Three-phase Power Analyser CVM-C4-ITF-485-ICT2 - Circutor
Có thể bạn quan tâm
- Share
- PDF Datasheet






CVM-C4-ITF-485-ICT2
CVM-C4-ITF-485-ICT2, Power analizer, panel mounted 96x96
Code: M52706.
- Protocol: Modbus/RTU
- Communications: RS-485
- Transistor output: 2
- Nº relays: 2
- Digital inputs: 2
- Measuring current Channels: 3
- Input current: .../5 A | .../1 A
- Mounting: Pannel
- Information
- Specifications
- Dimensions
- Connections
- Videos
- Downloads
- Accessories
- Support
INFORMATION
Description
CVM-C4 is a power analyser that measures, calculates and displays the main electrical parameters for single-phase and three-phase networks (with or without neutral) on its screen. Measurement is made in true rms value, by means of 3 AC voltage inputs and 3 /5 A or /1 A current inputs. Relay outputs enable local operation in the event of an alarm event being triggered. Its dimensions are 96 x 96 mm with a depth of only 41.5 mm. Current measurement is indirectly carried out by /5A or /1A transformers. It allows AC (80...270 Vac)and DC (80...270 Vdc or 18... 36 Vdc power supply systems). It features RS-485 communications enabling remote data readout or Scada or Master centralisation.
Applications
- For electrical parameter measurement in areas whose reduced dimensions require the installation of a space-saving panel analyser.
- Instantaneous value measurement of electrical parameters with communications.
- Logging of consumed or generated Active or Reactive Energy.
- The device's relay outputs allow the installation to be locally operated.
- Programmable alarms by setting relay activation time, connection delay and hysteresis.
- 5000 imp/kWh energy impulse outputs
- Energy measurement of two different sources on 2 separate meters (by digital input activation).
- Voltage and current THD% measurement to check for harmonics in the installation.
Do you need more information about this product?
If you have any questions, let's talk.
Talk to a specialistSPECIFICATIONS
AC power supply
Nominal voltage80 ... 270 VacFrequency50/60 HzConsumption6 … 18 VAInstallation categoryCAT III 300 VDC power supply
Nominal voltage80…270 VdcConsumption1.5 ... 1.8 WInstallation categoryCAT III 300 VVoltage measurement circuit
Nominal voltage100…277 V~ Ph-N (± 8%)Frequency measuring range45…65 HzInput impedance> 1.7 MΩMinimum measurement voltage (Vstart)10 VMaximum permanent measurement voltage1.2 Un continuous, 2 Un instantaneous (1 min)Consumption< 0.2 VA (por fase)Installation categoryCAT III 300 VSampling frequency45…65 HzCurrent measurement circuit
Nominal current (In)1 A / 5 A ~Allowable overload1.2 In continuous, 10 In instantaneous(5s)Consumption< 0.2 VA (por fase)Installation categoryCAT III 300 VMeasurement accuracy
Phase voltage measurement0.2 %Phase current measurement0.2 %Frequency measurement0.5 %Active power measurement (kW)0.5 %Reactive power measurement (kvar)0.5 %Active energy measurement (kWh)0.5 %Reactive energy measurement (kvarh)0.5 %Digital transistor outputs
TypePassive impulseMaximum voltage27 VccMaximum current27 mAMaximum frequency10 HzPulse widthMinimum pulse width: 80mADigital relay outputs
TypeRelayQuantity2Maximum open contact voltage277 V ~ / 30 VdcMaximum current5 A ~Resistive load (max.)250 Vca / 5 Aca, 30 Vcc / 5 AccElectrical life(250 V ~ / 5 A) 1 x 105Maximum switching capacity1385 VA / 150 WDigital inputs
Quantity2TypePotential-free contactInput/output insulation3,75 kV RMSMaximum short-circuit current4 mAMaximum open circuit voltage30 VSerial communication
Technology / TypeRS-485User interface
Display typeLCDKeyboard3 keysEnvironmental characteristics
Working temperature-10 … +60 ºCStorage temperature-20 … +70 ºCRelative humidity (without condensation)5 … 95%Protection classFront: IP54, Rear: IP20Mechanical characteristics
EnvelopePolycarbonate + ABSWeight (kg)0,268Size (mm) width x height x depth96 x 96 x 41.5 (mm)Standards
StandardsIEC 61010-1, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11Electrical safety, Installation categoryCAT III 300 VElectrical safety, Contamination level/classPollution resistance 2Electrical safety, Maximum height (m)2000DIMENSIONS
CONNECTIONS
VIDEOS
DOWNLOADS
User's manual EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Technical guide EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico 3D EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Dimensions EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Diagram connection EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Datasheet EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico CE-certified EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Other Certificates EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Software & Firmware EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico LeafletACCESORIES
SUPPORT
Contacta con nosotros
Envíanos tu consulta y contactaremos contigo.
¿Quieres comprar?
Contacta con nuestra red comercial o busca tu distribuidor cercano.
TAMBIÉN TE PUEDE INTERESAR

CVM-B
Power analyzer, colour display, panel mounted

PowerStudio_4x (Legacy)
Energy management software (Legacy)
CONTACT
Vial Sant Jordi s/n – 08232 Viladecavalls, Barcelona (Spain) +34 93 745 29 00 Contact
SAT
After-Sales and Technical Assistance +34 93 745 29 19 Send enquiry
EXPERTS IN
- Electrical energy efficiency
- Harmonic filtering
- Electrical protection
- Energy measurement
- Self-consumption
- Energy audit
- Internet of Things
PRODUCTS
- Measurement and control
- Metering
- Protection and control
- Power factor correction and harmonic filtering
- Renewable energies
- Software
- Industrial IoT and Automation
CONNECT
INFORMATION
- Privacy policy
- Cookies policy
- Use of social networks
- General conditions of sale
- Legal notice
- Code of ethics
© 2024 CIRCUTOR.COM | All rights reserved.
Từ khóa » Cvm-c4
-
[PDF] INSTRUCTION MANUAL - Circutor
-
Circutor CVM-C4 (CT) Settings - YouTube
-
Circutor CVM-C4 Series Manuals - ManualsLib
-
CIRCUTOR CVM-C4 SERIES INSTRUCTION MANUAL Pdf Download
-
Circutor CVM-C4 Multi-function Datasheet - Manualzz
-
Circutor CVM-C4 Multi Function Panel Mount Multimeter
-
M52706 CVM-C4 Electric Multimeter With Panel, 5 X 9.6 X ... - Amazon
-
Rotax Limited - CVM-C4 Is A Power Analyzer That Measures ...
-
Circutor CVM-C4 Series User Manuals PDF Download
-
Analizador De Redes CVM-C4-ITF-485-ICT2 | Olus
-
Paket Power Meter (CVM-C4 (Circutor)1 Pcs Dan CT (CIC) (50-800 ...
-
CVM C4, Analyseur De Réseaux Pour Panneau - Elektra
-
Circutor CVM-C4-ITF-485-ICT2 - Ulrich Matter AG