T8 G13 LED Tube 60cm 10W 4500K Frosted 92Lm/W

  • EN DE EN
  • Home
  • Contact us
  • request quotation
  • special offers
  • My account
  • Support +49-221-29821660 ----- E-Mail: team@cologne-led.de
  1. LED tubes
  2. Homepage
  3. LED tubes
  4. T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W
T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W
  • SKU: YM_T8_60_10W
  • Category: LED tubes
We offer a 10 Watt T8 LED tube, suited as energy efficient fluorescent tube replacement to be used in professional and industrial environments. The LED tube comes with a luminous flux of 951 lumen and 92 lm/watt light output in a frosted embodiment. This 60cm version is built with 4500k color temperature (neutral white) in OEM quality. Abdeckung  clear Frosted colour temperature  3000K (warm white) 4500K (neutral white) 6000K (daylight white) x This item has variations. Please select the requested variation. 24,40 € excl. 19% VAT , plus shipping costs (Standard-Paket) Please note our minimum order value of EUR 30.
  • Available immediately Availability: within 2-3 days
x This item has variations. Please select the requested variation.

fluorescent tube replacement to be used in professional and industrial environments. The LED tube comes with a luminous flux of 951 lumen and 92 lm/watt light output in a frosted embodiment. This 60cm version is built with 4500k color temperature (neutral white) in OEM quality. The LED tube with G13 socket is designed to meet high professional quality demands for long-term stability and luminosity from professional users in offices, industry, offices and retail shops. We only offer LED tubes that can meet these standards. Rotatable end caps: The end covers can be turned by 180 degrees to ensure an optimized orientation of the light source to the object. This offers more flexibility when the tube is installed in a lamp that is mounted on the ceiling or used in Louvre luminaires. In underground car parks the light source can be focused on the parking area.

Shipping from Germany:

We ship from Germany throughout Europe.

Technical consulting and contact: We can offer technical support and consultation. Feel free to get in contact through telephone 0049-221-9924573 during our business hours. You can also send us an e-mail through our contact or get in contact through fax.

Amounts:

Larger quantities of G13 LED-tubes at discounted conditions can be supplied. Please get in contact.

Radiation data:

Light data is available and can be provided to be used in light-planning applications.

Certificates:

CE Certificate certified EMC testing, RoHS Certificate, tested according to EN60825-1 (VDE 0837 part 1) radiation safety laser and LED

Product safety information
color temperature: 3000K Kelvin6000 Kelvin4500k (Kelvin)
average life cycle: minimum 30.000 hours
efficiency in lm/W: 92,1 lm/watt110 lm/watt light output107 lm/watt95 lm/watt91 Lm/Watt
Power supply: 230V / 50 Hz (from 100V up to240V)
dimmable: no
luminous flux: 953 lumen920 lumen1108 lumen951 Lumen1076 lumen
energy efficiency class: A
beam angle: 120° degree
socket fitting: Ja: 180° -Ausrichtung möglich
socket: G13 -T8 socket
colour rendering (CRI): cri: 82RA 83
length: 60cm (588mm)
weight: 220 grams
body: frostedclear
diameter: 26mm
UV. or infrared emission: No
power factor (cos phi): 0.9
Operating hours w. stable lum. flux: min. 20.000 operating hours
power consumpt.: 10 watts
Operat. temperature: -20°C to 65°C
replaces illuminant: 18W fluorescent tube
Additional information:: Limited usage outside of buildings
power input: Single sided
number of switching cycles: > 50.000
Product category: LED-T8 tubes

Can you really save electricity costs, buying a 40 Euro LED-tube compared to a 3 Euro fluorescent tube?

Yes! Especially in companies with long operating times of the lamps.It does not matter whether it is a company with 2 -or 500 employees. Efficiency criteria of T8 or T5 LED tubes are the daily operating-time (uptime or opening hours in retail), the much longer life of LED tubes but also the lower maintenance expense.

Power saving LED tube: 50% or more are possible.

The four standard sizes of fluorescent tubes roughly achieve the following savings:

length power consumption LED-tube consumption LED-tube savings often used in
60cm 18Watt / unit* 9 watts around 50% louvre luminaires
90cm 30 watts/unit* 15 watts around 50% furniture and cabinets
120cm 36 watts/unit* 18-19watts around 50% office, shop, retail, commercial
150cm 58 watts/unit * 22-23 watts around 60% industry and commercial environment.

*The classic fluorescent lamp is always operated in conjunction with a ballast (SG **, ** ECG, CCG **). This consumes additional power and that can account for up to 15 watts per bulb. In the simple replacement of fluorescent lamp with SG against a LED tube, the ballast will continue to operate. It may be more economical to replace the entire lamp.

A personal and professional calculation is necessary. Also helpful is the demonstration of possible alternatives. Please get in contact...

