Additional power dissipation caused by actuators (resistive) [W]
-
Certifications
CE
Yes
UKCA
Yes
ATEX
Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X
UL
cULus E115267Industrial control equipment
HazLoc
cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5
DNV
Temperature: B (0 to 55°C)Humidity: B (up to 100%)Vibration: B (4 g)EMC: B (bridge and open deck)
CCS
Yes
LR
ENV1
KR
Yes
ABS
Yes
BV
EC33BTemperature: 5 - 55°CVibration: 4 gEMC: Bridge and open deck
KC
Yes
Interfaces
Fieldbus
POWERLINK (V1/V2) controlled node
Type
Type 2
Variant
2x shielded RJ45 (hub)
Line length
Max. 100 m between 2 stations (segment length)
Transfer rate
100 Mbit/s
Transfer
Physical layer
100BASE-TX
Half-duplex
Yes
Full-duplex
No
Autonegotiation
Yes
Auto-MDI/MDIX
Yes
Hub propagation delay
0.96 to 1 µs
Min. cycle time
Fieldbus
200 μs
X2X Link
200 μs
Synchronization between bus systems possible
Yes
Electrical properties
Electrical isolation
POWERLINK isolated from bus and I/O
Operating conditions
Mounting orientation
Horizontal
Yes
Vertical
Yes
Installation elevation above sea level
0 to 2000 m
No limitation
>2000 m
Reduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529
IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation
-25 to 60°C
Vertical mounting orientation
-25 to 50°C
Derating
-
Storage
-40 to 85°C
Transport
-40 to 85°C
Relative humidity
Operation
5 to 95%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical properties
Note
Order 1x terminal block X20TB12 separately. Order 1x power supply module X20PS9400 or X20PS9402 separately. Order 1x bus base X20BB80 separately.
Pitch
37.5+0.2 mm
Material number:
X20BC0083
Description:
POWERLINK
I/O configuration and firmware update via the fieldbus
Integrated hub for economical wiring
The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler.
POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.
Mandatory Accessories
System modules for bus controllers
X20BB80
X20 bus base, for X20 base module (BC, HB, etc.) and X20 power supply module, X20 end cover plates (left and right) X20AC0SL1/X20AC0SR1 included
X20PS9400
X20 power supply module, for bus controller and internal I/O power supply X2X Link power supply
X20PS9402
X20 power supply module, for bus controller and internal I/O power supply, X2X Link supply, supply not galvanically isolated