (A2) 10 Troubleshooting 10.1 Under Windows 95 Resource Problem? In the Control Panel, you can reassign resources (by double-clicking the entry CP 5412 (A2) ). Check whether there is a resource conflict in the Device Manager. Wrong PG/PC Setting? Check whether the access point and the module parameter set match. Configuration Problem? Check that the LDB database exists and that it is entered in the PG/PC interface. Check the station addresses and the selected bus parameters Under Windows NT 4.0 Initialization not Working? The standard settings cannot be used. The I/O address, the interrupt or the DPRAM address range must be modified. Check the resources used in your system before modifying settings. PC Does not Boot Correctly? While Windows NT is starting, press the space bar to start up with the last functioning configuration. Then assign free resources to the CP5412(A2). Checking Used Address Ranges To find out which I/O addresses, interrupts and DPRAM address range are already being used,start the Windows NT Diagnostics program in the Management group. With the IRQ/Port Status button, you can obtain information about interrupts and I/O ranges that are already being used, with the DMA/Memory button you obtain information about physically occupied address ranges. Setting PC Hardware- Parameters For information about setting the PC hardware parameters (interrupts, I/O port, DP-RAM range), please refer to the notes on configuring the CP5412(A2). On some computer models with a memory configuration greater than 16 Mbytes, access to the ISA bus is only possible in areas D0000-DFFFF or E0000-EFFFF. You may have to change settings in the BIOS of your computer. For more information, read the BIOS description of your computer. Configuration and Application Problems Reboot your computer and make sure that your logged on as a user with administrator rights. 48 Copyright by SIEMENS AG

48 Installation Instructions for the CP 5412 (A2) 11 Where to Get Help Documentation Information about using this product can be found in the following sources: in the corresponding paper documentation (refer to the \DOC directory on the CD) in the online help (F1 key) in the relevant text and PDF files on the SIMATIC NET CD in the Start file in the \DOC directory on the SIMATIC NET CD from March Who to Contact If you have technical questions about using the software and your problem is not dealt with in the documentation or in the integrated help system, please contact your Siemens representative or dealer. The addresses are listed in the following: in our catalog IK 10 on the Internet ( Common Questions Our customer support on the Internet provides useful information and answers to common questions. Under FAQ (Frequently Asked Questions), you will find information about the entire range of products: (Support, Training and Service). Hotline Note If you have problems, you can also contact our hotline: Telephone: (outside Germany ) Telefax: (outside Germany ) [email protected] Mailbox (BBS, analog/isdn, 8N1): (outside Germany ) If you phone our hotline, please try to have the following information available: Manufacturer and type of computer. You operating system version. BIOS version. Software version. Version of the CP. Your configuration Copyright by SIEMENS AG 49

49 Installation Instructions for the CP 5412 (A2) 12 Technical Specifications Circuit design Microprocessor Communication ASIC NEC PD (V53A) ASPC2 Memory Dynamic RAM Dual-port RAM 1 Mbyte 64 Kbytes (only 16 Kbytes window) Connector PC connection SINEC PROFIBUS attachment ISA/AT connector 9-pin sub D female connector Power supply +5 V, +-5 % Current consumption (approximate) 0.8 A (at +5 V) Type of protection IP 00 complying with DIN Permitted ambient temperature Operating temperature Storage temperature 0 C to +55 C -20 C to +70 C Humidity class to DIN F (max. 95 % at 25 C) Maximum Altitude During operation During transportation 3000 m above sea level 5000 m above sea level Construction Format Dimensions (H x D) in mm Installation width Weight approx. Printed circuit board Short ISA/AT format 107 x standard slot ( = mm) 0.2 kg Transmission rate 9.6 to Kbps, in steps 50 Copyright by SIEMENS AG