** CCG = Conventional ballast (choke), SG = low loss ballast, Electronic ballast (ECG)

Picture shows result after replacement of 58W fluorescent tubes against 25W LED bulbs. 50% energy saving and a better, high contrast light quality

Life with 24-hour continuous use: 3-4 years

A normal fluorescent lamp has an average life time of about 10,000-12,000 hours. LED tubes are usually indicated with 50,000 hours or more.This is also true for the individual LEDs installed. Realistically, is an average life between 30,000-40,000 hours.This is due to the built-in electronic components (capacitors / triacs) that are subject to a quicker wear.

With very cheap LED tubes downtimes after 2-3 months can often be observed. Get advise from a competent contact person, before you purchase.

Amortization: Between 1.5-3 years is normal.

In the commercial sector with weekly working hours from 40 hours to 24-hour shift system can be quite short payback periods of 1-3 years to achieve and achieve an attractive return on the investment thereafter.

In many cases, the power savings is higher than the monthly burden of financing the conversion.

image shows replacement of 58W fluorescent tube against 25W LED tubes. Lower power consumption and better light with higher contrasts.

It can be assumed that the price of electricity continues to rise in the future and the calculation thus continued to develop positively. An accurate inventory of existing lighting is important. This is associated with some effort, but it pays to be very working basis.

Individual payback calculation for your LED project.We create amortization calculations for LED projects for our customers based on their current situation, operating times and electricity pricesPlease contact us and judge us according to your individual requirements. You can reach us at 0049-221-9924573 or via our contact form

LED tubes are high-priced: We wait with the purchase!

Without a doubt, rethinking is required! The change of the fluorescent tube as a pure consumables towards greater investment must be explained to the companies. Even with declining LED prices and better products, it is not worth waiting. With the currently high electricity prices, great savings can be achieved, which can eventually pay for itself. An investment in the latest technology allows you to lift a high savings now.

Are the LED tubes amortized and have achieved a significant return, you can you still invest in the next-generation of LEDs.

No delay and switching stability: Fast light without flickering

Compared to the classical fluorescent tube LED Tube will start immediately. Without delay and flicker. Flickering neon lights interfere with the visual perception and have a direct negative impact on the quality of work.Through the direct start, it is also possible to operate the LED tubes directly on a motion detector, because the light is available immediately at full intensity. In addition, LED tubes are insensitive to frequent switching on and off. Even the familiar humming and disturbing noise does not occur with LED tubes.

Without UV light / IR component: Protects goods and goods in the salesroom

LED tubes as a replacement for fluorescent lamps produce no ultraviolet light component. This means that goods, clothing or food do not fade in the retail or age faster. In addition, fewer insects are attracted by LED tubes.

Lower maintenance costs

Through the use of LED tubes also reduce maintenance costs, quite worthy to be in larger companies.The frequent exchange of individual tubes or starters omitted. This includes the robustness of the LED tubes. Compared to the fluorescent housing are better protected against shocks or vibration and not break so easily.Advantages and quality criteria for selecting LED-tubes: Get a competent advice. Cologne Energy LED technolog from Cologne

No toxic substances: No bad conscience

Compared to fluorescent LED tubes are not filled with polluting gases to be expensively disposed over the hazardous waste. LED tubes are simply disposed of as electronic waste.

Performance-based electricity bill: base load reduction, power factor and reactive power

For companies with high power consumption is usually not charged per kilowatt-hour special on a performance-based measure of utility. It is calculated with the retrieved peak load, which is calculated mostly from the mean of the two monthly peaks.

With a consistent transition to LED lower your base load permanently.

In companies with a high percentage of machines, the reactive current issue comes into play. The reactive current is compared to the active current provided by the electricity company but can not be used. But it must be paid for it if the factor cos phi is <0.9.

This will be listed separately on the electricity bill. Good LED bulbs have a power factor> 0.95 and are not covered.Traditional fluorescent tubes with CCG have a power factor of 0.3-0.4 and usually have to be compensated by additional capacitors.Large savings and better light. Save 50% and more electricity costs, replacing fluorescent tubes against LED-Tubes

Especially in large commercial machines the theme parks reactive current is an important issue to massively save on electricity costs. Which LEDs are right for my business and what must be considered when upgrading? Please contact us and judge us according to your individual requirements. You can reach us at 0049-221-9924573 or via our contact form

Links:

Wikipedia reactive current

Contact data No title Ms Mr Title - optional First name - optional Last name Company - optional E-Mail Phone - optional Question about item Your question Spam-Schutz wird geladen Close  Absenden Submit question

Download pdf-Datei T8 LED-Röhre neutralweiß klar

PDF Download pdf-Datei T8 LED-Röhre neutralweiß klar

PDF-Datei T8 LED-Leuchtstoffröhre 60cm neutralweiß matt

PDF PDF-Datei T8 LED-Leuchtstoffröhre 60cm neutralweiß matt

PDF-Datei T8 LED T8 Röhre kaltweiß 6000K (matt)

PDF PDF-Datei T8 LED T8 Röhre kaltweiß 6000K (matt)

