XN-450 - Sysmex

Có thể bạn quan tâm

XN-450

  1. Home
  2. XN-L Series
  3. XN-450
Awaiting product image
XN-450 Category: XN-L Series
  • Share this product
  • More Information

Automated compact 6-part differential haematology analyser. With the XN-450 you can run single samples safely in closed mode. It has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen that makes it easy to operate.

Coagulation analysers

XN-450

  • Compact 6-part differential analyser

  • Throughput of 70 samples per hour

  • Single sample analysis in closed mode

  • Fully integrated IPU including LCD colour touchscreen

  • Only 25 µL aspiration volume in whole blood mode

  • More than just CBC + DIFF – added clinical values available

  • Best-in-class diagnostics tailored to small and mid-sized laboratories

  • Features & Benefits
  • Specifications
  • Documents

With the XN-450 you can run single samples safely in closed mode. The compact 6-part differential analyser has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen – so you do not need a separate computer to operate the analyser. It incorporates the proven Sysmex technologies of fluorescence flow cytometry, hydrodynamic focussing and our cyanide-free SLS method for determining haemoglobin. Ready for the future beyond just CBC + DIFF, it can be upgraded by adding new clinical and productivity values.

Dimensions / weights
  • W x H x D [mm / kg]
  • XN-450: 450 x 440 x 460 / approx. 35 kg
Throughput
  • CBC + DIFF: up to 70 samples/hour
  • CBC + DIFF + RET: up to 35 samples/hour
  • Body fluide mode: up to 30 samples/hour
Aspiration volume
  • 25 µL in WB / Low WBC mode,
  • 70 µL in PD and BF mode
Analysis parameters
  • Whole Blood WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%
  • With RET (optional) RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O, IPF#, IPF, RBC-He, Delta-He, HYPO-He, HYPER-He
  • Body Fluids (optional) WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#
Measurement principles
  • WBC DIFF/RET: Fluorescence Flow Cytometry
  • WBC: Flow Cytometry
  • RBC/PLT: DC Impedance method with hydrodynamic focusing
  • HGB: Cyanide-free SLS method
Data storage capacities
  • Results: 100,000 samples
  • Patient information: 10,000 records
  • Calibration history: 20 times/ module
  • QC files: 99 files including XbarM
  • QC plots: 300 plots / file
User maintenance
  • Daily shutdown
  • Weekly cleaning sequence with Cellclean or Cellclean Auto
null

XN-L brochure

Download Here » Features & Benefits

With the XN-450 you can run single samples safely in closed mode. The compact 6-part differential analyser has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen – so you do not need a separate computer to operate the analyser. It incorporates the proven Sysmex technologies of fluorescence flow cytometry, hydrodynamic focussing and our cyanide-free SLS method for determining haemoglobin. Ready for the future beyond just CBC + DIFF, it can be upgraded by adding new clinical and productivity values.

Specifications
Dimensions / weights
  • W x H x D [mm / kg]
  • XN-450: 450 x 440 x 460 / approx. 35 kg
Throughput
  • CBC + DIFF: up to 70 samples/hour
  • CBC + DIFF + RET: up to 35 samples/hour
  • Body fluide mode: up to 30 samples/hour
Aspiration volume
  • 25 µL in WB / Low WBC mode,
  • 70 µL in PD and BF mode
Analysis parameters
  • Whole Blood WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%
  • With RET (optional) RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O, IPF#, IPF, RBC-He, Delta-He, HYPO-He, HYPER-He
  • Body Fluids (optional) WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#
Measurement principles
  • WBC DIFF/RET: Fluorescence Flow Cytometry
  • WBC: Flow Cytometry
  • RBC/PLT: DC Impedance method with hydrodynamic focusing
  • HGB: Cyanide-free SLS method
Data storage capacities
  • Results: 100,000 samples
  • Patient information: 10,000 records
  • Calibration history: 20 times/ module
  • QC files: 99 files including XbarM
  • QC plots: 300 plots / file
User maintenance
  • Daily shutdown
  • Weekly cleaning sequence with Cellclean or Cellclean Auto
Documents null

XN-L brochure

Download Here »

Useful Links

Products

Contact Info

(+65) 6221 3629

(+65) 6221 3687

[email protected]

9 Tampines Grande, Asia Green, #06-18, Singapore 528735

Social Media

Career Conditions of Sales Terms of use Privacy policy

© Copyright Sysmex Asia Pacific Pte Ltd - 2024 | All rights reserved.

X

You are redirected to a 3rd party website!

Clicking on a social media link implies that you understand you are leaving our site and entering a third-party website. We are not responsible for their content, privacy policies, or terms of use. Please review their terms and privacy policy before proceeding. We do not endorse or control the third-party website and disclaim any liability for damages or consequences.

We use cookies

This website uses cookies to ensure that you get the best experience on our website. By clicking "Agree", you consent to our use of cookies. Please refer to our Privacy Policy.
Agree

Từ khóa » X N