1P, 1P+N and 2P circuit breakers are all used for the control and protection of single-phase power circuits. So what is the difference between them and the application effect?
1. Definition of 1P, 1P+N and 2P circuit breakers
- 1P circuit breaker — single-pole circuit breaker, with thermal tripping function, can only control live wire (phase wire), modulus 18mm;
- 1P+N circuit breaker — single-pole +N circuit breaker, which controls the live wire and the neutral wire at the same time, and only the live wire has the thermal trip function; the modulus is 18mm;
- 2P circuit breaker — 2-pole circuit breaker, which controls both the live wire and the neutral wire at the same time, with thermal tripping function, the modulus is 2*18mm=36mm;
2. Application of 1P, 1P+N and 2P circuit breakers
- Application of 1P circuit breaker: From the perspective of total economic cost, if the upper-level circuit breaker has a leakage trip function, and at least the incoming line (or the upper level of the outgoing line) is equipped with a leakage circuit breaker, the 1P circuit breaker can be selected, but Note that the superior power supply must be cut off during maintenance to prevent accidents caused by disordered live and neutral wires.
- Application of 1P+N (ie DPN) circuit breaker: To avoid the problems encountered by 1P circuit breakers during maintenance.
- Application of 2P circuit breaker: For the 1P and 1P+N circuit breakers with the same modulus of 18mm, because of the important influence of the space size, the "limit breaking capacity" of the former must be higher than the latter under the condition of short circuit accident . For the same reason, for some more important occasions, such as frequent maintenance and operation or power circuits that are prone to failure, it is better to use 2P circuit breakers (higher cost)
Related
Protection characteristics of low-voltage circuit breakers
Inter-stage coordination of low-voltage circuit breaker selection
Definition and classification of low-voltage circuit breakers
Main features of oily circuit breaker
Products ACB MCCB ATS MCB HMCB | Blog Company Industry FAQs Technology | About Nader R&D Platform Quality Platform Manufacturing | Address:No.2000, South ShenJiang Road, Pudong New Area Tel:+86-21-68586719 Email:rfq@nader-circuit-breaker.com |
Từ khóa » Cb 1p Và 2p
-
Sự Khác Nhau Giữa CB 1P Và CB 2P? - Dien Tu Viet Nam
-
MCB Là Gì? Cách Lựa Chọn MCB Cho Gia đình
-
MCB Là Gì? Phân Loại-cấu Tạo-ứng Dụng(MCB 1P - 2P - 3P - KHS 247
-
Ý Nghĩa Của Cb 2p Và 1p - Toàn Thua
-
Sự Khác Nhau Giữa CB 1 Cực Và CB 2 Cực - Thiết Bị Điện Kiên Vương
-
Sự Khác Nhau Của MCB 2P Và 1P+N - Thiết Bị Điện Công Nghiệp
-
Cho Hỏi Sự Khác Nhau Của MCB 2p Và 1p+N - WebDien
-
Cầu Dao Tép 1P 2P Và CB Cóc Panasonic | Shopee Việt Nam
-
CB Tép 1P, 2P, 3P, 4P HITACHI Dòng định Mức 6A, 10A, 16A, 20A ...
-
Aptomat Là Gì - Điện Tuấn Lộc Phát
-
What Is The Difference Between 1P, 2P, 3P And 4P? How To Choose?
-
Mcb 2P Là Gì - Cách Chọn Mcb Tốt Nhất
-
Cấu Tạo Và Nguyên Lý Hoạt động Của Aptomat MCB