SR Mini HG SYSTEM(H-PCP-J) | RKC Instrument Inc.
- Digital Controllers
- RZ series
- RB series
- SA100
- SA200
- CB Series
- CB103 / CB403 / CB903
- REX-Century series
- FZ series
- FB series
- GZ series
- REX-F9000
- SB1
- Module Type Controllers
- SRZ
- SR Mini HG SYSTEM
- SR Mini HG SYSTEM(PLC communication:H-PCP-J)
- SRX series
- Communication Converters
- COM-ME series
- COM-MC
- COM-ML series
- COM-KG
- COM-A
- Multiloop Controllers
- MA900 / MA901
- Ramp / Soak Controllers
- PZ400 / PZ900
- PF900
- FM Approved Limit Controllers
- SA100L
- SA200L
- CB100L
- Indicators
- AG500
- AE500
- Hand Held Temperature Indicators
- DP-350
- Handheld temperature sensors (for stationary surface)
- Handheld Temperature Sensors (For fluids and inside of semi-solid objects)
- Recorders
- VGR-B100
- SBR-EW100 / EW180
- Software
- PROTEM3
- Zeal2
- VGR-B100 TOOL
- Temperature Sensors
- General Purpose Temperature Sensors
- Temperature sensors for various applications
- ST-50 series
- ST-55 / ST-56
- FT-100(Thermocouple K) FR-100(Resistance Temperature Detector)
- STM-A
- Resin Pressure Sensors
- CZ-100P
- CZ-200P
- PCT-300
- PG500
- Level Sensors
- LE100 / LE110
- LT1
- Radiation Thermometers
- BTM-30 / BTM-40
- BTM-80
- LTM-100
- Power Controllers
- THV-10(20A to 100A)
- THV-10(150A, 200A)
- High-speed type THV-10 [Z-1314](20A to 100A)
- THV-A1
- SSNP / SSNZ
- THV-40 (for high voltage load)
- THW-A
- Solid State Relay
- SSL
- SSJ
- SST
- Heater Break Alarms
- HBA-22
- HBA-T120 / HBA-T130
Related Information
Module Type Controllers Modular Controller (Process/Temperature Controller)SR Mini HG SYSTEM(PLC communication:H-PCP-J)
- Supplied with MAPMAN function which enables programmingless connection to a PLC.
- Measurement accuracy: ±0.3% of span (standard model), ±0.1% of span (accurate model)
- Sampling time: 0.5 sec. (standard model), 0.1 sec (accurate model)
- A wide selection of modules such as digital input/output, analog input/output, CT inputs, and temperature inputs.
- Temperature
- Process
- Multiloop Download
- Manuals
- Software
- Main features
- Main specification
- External dimensions
- Models
- Basic function Data management function: Operation data, System data Unit diagnosis function: Configuration check of function modules
- Digital output Number of outputs: 8 points Output type: Temperature alarms 1 and 2 (ALM1, 2), Heater break alarm, Burnout alarm Analog inputs 1 and 2 alarm (AI), Temperature inputs 1 and 2 (TI) alarm, Loop break alarm, Temperature rise completion, FAIL. (configurable) Output method: Open collector output (sink type)
- Communication Interface: RS-422A / RS-485 / RS-232C Protocol: 1) ANSI X3.28 (1976)2.5 B1 2) MODBUS 3) PLC commands (MAPMAN) ※ PLC commands are supported only on COM.port 1 and 2. Protocol is configurable among 1), 2) and 3).
- Power supply voltage (Rating): 100 to 120Vac / 200 to 240Vac/ 24Vdc
- Allowable ambient temperature: 0 to 50°C
- Weight: approx.300g
- Safety standard:
- Number of output: 16 points
- Output method: Open collector output (sink type)
- Functions: Master ch: Control output from (TIO module) Output limit function Output ratio function Control output cycle time: 1 to 100 sec.
- Input Number of input: 1 point Input type: 1) Voltage pulse input: High level voltage: 7 to 15Vdc, Low level voltage: 0 to 2Vdc 2) Open collector output Sensor power supply: 12Vdc ±10%, 70mA or less
- Control method: 1) Open loop control 2) Closed loop control (Brilliant PID control with Autotuning) ※PI control available
- Control computation cycle: 0.1 sec.
- Control output: 1) DC voltage output: 0 to 1V, 0 to 5V, 0 to 10V,1 to 5V dc 2) DC current output: 0 to 20mA, 4 to 20mA dc
- Alarm function (2 points): Process alarm, Deviation alarm, SV alarm
- Alarm output (1 point): Relay contact output, 1a contact
- External contact input (2 points) : Control ON/OFF, RUN/STOP
- Allowable ambient temperature: 0 to 50°C
- Weight: approx.120g
- Safety standards:
Main features
Programmingless connection to PLCs from various manufacturers

Programmingless connection to PLCs from various manufacturers is available.
※Available when H-PCP-J is connected.
※ Supported PLCs:
Mitsubishi Electric MELSEC series Omron SYSMAC series
Sharp JW series
Communication port to which a display unit can be connected can also be used simultaneously.
Output ratio function is available (on digital output module H-DO-G-D)

Manipulated output value of the master channel (H-TIO-[]) is multiplied by the output ratio (rate) of the slave channel (H-DO-G) and is provided as a distribution manipulated output.
Control of motor speed (Speed control module H-SIO-A)

This module receives pulse input from a rotary encoder for driving motor speed
Main specification
Refer to “SR Mini HG SYSTEM” for the configuration.
H-PCP-J module
<General Specification>
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE Marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive EN61326-1 RCM EN55011
H-DO-G Module
H-SIO-A module
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE Marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive EN61326-1
External dimensions
H-PCP-J

H-DO-G

H-SIO-A

Models
H-PCP-J

Important Notices
Please be careful of counterfeit products.
Từ khóa » Hg Hc
-
Semi-hermetic Refrigeration Compressor - HG HC Series
-
Semi-hermetic Refrigeration Compressor - HG HC Series - GEA Bock
-
The H-Hg (Hydrogen-Mercury) System - SpringerLink
-
What Does HGHC Stand For?
-
HGHC Definition - Law Insider
-
Recently Tried This Bowl Of Hakka Abacus Seeds 算盘子 ... - Instagram
-
Houston Global Health Collaborative: HGHC
-
HC Service Apartment By HG Hospitality - Hanoi Hotels
-
HTW-CC / HTW-HC-HG Series - Heavy Load Ball Type-Dongguan ...
-
The η1-H–C⋯Hg Agostic Interactions In The Mercury Complexes Of N ...
-
6-39 Determine The Force In Members BC, HC And HG. - YouTube