PDF-Datei T8 LED T8 Röhre kaltweiß 6000K (klar)

PDF PDF-Datei T8 LED T8 Röhre kaltweiß 6000K (klar)

light data *,ies file for 60cm T8 LED tube clear

Download der -ies Lichtdatei für T8 LED-Röhre 60cm in klarer Ausführung

light data *,ies file for 60cm T8 LED tube clear

Download .ldt light data file for T8 LED tube 60cm clear version

LDT Lichtdatei für 60cm T8 LED-Röhre herunterladen

Download .ldt light data file for T8 LED tube 60cm clear version

Others also bought: 2x 600mm T8 LED batten light fitting 2x 600mm T8 LED batten light fitting 9,11 € * 4 ft LED batten fitting 4 ft LED batten fitting 10,41 € * Out of stock 600mm T8 LED batten fitting 600mm T8 LED batten fitting 8,56 € * Out of stock 90cm T8 LED batten light fitting 90cm T8 LED batten light fitting 9,11 € * Similar items T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W 25,53 € * T8 G13 LED tube 60cm 10W 6000K clear 107 Lm/W T8 G13 LED tube 60cm 10W 6000K clear 107 Lm/W 25,53 € * Top T8 LED tube 60cm 10W 6000K  95 Lm/W T8 LED tube 60cm 10W 6000K 95 Lm/W 25,53 € * T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W T8 G13 LED tube 60cm 10W 4500K frosted 92Lm/W 25,53 € * Categories Categories
    • Ultra-slim side emitting PANELS
    • LED panel computer workspace
    • LED Panel 60 x60cm
    • LED Panels 620 x 620mm
    • LED panels 1200 x300mm
    • LED Panel 1200x600
    • LED Panel CRI90
    • LED Panel with IP protection class
    • LED Panel 300 x 300mm
    • surface mounted LED-panel lights
    • mounting- frame for LED-panels
    • Round LED-Panel lights
    • LED power supplies and LED drivers
    • LED panel with stainless steel framing
    • LED Einbauleuchten Economy
    • LED Downlights UGR<19
    • Easy Fit LED Downlights
    • LED Downlights w. IP protection
    • LED Downlights DALI
    • LED recessed spotlight swivelling
    • Black LED recessed spotlights
    • LED recessed spotlight silver reflector
    • LED recessed spotlights for large hole diameters
    • Accessories for LED Downlights
    • small flat LED ceiling spotlights
  • DALI lamps and DALI luminaires
    • 150cm T8 LED batten fitting
    • 120cm T8 LED light fixtures
    • T8 LED light fixtures 90cm
    • LED fluorescent tube fixtures 60cm
    • LED batten fittings with tubes
    • DALI hall luminaires and DALI hall lighting
    • LED high bay fixtures
    • Lighting control and accessories for LED hall spotlights
  • LED office lamps and LED office light
  • LED tubes
    • 1500mm LED tubes
    • 1200mm LED tubes
    • High-Power 30W LED tubes
    • 600mm LED tubes
    • 900mm LED tubes G13
    • LED tube IP67 / IP65
  • LED Floor Lamps
    • Basic lighting for 3 phase track rail systems
    • Accessories CRI90 LED track lights
    • 5ft moisture-proof LED tube fixtures
    • 4ft moisture-proof LED tube fixtures
    • 60cm moisture proof LED tube fitting
    • LED IP65 battens with LED tubes
    • LED Feuchtraum Wannenleuchten mit Bewegungsmelder
    • IP6x moisture proof lamps with LED stripes
    • Vandal proof LED battens
      • Zubhör LED Decklenleuchten
    • Round LED ceiling light with interchangeable reflector
  • LED Floodlights
  • hygienic LED panels
    • T8 LED quick installation system
    • LED workshop ceiling luminaire
    • commercial workspace lighting
    • LED E27 lamp
    • LED GU 10 lamp
    • LED GU 5.3 lamp
    • LED E14 lamp
    • LED G9 lamps
    • LED G4 lamp
    • Housing for GU10 spotlights
  • Remainders and sample lights
  • Air purifying lamps with UV-C light
  • LED power supplies / LED drivers
Special offers Sale 32% LED spotlight 50W for the illumination of commercial... 50W LED High bay light 58,08 € - 63,13 € * Old price: 63,13 € Sale 26% New and efficient LED spotlight dimmable with IP65... 85mm LED spot Dimmable IP65 OSRAM® Leds 70mm hole size adjustable light colour 14,68 € * Old price: 19,86 € Sale 20% 116mm LED reflector Downlight UGR<19 3000K 1-10V dimming 116mm LED reflector Downlight UGR<19 3000K 1-10V dimming 44,90 € - 56,20 € * Old price: 56,20 € Information Information
  • News
  • LED projects and references
  • payment & shipping
  • Our services
  • About us
  • Sitemap
  • LED Innenbeleuchtung
  • LED Röhrenfassungen und Deckenleuchten

Từ khóa » T8 G13 60 Cm